What is the Pepperl Fuchs LVL-A7-AG1A-E5V1-CG-EMS?
Limit switch for liquids
Process connection G1/2
Suitable for process temperatures up to 100 °C (212 °F)
Rugged stainless steel housing
Onsite function check possible thanks to LED indication
External function test with test magnet
Limit switch for liquids, Process connection G1/2, Suitable for process temperatures up to 100 °C (212 °F), Rugged stainless steel housing, Onsite function check possible thanks to LED indication, External function test with test magnet
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 275573-100021 |
| Measuring method | The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid. |
| Construction type | compact device |
| Operating mode | MAX = maximum safety: The device keeps the electronic switch closed as long as the liquid level is below the fork. example application: overspill protectionMIN = minimum safety: The device keeps the electronic switch closed as long as the fork is immersed in liquid. example application: dry running protection of pumpsThe electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle) |
| Series | LVL-A* |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Supply
| Connection | This device may be used with any sequential circuit, as long as the circuit can support the electrical circuit values of the switching elements. |
| Rated voltage | 10 ... 35 V DC Ur |
| Fusing | external 500 mA slow |
| Current consumption | < 15 mA |
| Power consumption | 975 mW |
| Residual ripple | 5 V ss at 0 ... 400 Hz |
Input
| Measured variable | density |
| Measuring range | min. 0.7 g/cm3 |
Output
| Output type | switching output |
| Switching current | max. 250 mA |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 |
| Electromagnetic compatibility: Directive 2004/108/EC | EN 61326-1:2006 , EN 61326-2-3:2006 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-64 |
| Climate class | DIN EN 60068-2-38/IEC 68-2-38 |
Measurement accuracy
| Reference operating conditions | - ambient temperature: 25 °C (+77 °F) - process pressure: 1 bar (14.5 psi) - fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s) - medium temperature: 25 °C (+77 °F) - density setting: > 0.7 g/cm3 - switching time delay: standard (0,5 s, 1 s) |
| Measured value resolution | < 0.5 mm |
| Measuring frequency | approx. 1100 Hz in air |
| Switching point | 13 mm ± 1 mm |
| Non-repeatability | ± 1 mm acc. to DIN 61298-2 |
| Hysteresis | max. 3 mm |
| Influence of ambient temperature | negligible |
| Influence of medium temperature | -25 µm/°C |
| Influence of medium pressure | -20 µm/bar |
| Switching time | - 0.5 s when tuning fork is covered - 1.0 s when tuning fork is uncovered |
| Switch-on delay | max. 3 s |
Operating conditions
| Installation conditions: Installation position | see technical information (TI) |
| Ambient conditions: Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Ambient conditions: Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Ambient conditions: Shock resistance | a = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea |
| Ambient conditions: Vibration resistance | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h |
| Process conditions: Medium temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Process conditions: Process pressure (static pressure) | -1 ... +40 bar (-14.5 ... +580 psi) |
| Process conditions: State of aggregation | liquid |
| Process conditions: Density | min. 0.7 g/cm3 |
| Process conditions: Viscosity | 1 ... 10000 mPa/s, dynamic viscosity |
| Process conditions: Solid contents | < ∅5 mm |
Mechanical specifications
| Degree of protection | IP65 / IP67 , NEMA 4X |
| Connection | M12 connector, 4-pin |
| Material | process connection and short tube: stainless steel 316L (1.4401/1.4435) tuning fork: stainless steel 316L housing cover and connector: PPSU |
| Surface quality | Ra < 3.2 µm |
| Mass | approx. 140 g |
| Process connection | thread G1/2 to ISO 228 |
Indication and operation
| Display elements | The LED display is on the connection side. - green LED: indication of ready to operate - red LED: fault indication - yellow LED: operating mode indication |
| Function test | function test with test magnet (optional accessory) |
Certificates and approvals
| CSA approval | cCSAus Listed, General Purpose |
| Overspill protection | see approval (ZE) |
General information
| Supplementary documentation | technical information (TI) manual (BA) approval (ZE) |
| Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Accessories
| Designation | see technical information (TI) |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
LVL-A7-AG1A-E5V1-CG-EMS: frequently asked questions
When can LVL-A7-AG1A-E5V1-CG-EMS be shipped?
LVL-A7-AG1A-E5V1-CG-EMS is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LVL-A7-AG1A-E5V1-CG-EMS in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LVL-A7-AG1A-E5V1-CG-EMS and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LVL-A7-AG1A-E5V1-CG-EMS, subject to availability and destination.
More Pepperl Fuchs parts