Pepperl Fuchs KFD2-SR2-Ex1.W

Switch Amplifier

MPN
KFD2-SR2-Ex1.W
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs KFD2-SR2-Ex1.W?

1-channel isolated barrier

24 V DC supply (Power Rail)

Dry contact or NAMUR inputs

Relay contact output

Line fault detection (LFD)

Reversible mode of operation

Up to SIL 2 (SC 3) acc. to IEC/EN 61508

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact)

Specifications

General specifications

Order code (Pepperl+Fuchs part number)70101737
Signal typeDigital Input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3

Supply

ConnectionPower Rail or terminals 14+, 15-
Rated voltage19 ... 30 V DC Ur
Ripple≤ 10 %
Rated current≤ 35 mA Ir
Power dissipation≤ 0.7 W
Power consumption≤ 0.7 W

Input

Connection sidefield side
Connectionterminals 1+, 2+, 3-
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Line fault detectionbreakage I ≤ 0.1 mA , short-circuit I > 6 mA
Pulse/Pause ratiomin. 20 ms / min. 20 ms

Output

Connection sidecontrol side
Connectionterminals 7, 8, 9
Outputsignal ; relay
Contact loading250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 40 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Mechanical life107 switching cycles
Collective error messagePower Rail

Transfer characteristics

Switching frequency< 10 Hz

Galvanic isolation

Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLEDs
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage: Directive 2014/35/EUEN 61010-1:2010+A1:2019+A1:2019/AC:2019

Conformity

Electromagnetic compatibilityNE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018
Degree of protectionIEC 60529:1989+A1:1999+A2:2013
Functional safetyIEC/EN 61508:2010
InputEN 60947-5-6:2000

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificatePTB 00 ATEX 2080
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
InputEx ia
Voltage10.5 V Uo
Current13 mA Io
Power34 mW (linear characteristic) Po
Supply: Maximum safe voltage253 V AC / 125 V DC (Attention! Um is no rated voltage.) Um
Output: Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.) Um
Fault indication output: Maximum safe voltage40 V DC (Attention! Um is no rated voltage.) Um
CertificatePF 08 CERT 0803
MarkingII (3)G [Ex ic Gc] IIC
InputEx ic
Voltage10.5 V Uo
Current13 mA Io
Power34 mW (linear characteristic) Po
CertificateTÜV 99 ATEX 1493 X
MarkingII 3G Ex ec nC IIC T4 Gc
Galvanic isolation: Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Galvanic isolation: Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN IEC 60079-11:2024 , EN IEC 60079-15:2019

International approvals

FM approval: FM certificateFM19US0207X
FM approval: Control drawing116-0035
UL approvalE106378
Control drawing116-0473 (cULus)
Contact loading250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load
IECEx approval: IECEx certificateIECEx PTB 11.0034 , IECEx TUN 19.0013X
IECEx approval: IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I Ex ec nC IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFD2-SR2-Ex1.W: frequently asked questions

When can KFD2-SR2-Ex1.W be shipped?

KFD2-SR2-Ex1.W is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFD2-SR2-Ex1.W in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFD2-SR2-Ex1.W and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-SR2-Ex1.W, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFD2-SR2-2.W.SM – Standstill and Rotational Direction Monitor
Pepperl Fuchs
KFD2-SR2-2.W.SM

Standstill and Rotational Direction Monitor

Pepperl Fuchs KFD2-SR2-Ex2.W.SM – Standstill and Rotational Direction Monitor
Pepperl Fuchs
KFD2-SR2-Ex2.W.SM

Standstill and Rotational Direction Monitor

Pepperl Fuchs KFD2-SR2-Ex1.WPrice and lead time confirmed within 1 business day
Request a Quote