What is the Pepperl Fuchs KFU8-UFC-Ex1.D?
1-channel isolated barrier
Universal usage at different power supplies
Input for NAMUR sensors or dry contacts
Input frequency 1 mHz ... 5 kHz
Current output 0/4 mA ... 20 mA
Relay contact and transistor output
Start-up override
Line fault detection (LFD)
Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511
1-channel isolated barrier, Universal usage at different power supplies, Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Start-up override, Frequency conversion, Rotation speed monitoring, Pulse divider
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 231197 |
| Signal type | Digital Input |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
Supply
| Connection | terminals 23, 24 |
| Rated voltage | 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Ur |
| Power dissipation/power consumption | ≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA |
Interface
| Programming interface | programming socket |
Input
| Connection side | field side |
| Connection | Input I: intrinsically safe: terminals 1+, 3- Input II: non-intrinsically safe: terminals 13+, 14- |
| Input I | sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact |
| Pulse duration | > 50 µs |
| Input frequency | 0.001 ... 5000 Hz |
| Line fault detection | breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA |
| Input II | startup override: 1 ... 1000 s, adjustable in steps of 1 s |
| Active/Passive | I > 4 mA (for min. 100 ms) / I < 1.5 mA |
| Open circuit voltage/short-circuit current | 18 V / 5 mA |
Output
| Connection side | control side |
| Connection | output I: terminals 10, 11, 12 output II: terminals 16, 17, 18 outout III: terminasl 19+, 20- output IV: terminals 8+, 7- |
| Output I, II | signal, relay |
| Contact loading | 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A |
| Mechanical life | 5 x 107 switching cycles |
| Energized/De-energized delay | approx. 20 ms / approx. 20 ms |
| Output III | electronic output, passive |
| Contact loading | 40 V DC |
| Signal level | 1-signal: (L+) - 2.5 V (50 mA, short-circuit/overload proof) 0-signal: switched off (off-state current ≤ 10 µA) |
| Output IV | analog |
| Current range | 0 ... 20 mA or 4 ... 20 mA |
| Open loop voltage | max. 24 V DC |
| Load | max. 650 Ω |
| Fault signal | downscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43) |
Transfer characteristics
| Input I: Measuring range | 0.001 ... 5000 Hz |
| Input I: Resolution | 0.1 % of the measurement value , ≥ 0.001 Hz |
| Input I: Accuracy | 0.1 % of the measurement value , > 0.001 Hz |
| Input I: Measuring time | < 100 ms |
| Input I: Influence of ambient temperature | 0.003 %/K (30 ppm) |
| Output I, II: Response delay | ≤ 200 ms |
| Output IV: Resolution | < 10 µA |
| Output IV: Accuracy | < 20 µA |
| Output IV: Influence of ambient temperature | 0.005 %/K (50 ppm) |
Galvanic isolation
| Input I/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output I, II/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Mutual output I, II, III | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output III/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output III/start-up override | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff |
| Output III/IV | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff |
| Output IV/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Start-up override/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Interface/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Interface/output III | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff |
Indicators/settings
| Display elements | LEDs , display |
| Control elements | Control panel |
| Configuration | via operating buttons via PACTware |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Low voltage: Directive 2014/35/EU | EN 61010-1:2010 |
Conformity
| Electromagnetic compatibility | NE 21:2006 |
| Degree of protection | IEC 60529:2001 |
| Input | EN 60947-5-6:2000 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | 300 g |
| Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | TÜV 99 ATEX 1471 |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Supply: Maximum safe voltage | 253 V AC / 125 V DC (Attention! Um is no rated voltage.) Um |
| Input I | terminals 1+, 3-: Ex ia |
| Voltage Uo | 10.1 V |
| Current Io | 13.5 mA |
| Power Po | 34 mW (linear characteristic) |
| Input II | terminals 13+, 14- non-intrinsically safe |
| Maximum safe voltage Um | 40 V (Attention! The rated voltage can be lower.) |
| Output I, II | terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe |
| Maximum safe voltage | 253 V (Attention! The rated voltage can be lower.) Um |
| Contact loading | 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load (TÜV 99 ATEX 1471) |
| Output III | terminals 19+, 20- non-intrinsically safe |
| Maximum safe voltage Um | 40 V (Attention! Um is no rated voltage.) Um |
| Output IV | terminals 8+, 7- non-intrinsically safe |
| Maximum safe voltage | 40 V DC (Attention! Um is no rated voltage.) Um |
| Interface | RS 232 |
| Maximum safe voltage | 40 V (Attention! Um is no rated voltage.) Um |
| Galvanic isolation: Input I/other circuits | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-11:2012 |
International approvals
| FM approval: Control drawing | 16-538FM-12 |
| IECEx approval: IECEx certificate | IECEx TUN 04.0007 |
| IECEx approval: IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (8)
- Taiwan OSHA (ML151200725342)
- EU Declaration of Conformity (Pepperl+Fuchs)
- China SITIIAS CCC Ex Certificate (2020322316001449 (Singapore))
- Australia Test Safe (ANZEx 17.3006X)
- South Africa MASC (MASC MS/17-0881)
- DNV Marine (TAA00001WX)
- United Kingdom CML UK-Type Examination Certificate UKEX Category (1) D UKEX Category (1) G UKEX Category (M1) (CML 22UKEX2510)
- Brasil TUV Rheinland Brazil (TÜV 14.0357)
KFU8-UFC-Ex1.D: frequently asked questions
When can KFU8-UFC-Ex1.D be shipped?
KFU8-UFC-Ex1.D is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFU8-UFC-Ex1.D in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFU8-UFC-Ex1.D and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFU8-UFC-Ex1.D, subject to availability and destination.
More Pepperl Fuchs parts