What is the Pepperl Fuchs LVL-A7?

Limit switch for liquids

Onsite function check possible thanks to LED indication

Large selection of process connections for hassle-free installation in existing systems

Easy to install even at points difficult to access due to compact design

Rugged stainless steel housing

Cost-saving plug connections

Approval as overfill protection and leak detection system acc. to WHG

Limit switch for liquids, Onsite function check possible thanks to LED indication, Large selection of process connections for hassle-free installation in existing systems, Easy to install even at points difficult to access due to compact design, Rugged stainless steel housing, Cost-saving plug connections, Approval as overfill protection and leak detection system acc. to WHG

Specifications

General specifications

Order code (Pepperl+Fuchs part number)275573
Measuring methodThe tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid.
Construction typecompact device device with short tube
Operating modeMAX = maximum safety: The device keeps the electronic switch closed as long as the liquid level is below the fork. example application: overspill protectionMIN = minimum safety: The device keeps the electronic switch closed as long as the fork is immersed in liquid. example application: dry running protection of pumpsThe electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle)
SeriesVibracon LVL-A7
LifecycleActive (current Pepperl+Fuchs product)

Supply

Rated voltage- DC-PNP: 10 ... 35 V DC, 3-wire - AC/DC: 20 ... 253 V AC/DC, 2-wire Ur
Current consumption- DC-PNP: < 15 mA - AC/DC: < 3.8 mA
Power consumption- DC-PNP: < 975 mW - AC/DC: < 850 mW

Input

Measured variabledensity
Measuring rangemin. 0.7 g/cm3, optional> 0.5 g/cm3

Output

Output typeswitching output
Switching currentmax. 250 mA

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006
Low voltage: Directive 2014/35/EUEN 61010-1:2010

Conformity

Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-64
Climate classDIN EN 60068-2-38/IEC 68-2-38

Measurement accuracy

Reference operating conditions- ambient temperature: 25 °C (+77 °F) - process pressure: 1 bar (14.5 psi) - fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s) - medium temperature: 25 °C (+77 °F) - density setting: > 0.7 g/cm3 - switching time delay: standard (0,5 s, 1 s)
Measured value resolution< 0.5 mm
Measuring frequencyapprox. 1100 Hz in air
Switching point13 mm ± 1 mm
Non-repeatability± 1 mm acc. to DIN 61298-2
Hysteresismax. 3 mm
Influence of ambient temperaturenegligible
Influence of medium temperature-25 µm/°C
Influence of medium pressure-20 µm/bar
Switching time- 0.5 s when tuning fork is covered - 1.0 s when tuning fork is uncovered - other switching times on request

Operating conditions

Installation conditions: Installation positionsee section mounting position
Ambient conditions: Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Ambient conditions: Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Ambient conditions: Shock resistancea = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea
Ambient conditions: Vibration resistancea(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h
Process conditions: Process temperature-40 ... +100 °C (-40 ... +212 °F) -40 ... +150 °C (-40 ... +302 °F)
Process conditions: Process pressure (static pressure)-1 ... +40 bar (-14.5 ... +580 psi)
Process conditions: State of aggregationliquid
Process conditions: Densitymin. 0.7 g/cm3, optional> 0.5 g/cm3
Process conditions: Viscosity1 ... 10000 mPa/s, dynamic viscosity
Process conditions: Solid contents< ∅5 mm

Mechanical specifications

Degree of protection- IP65/IP67, NEMA 4X enclosure (plug M12) - IP65, NEMA 4X enclosure (valve plug) - IP65/68, NEMA 4X/6P enclosure (cable)
Connection- cable 5 m - valve plug NPT1/2 - valve plug QUICKON - valve plug M16 - plug M12
Materialsee technical information (TI)
Surface qualityRa < 3.2 µm
Masssee technical information (TI)
Dimensionssee technical information (TI)
Process connection- thread ISO 228 G1/2, G3/4, G1 - thread EN 10226 R1/2, R3/4, R1 - thread ASME MNPT1/2, MNPT3/4, MNPT1

Indication and operation

Display elementsThe LED display is on the connection side. - green LED: indication of ready to operate - red LED: fault indication - yellow LED: operating mode indication
Function testfunction test with test magnet (optional accessory)

Certificates and approvals

Overspill protectionZ-65.11-554 (overspill protection acc. to WHG) Z-65.40-555 (leak detection system acc. to WHG) If you need the approvals also in paper form, select the option WH in the type code.

General information

Supplementary documentationtechnical information (TI) manual (BA) approval (ZE)
Supplementary informationStatement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Accessories

Designationsee technical information (TI)

LVL-A7: frequently asked questions

When can LVL-A7 be shipped?

LVL-A7 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LVL-A7 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LVL-A7 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LVL-A7, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs LTC57 – Guided Level Radar
Pepperl Fuchs
LTC57

Guided Level Radar

Pepperl Fuchs LUC-M10 – Ultrasonic Level Sensor
Pepperl Fuchs
LUC-M10

Ultrasonic Level Sensor

Pepperl Fuchs LUC-M20 – Ultrasonic Level Sensor
Pepperl Fuchs
LUC-M20

Ultrasonic Level Sensor

Pepperl Fuchs LUC-M40 – Ultrasonic Level Sensor
Pepperl Fuchs
LUC-M40

Ultrasonic Level Sensor

Pepperl Fuchs LVL-A7H – Vibration Limit Switch
Pepperl Fuchs
LVL-A7H

Vibration Limit Switch

Pepperl Fuchs LVL-A7Price and lead time confirmed within 1 business day
Request a Quote