Pepperl Fuchs PS1000-D2-24.20.RM
Redundancy Module
- MPN
- PS1000-D2-24.20.RM
- Category
- Industrial Power Supplies
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs PS1000-D2-24.20.RM?
24 V DC to 28 V DC input
2 inputs with 1 output
Output 24 V DC, 20 A
Housing width 32 mm
Built-in decoupling mosfets for 1+1 and N+1 redundancy
Automatic load sharing
Reverse input polarity protection
Easy wiring: distribution terminal for negative pole included
Redundancy status indicator
Suitable for Zone 2/Div. 2 mounting
24 V DC to 28 V DC input, 2 inputs with 1 output, Output 24 V DC, 20 A, Housing width 32 mm, Built-in decoupling mosfets for 1+1 and N+1 redundancy, Automatic load sharing, Reverse input polarity protection, Easy wiring: distribution terminal for negative pole included, Redundancy status indicator, Suitable for Zone 2/Div. 2 mounting, Device type: device for DIN rail mounting, Function: Redundancy Module, Voltage range: 24 ... 28 V DC
Specifications
Electrical specifications
| Order code (Pepperl+Fuchs part number) | 70103527 |
| Voltage drop | input to output 0.1 ... 0.5 V at input 2 x 5 A 0.2 ... 0.5 V at input 2 x 10 A 0.24 ... 0.5 V at input 2 x 12 A load share dependent |
| Power dissipation | 1.7 W no load 2.6 ... 4.7 W at input 2 x 5 A 5.6 ... 8.7 W at input 2 x 10 A |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Input
| Rated voltage | 24 ... 28 V Ur |
| Voltage range | 18 ... 35 V DC |
| Current | 2 x 12 A at ambient temperature 2 x 10 A at ambient temperature 70 °C (158 °F) 2x 17 mA for max. 5 s for lower output currents see technical information |
Output
| Voltage range | 24 ... 28 V DC |
| Current | 24 A at ambient temperature 20 A at ambient temperature 32.5 A for max. 5 s max. 26 A in overload or short circuit mode (voltage < 6 V DC) |
Fault indication output
| Connection | terminals 13, 14 : relay contact load share terminals 23, 24 : relay contact redundancy |
| Output type | relay contact load share - contact is closed if the adjustment of the output voltages are sufficient - contact is open if an even load share does not occur and readjustment of the output voltage is required relay contact redundancy - contact is closed if no fault is detected - contact is open if one or both input voltages are below 22 V DC or above 30 V DC - contact is open if the output current is higher than the adjusted value of the output current - contact is open if an internal defect of the device is detected |
| Contact loading | max. 60 V DC/0.3 A ; 30 V DC/1 A ; 30 V AC/0.5 A resistive load min. 1 mA at 5 V DC |
Galvanic isolation
| Input/Output | SELV/PELV |
Indicators/settings
| Display elements | LED green: output status - LED lights up if the output current is smaller than the adjusted value of the output current LEDs green: load share status - LEDs indicate the load share status between the two power supplies LED green: redundancy status - LED lights up if no fault is detected - LED flashes if one ore both input values are below 22 V or above 30 V - LED flashes if the output current is higher than the adjusted value of the output current - LED flashes if an internal defect is detected |
| Control elements | rotary switch |
| Configuration | setting of the output current via rotary switch - switch setting to 5 A in combination with two 5A power supplies (1+1 redundancy) - switch setting to 10 A in combination with two 10A power supplies (1+1 redundancy) - switch setting to 20 A for N+1 redundant systems |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | IEC/EN 61000-6-1 , IEC/EN 61000-6-2 , IEC/EN 61000-6-3 , IEC/EN 61000-6-4 |
| Low voltage: Directive 2014/35/EU | EN 61010-1 |
| RoHS: Directive 2011/65/EU (RoHS) | IEC/EN 63000:2019 |
Conformity
| Degree of protection | EN 60529 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
Ambient conditions
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) , see technical information |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 5 ... 95 %, non-condensing |
| Shock resistance | 20 g , 11 ms or 30 g , 6 ms |
| Vibration resistance | 2 ... 17.8 Hz : ± 1.6 mm , 17.8 ... 500 Hz : 2 g |
Mechanical specifications
| Housing material | aluminum alloy , galvanized steel |
| Degree of protection | IP20 |
| Connection: Input/Output | screw terminals conductor cross section: max. 6 mm2 (AWG 20-10) cable diameter: max. 2.8 mm, wire end ferrules included stripped insulation length: 7 mm tightening torque: max. 0.8 Nm |
| Connection: Relay contact output | spring terminals conductor cross section: max. 1.5 mm2 (AWG 24-16) cable diameter: max. 1.6 mm, wire end ferrules included stripped insulation length: 7 mm |
| Mass | approx. 310 g |
| Dimensions | 32 x 124 x 117 mm (W x H x D) , without DIN mounting rail |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| ATEX approval: ATEX certificate | EPS 11 ATEX 1 312 X |
| ATEX approval: ATEX marking | II 3G Ex ec nC II T4 Gc |
| Directive conformity: Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-7:2016 , EN 60079-15:2010 |
International approvals
| UL approval | E223176 |
| IECEx approval: IECEx certificate | IECEx EPS 20.0057X |
| IECEx approval: IECEx marking | Ex ec nC IIC T4 Gc |
| IECEx approval: Standards | IEC 60079-0:2011 , IEC 60079-7:2015 , IEC 60079-15:2010 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
PS1000-D2-24.20.RM: frequently asked questions
When can PS1000-D2-24.20.RM be shipped?
PS1000-D2-24.20.RM is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up PS1000-D2-24.20.RM in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for PS1000-D2-24.20.RM and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PS1000-D2-24.20.RM, subject to availability and destination.