1-channel signal conditioner
Universal usage at different power supplies
3-wire PNP/NPN sensor or push-pull input
2 relay contact outputs
Adjustable energized/de-energized delay
Up to SIL 2 (SC 3) acc. to IEC/EN 61508
1-channel signal conditioner, Universal usage at different power supplies, 3-wire PNP/NPN sensor or push-pull input, 2 relay contact outputs, Adjustable energized/de-energized delay, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Time function, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 20 ... 48 V DC or 90 ... 253 V AC , 45 ... 65 Hz, Field device: 3-wire sensor, Field device [2]: Push-pull (4 in 1) output
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 213968 |
| Signal type | Digital Input |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | terminals 14, 15 |
| Rated voltage | 20 ... 48 V DC or 90 ... 253 V AC , 45 ... 65 Hz Ur |
| Rated current | ≤ 230 mA Ir |
| Power dissipation | 2.3 W |
| Power consumption | max. 4.5 W |
Input
| Connection side | field side |
| Connection | terminals 1+, 2, 3- |
| Rated values | 22 ... 24 V DC / 100 mA , see additional information |
| Short-circuit current | max. 125 mA |
| Switching point | PNP: 0-signal: 13.5 V NPN and push-pull output: 0-signal: 5.5 V |
Output
| Connection side | control side |
| Connection | output I: terminals 7, 8, 9 output II: terminals 10, 11, 12 |
| Output I, II | signal, relay |
| Contact loading | 250 V AC / 2 A / cos φ ≥ 0.7 ; 125 V AC/4 A/ cos φ > 0.7 ; 40 V DC / 2 A |
| Mechanical life | 20 x 106 switching cycles |
| Electrical life | 0.2 x 106 switching cycles (40 V DC, 2 A, ohmic) 0.4 x 106 switching cycles (253 V AC, 2 A, cos φ = 1) 0.25 x 106 switching cycles (253 V AC, 2 A, cos φ = 0.7) |
| Minimum load | 50 mW, 5 V DC |
| Energized/De-energized delay | ≤ 90 ms / ≤ 90 ms |
Transfer characteristics
| Switching frequency | ≤ 5 Hz for delay 0 s adjustable energized/de-energized delay: 0 ... 79 s |
Galvanic isolation
| Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Input/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Low voltage: Directive 2014/35/EU | EN 61010-1:2010 |
Conformity
| Electromagnetic compatibility | NE 21:2012 |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 166 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Height | 119 mm |
| Width | 20 mm |
| Depth | 115 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| Supply | 48 V DC |
| Certificate | PF 10 CERT 1417 X |
| Marking | II 3G Ex nA nC IIC T4 Gc |
| Output I, II: Contact loading | 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load |
| Directive conformity: Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
KFU8-SR-1.3L.V: frequently asked questions
When can KFU8-SR-1.3L.V be shipped?
KFU8-SR-1.3L.V is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFU8-SR-1.3L.V in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFU8-SR-1.3L.V and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFU8-SR-1.3L.V, subject to availability and destination.
More Pepperl Fuchs parts