Pepperl Fuchs KFU8-UFT-2.D.FA

Frequency Converter with Direction and Synchronization Monitor

MPN
KFU8-UFT-2.D.FA
Price and lead time confirmed within 1 business day

Discontinued by Pepperl Fuchs — we can still source the original KFU8-UFT-2.D.FA (new, used or refurbished, subject to availability). Request a quote below.

Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs KFU8-UFT-2.D.FA?

2-channel signal conditioner

Universal usage at different power supplies

Dry contact or NAMUR inputs

Input frequency 1 mHz ... 1 kHz

Current output 0/4 mA ... 20 mA

Relay contact and transistor output

Start-up override

Configurable by PACTware or keypad

Line fault detection (LFD)

2-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz, Input I, II: 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact, Output I, II: signal, relay, Output V: analog

Pepperl+Fuchs has archived the KFU8-UFT-2.D.FA: it is no longer part of the current range, and Pepperl+Fuchs names KFU8-UFT-2.D as its successor. PartnerPLC sources discontinued Pepperl+Fuchs parts on the surplus market for maintenance and repair of existing installations — request a quote for availability, condition, price and lead time.

Specifications

General specifications

Order code (Pepperl+Fuchs part number)192334
Signal typeDigital Input
LifecycleDiscontinued — archived by Pepperl+Fuchs; successor KFU8-UFT-2.D

Supply

Connectionterminals 23, 24
Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Ur
Rated currentapprox. 130 mA Ir
Power dissipation2.2 W / 3.5 VA
Power consumption2.5 W / 4 VA

Interface

Programming interfaceprogramming socket

Input

Connection sidefield side
Connectioninput I: terminals 1+, 3- input II: terminals 4+, 6- input III: terminals 13+, 14- (control input 1) input IV: terminals 15+, 14- (control input 2)
Input I, II2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
Open circuit voltage/short-circuit current8.2 V / 10 mA
Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA
Pulse durationmin. 250 µs , overlap on direction of rotation signal: ≥ 125 µs
Input frequencyrotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz
Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA
Input III, IV: Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA
Input III, IV: Open circuit voltage/short-circuit current18 V / 5 mA

Output

Connection sidecontrol side
Connectionoutput I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 19+, 20- output IV: terminals 21+, 20- output V: terminals 7-, 8+
Output I, IIsignal, relay
Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A
Mechanical life5 x 107 switching cycles
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Output III and IVsignal , electronic output, passive
Contact loading40 V DC
Signal level1-signal: (L+) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: blocked output (off-state current ≤ 10 µA)
Output Vanalog
Current range0 ... 20 mA or 4 ... 20 mA
Open loop voltagemax. 24 V DC
Loadmax. 650 Ω
Fault signaldownscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43)
Programming interface: Connectionprogramming socket
Programming interface: InterfaceRS 232

Transfer characteristics

Input I and II: Measuring range0.001 ... 1000 Hz
Input I and II: Resolutionslip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz
Input I and II: Accuracyslip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz
Input I and II: Measuring timefrequency measurement: < 100 ms
Input I and II: Influence of ambient temperature0.003 %/K (30 ppm)
Output I, II: Response delay≤ 200 ms
Output V: Resolution< 10 µA
Output V: Accuracy< 30 µA
Output V: Influence of ambient temperature0.005 %/K (50 ppm)

Galvanic isolation

Input I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, IVreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III, IV/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III, IV/input III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III, IV/Vbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output V/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/output III, IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Indicators/settings

Display elementsLEDs , display
Control elementsControl panel
Configurationvia operating buttons via PACTware
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2006
Low voltage: Directive 2014/35/EUEN 61010-1:2010

Conformity

Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
InputEN 60947-5-6:2000

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Mass300 g
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Height119 mm
Width40 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Downloads & documentation

Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.

Data sheets & manuals

CAD & dimension drawings

Certificates (1)

KFU8-UFT-2.D.FA: frequently asked questions

Can I still buy the KFU8-UFT-2.D.FA now that it is discontinued?

Yes. Pepperl Fuchs has discontinued the KFU8-UFT-2.D.FA, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time. If you are planning an upgrade instead, Pepperl Fuchs names the KFU8-UFT-2.D as its successor — we can quote both.

When can KFU8-UFT-2.D.FA be shipped?

KFU8-UFT-2.D.FA is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFU8-UFT-2.D.FA in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFU8-UFT-2.D.FA and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFU8-UFT-2.D.FA, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFU8-UFC-1.D – Frequency Converter with Trip Values
Pepperl Fuchs
KFU8-UFC-1.D

Frequency Converter with Trip Values

Pepperl Fuchs KFU8-UFC-1.D.FA – Frequency Converter with Trip Values
Pepperl Fuchs
KFU8-UFC-1.D.FA

Frequency Converter with Trip Values

Pepperl Fuchs KFU8-UFC-Ex1.D – Frequency Converter with Trip Values
Pepperl Fuchs
KFU8-UFC-Ex1.D

Frequency Converter with Trip Values

Pepperl Fuchs KFU8-UFT-2.D – Frequency Converter with Direction and Synchronization Monitor
Pepperl Fuchs
KFU8-UFT-2.D

Frequency Converter with Direction and Synchronization Monitor

Pepperl Fuchs KFU8-UFT-Ex2.D – Frequency Converter with Direction and Synchronization Monitor
Pepperl Fuchs
KFU8-UFT-Ex2.D

Frequency Converter with Direction and Synchronization Monitor

Pepperl Fuchs KFU8-USC-1.D – Signal Converter with Trip Value
Pepperl Fuchs
KFU8-USC-1.D

Signal Converter with Trip Value

Pepperl Fuchs KHA6-SH-Ex1 – Switch Amplifier
Pepperl Fuchs
KHA6-SH-Ex1

Switch Amplifier

Pepperl Fuchs KFU8-UFT-2.D.FAPrice and lead time confirmed within 1 business day
Request a Quote