What is the Pepperl Fuchs KFU8-SR-Ex1.W?

1-channel isolated barrier

Universal usage at different power supplies

Dry contact or NAMUR inputs

Relay contact output

Line fault detection (LFD)

Reversible mode of operation

Up to SIL 2 (SC 3) acc. to IEC/EN 61508

1-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC / 90 ... 253 V AC 50 ... 60 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection

Specifications

General specifications

Order code (Pepperl+Fuchs part number)204137
Signal typeDigital Input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3

Supply

Connectionterminals 14, 15
Rated voltage19 ... 30 V DC / 90 ... 253 V AC 50 ... 60 Hz Ur
Power dissipation/power consumption≤ 1 W / ≤ 1 W ; 3 VA

Input

Connection sidefield side
Connectionterminals 1+, 2+, 3-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I > 6 mA
Pulse/Pause ratiomin. 20 ms / min. 20 ms

Output

Connection sidecontrol side
Connectionterminals 7, 8, 9
Outputsignal ; relay
Contact loading250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 40 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Mechanical life107 switching cycles

Transfer characteristics

Switching frequency< 10 Hz

Galvanic isolation

Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLEDs
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage: Directive 2014/35/EUEN 61010-1:2010+A1:2019+A1:2019/AC:2019

Conformity

Electromagnetic compatibilityNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018 , EN IEC 61326-1:2021 (industrial locations)
Degree of protectionIEC 60529:1989+A1:1999+A2:2013
InputEN 60947-5-6:2000

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Height119 mm
Width20 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateFIDI 22 ATEX 0029 X
MarkingII 3(1)G Ex ec nC [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
InputEx ia
Voltage10.5 V Uo
Current13 mA Io
Power34 mW (linear characteristic) Po
Supply: Maximum safe voltage253 V AC (Attention! Um is no rated voltage.) Um
Output: Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.) Um
Galvanic isolation: Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Galvanic isolation: Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019

International approvals

UL approvalE106378
Control drawing116-0489
Contact loading250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load
IECEx approval: IECEx certificateIECEx FIDI 22.0003X
IECEx approval: IECEx markingEx ec nC [ia Ga] IIC T4 Gc , [Ex ia Da] IIIC , [Ex ia Ma] I

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFU8-SR-Ex1.W: frequently asked questions

When can KFU8-SR-Ex1.W be shipped?

KFU8-SR-Ex1.W is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFU8-SR-Ex1.W in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFU8-SR-Ex1.W and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFU8-SR-Ex1.W, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFU8-GUT-1.D – Temperature Converter with Trip Values
Pepperl Fuchs
KFU8-GUT-1.D

Temperature Converter with Trip Values

Pepperl Fuchs KFU8-GUT-Ex1.D – Temperature Converter with Trip Values
Pepperl Fuchs
KFU8-GUT-Ex1.D

Temperature Converter with Trip Values

Pepperl Fuchs KFU8-SR-1.3L.V – Switch Amplifier, Timer Relay
Pepperl Fuchs
KFU8-SR-1.3L.V

Switch Amplifier, Timer Relay

Pepperl Fuchs KFU8-UFC-1.D – Frequency Converter with Trip Values
Pepperl Fuchs
KFU8-UFC-1.D

Frequency Converter with Trip Values

Pepperl Fuchs KFU8-UFC-1.D.FA – Frequency Converter with Trip Values
Pepperl Fuchs
KFU8-UFC-1.D.FA

Frequency Converter with Trip Values

Pepperl Fuchs KFU8-SR-Ex1.WPrice and lead time confirmed within 1 business day
Request a Quote