What is the Pepperl Fuchs KFD2-RSH-1.2E.L3?
1-channel signal conditioner
24 V DC supply
Logic input 19 V DC ... 26.4 V DC
Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC
Relay contact output for energized to safe function
Line fault transparency (LFT)
Diagnostic function
Up to SIL 3 acc. to IEC/EN 61508
1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... 110 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, ETS function (energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 274896 |
| Signal type | Digital Output |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | Power Rail or terminals 14+, 15- |
| Rated voltage | 19 ... 26.4 V DC Ur |
| Input current | max. 35 mA at 24 V DC , max. 44 mA at 19 V DC , with enabled internal fault detection |
| Power consumption | < 1.7 W , includes the power consumption of the digital input , see derating curves |
Input
| Connection side | control side |
| Connection | terminals 7+, 8- |
| Pulse/Pause ratio | min. 150 ms / min. 150 ms with disabled internal fault detection min. 1 s / min. 1 s with enabled internal fault detection |
| Test pulse length | max. 2 ms from DO card |
| Signal level | 0-signal: -5 ... 5 V DC 1-signal: 19 ... 26.4 V DC |
| Rated current | 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card) Ir |
| Inrush current | < 200 mA after 100 µs |
Output
| Connection side | field side |
| Connection | external voltage : terminals 5+/L, 2-/N load : terminals 6, 3 |
| Connectable voltage | 50 ... 230 V AC 60 ... 110 V DC |
| Power dissipation | < 3.3 W at 5 A , see derating curves |
| Contact loading | 253 V AC/5 A/cos φ 0.7; 30 V DC/5 A resistive load , see derating curves |
| Minimum switch current | 10 mA |
| Mechanical life | 5 x 106 switching cycles |
| Line fault detection | low voltage undercurrent: 10 mA AC; overcurrent: 5.5 A AC (relay energized) breakage: 48 kΩ; short-circuit: 29 Ω (load, relay de-energized) |
Fault indication output
| Connection | terminals 10, 11 |
| Contact loading | 30 V DC/ 0.5 A resistive load |
| Reaction time | < 2 s |
| Mechanical life | 105 switching cycles |
Transfer characteristics
| Switching frequency | < 0.5 Hz with enabled internal fault detection |
Galvanic isolation
| Input/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff |
| Input/fault indication output | basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 Veff |
| Output/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Low voltage: Directive 2014/35/EU | EN 61010-1:2010 |
Conformity
| Electromagnetic compatibility | NE 21:2017 , IEC/EN 61326-3-2:2018 , EN 61326-3-1:2017 |
| Degree of protection | IEC 60529:2013 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) Observe the temperature range limited by derating, see section derating. |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 134 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
KFD2-RSH-1.2E.L3: frequently asked questions
When can KFD2-RSH-1.2E.L3 be shipped?
KFD2-RSH-1.2E.L3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-RSH-1.2E.L3 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-RSH-1.2E.L3 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-RSH-1.2E.L3, subject to availability and destination.
More Pepperl Fuchs parts