Pepperl Fuchs KFD2-UFC-Ex1.D

Frequency Converter with Trip Values

MPN
KFD2-UFC-Ex1.D
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs KFD2-UFC-Ex1.D?

1-channel isolated barrier

24 V DC supply (Power Rail)

Input for NAMUR sensors or dry contacts

Input frequency 1 mHz ... 5 kHz

Current output 0/4 mA ... 20 mA

Relay contact and transistor output

Start-up override

Line fault detection (LFD)

Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Start-up override, Frequency conversion, Rotation speed monitoring, Pulse divider, Safety Integrity Level (SIL): SIL 2

Specifications

General specifications

Order code (Pepperl+Fuchs part number)231194
Signal typeDigital Input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

Connectionterminals 23+, 24- or power feed module/Power Rail
Rated voltage20 ... 30 V DC Ur
Rated currentapprox. 100 mA Ir
Power dissipation/power consumption≤ 2 W / 2.2 W

Interface

Programming interfaceprogramming socket

Input

Connection sidefield side
ConnectionInput I: intrinsically safe: terminals 1+, 3- Input II: non-intrinsically safe: terminals 13+, 14-
Input Isensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
Pulse duration> 50 µs
Input frequency0.001 ... 5000 Hz
Line fault detectionbreakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input IIstartup override: 1 ... 1000 s, adjustable in steps of 1 s
Active/PassiveI > 4 mA (for min. 100 ms) / I < 1.5 mA
Open circuit voltage/short-circuit current18 V / 5 mA

Output

Connection sidecontrol side
Connectionoutput I: terminals 10, 11, 12 output II: terminals 16, 17, 18 outout III: terminasl 19+, 20- output IV: terminals 8+, 7-
Output I, IIsignal, relay
Contact loading253 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
Mechanical life5 x 107 switching cycles
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Output IIIelectronic output, passive
Contact loading40 V DC
Signal level1-signal: (L+) - 2.5 V (50 mA, short-circuit/overload proof) 0-signal: switched off (off-state current ≤ 10 µA)
Output IVanalog
Current range0 ... 20 mA or 4 ... 20 mA
Open loop voltagemax. 24 V DC
Loadmax. 650 Ω
Fault signaldownscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43)
Collective error messagePower Rail

Transfer characteristics

Input I: Measuring range0.001 ... 5000 Hz
Input I: Resolution0.1 % of the measurement value , ≥ 0.001 Hz
Input I: Accuracy0.1 % of the measurement value , > 0.001 Hz
Input I: Measuring time< 100 ms
Input I: Influence of ambient temperature0.003 %/K (30 ppm)
Output I, II: Response delay≤ 200 ms
Output IV: Resolution< 10 µA
Output IV: Accuracy< 20 µA
Output IV: Influence of ambient temperature0.005 %/K (50 ppm)

Galvanic isolation

Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, IIIreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/power supply and collective errorbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III/start-up overridebasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III/IVbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output IV/power supply and collective errorfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Start-up override/power supply and collective errorfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Interface/power supply and collective errorfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Interface/output IIIbasic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Indicators/settings

Display elementsLEDs , display
Control elementsControl panel
Configurationvia operating buttons via PACTware
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage: Directive 2014/35/EUEN 61010-1:2010

Conformity

Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
InputEN 60947-5-6:2000

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Mass300 g
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Height119 mm
Width40 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateTÜV 99 ATEX 1471
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Supply: Maximum safe voltage40 V DC (Attention! Um is no rated voltage.) Um
Input Iterminals 1+, 3-: Ex ia
Voltage Uo10.1 V
Current Io13.5 mA
Power Po34 mW (linear characteristic)
Input IIterminals 13+, 14- non-intrinsically safe
Maximum safe voltage Um40 V (Attention! The rated voltage can be lower.)
Output I, IIterminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
Maximum safe voltage253 V (Attention! The rated voltage can be lower.) Um
Contact loading253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
Output IIIterminals 19+, 20- non-intrinsically safe
Maximum safe voltage Um40 V (Attention! Um is no rated voltage.) Um
Output IVterminals 8+, 7- non-intrinsically safe
Maximum safe voltage40 V DC (Attention! Um is no rated voltage.) Um
InterfaceRS 232
Maximum safe voltage40 V (Attention! Um is no rated voltage.) Um
CertificateTÜV 02 ATEX 1885 X
MarkingII 3G Ex nA nC IIC T4 Gc
Output I, II: Contact loading50 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load
Galvanic isolation: Input I/other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010

International approvals

FM approval: Control drawing16-538FM-12
UL approvalE223772
IECEx approval: IECEx certificateIECEx TUN 04.0007 IECEx TSA 18.0007X
IECEx approval: IECEx marking[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex ec nC IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFD2-UFC-Ex1.D: frequently asked questions

When can KFD2-UFC-Ex1.D be shipped?

KFD2-UFC-Ex1.D is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFD2-UFC-Ex1.D in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFD2-UFC-Ex1.D and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-UFC-Ex1.D, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFD2-STC5-Ex2 – SMART Transmitter Power Supply
Pepperl Fuchs
KFD2-STC5-Ex2

SMART Transmitter Power Supply

Pepperl Fuchs KFD2-UFC-1.D – Frequency Converter with Trip Values
Pepperl Fuchs
KFD2-UFC-1.D

Frequency Converter with Trip Values

Pepperl Fuchs KFD2-UFT-2.D – Frequency Converter with Direction and Synchronization Monitor
Pepperl Fuchs
KFD2-UFT-2.D

Frequency Converter with Direction and Synchronization Monitor

Pepperl Fuchs KFD2-UFT-Ex2.D – Frequency Converter with Direction and Synchronization Monitor
Pepperl Fuchs
KFD2-UFT-Ex2.D

Frequency Converter with Direction and Synchronization Monitor

Pepperl Fuchs KFD2-USC-1.D – Signal Converter with Trip Value
Pepperl Fuchs
KFD2-USC-1.D

Signal Converter with Trip Value

Pepperl Fuchs KFD2-UT2-1 – Universal Temperature Converter
Pepperl Fuchs
KFD2-UT2-1

Universal Temperature Converter

Pepperl Fuchs KFD2-UFC-Ex1.DPrice and lead time confirmed within 1 business day