Pepperl Fuchs KFU8-DWB-1.D

Rotation Speed Monitor

MPN
KFU8-DWB-1.D
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs KFU8-DWB-1.D?

1-channel signal conditioner

Universal usage at different power supplies

Dry contact or NAMUR inputs

Input frequency 1 mHz ... 12 kHz

2 relay contact outputs

Start-up override

Configurable by keypad

Line fault detection (LFD)

Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511

1-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Start-up override, Rotation speed monitoring, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz

Specifications

General specifications

Order code (Pepperl+Fuchs part number)231209
Signal typeDigital Input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

Connectionterminals 23, 24
Rated voltage20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz Ur
Rated currentapprox. 100 mA Ir
Power dissipation/power consumption≤ 1.8 W ; 2 VA / 1.8 W ; 2 VA

Input

Connection sidefield side
ConnectionInput I: 2-wire sensor: terminals 1+, 3- three wire sensor: terminals 1+, 2- and 3 input II: terminals 13+, 14- start-up override;
Input I2- or 3-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
Open circuit voltage/short-circuit current22 V / 40 mA
Input resistance4.7 kΩ
Switching point/switching hysteresislogic 1: > 2.5 mA ; logic 0: < 1.9 mA
Pulse duration> 50 µs
Input frequency0.001 ... 12000 Hz
Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 4 mA
Input IIstartup override: 1 ... 1000 s, adjustable in steps of 1 s
Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA
Open circuit voltage/short-circuit current18 V / 5 mA

Output

Connection sidecontrol side
Connectionoutput I: terminals 10, 11, 12 output II: terminals 16, 17, 18
Output I, IIsignal, relay
Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
Mechanical life5 x 107 switching cycles
Energized/De-energized delayapprox. 20 ms / approx. 20 ms

Transfer characteristics

Input I: Measuring range0.001 ... 12000 Hz
Input I: Resolution0.1 % of measured value , ≥ 0.001 Hz
Input I: Accuracy0.1 % of measured value , > 0.001 Hz
Input I: Measuring time< 100 ms
Input I: Influence of ambient temperature0.003 %/K (30 ppm)
Output I, II: Response delay≤ 200 ms

Galvanic isolation

Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachotherreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Start-up override/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLEDs , display
Control elementsControl panel
Configurationvia operating buttons
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage: Directive 2014/35/EUEN 61010-1:2010

Conformity

Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Mass300 g
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Height119 mm
Width40 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFU8-DWB-1.D: frequently asked questions

When can KFU8-DWB-1.D be shipped?

KFU8-DWB-1.D is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFU8-DWB-1.D in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFU8-DWB-1.D and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFU8-DWB-1.D, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFU8-CRG2-1.D – Transmitter Power Supply
Pepperl Fuchs
KFU8-CRG2-1.D

Transmitter Power Supply

Pepperl Fuchs KFU8-DW-1.D – Rotation Speed Monitor
Pepperl Fuchs
KFU8-DW-1.D

Rotation Speed Monitor

Pepperl Fuchs KFU8-FSSP-1.D – Frequency voltage current converter
Pepperl Fuchs
KFU8-FSSP-1.D

Frequency voltage current converter

Pepperl Fuchs KFU8-GUT-1.D – Temperature Converter with Trip Values
Pepperl Fuchs
KFU8-GUT-1.D

Temperature Converter with Trip Values

Pepperl Fuchs KFU8-GUT-Ex1.D – Temperature Converter with Trip Values
Pepperl Fuchs
KFU8-GUT-Ex1.D

Temperature Converter with Trip Values

Pepperl Fuchs KFU8-DWB-1.DPrice and lead time confirmed within 1 business day
Request a Quote