What is the Pepperl Fuchs KFD0-TT-Ex1?

1-channel isolated barrier

24 V DC supply (loop powered)

Thermocouple input

Output 4 mA ... 20 mA

Internal cold junction compensation

Sensor breakage detection

DIP switch selectable ranges

1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor breakage detection, DIP switch selectable ranges, Housing width: 20 mm, Number of channels: 1-channel, Internal cold junction compensation, Rated voltage: 12 ... 35 V DC loop powered, Type: 2-wire connection, Field device: Thermocouple, Line fault detection, Signal: 1 x 4 ... 20 mA (current sink)

Specifications

General specifications

Order code (Pepperl+Fuchs part number)043692
Signal typeAnalog input
LifecycleActive (current Pepperl+Fuchs product)

Supply

Rated voltage12 ... 35 V DC loop powered Ur
Power dissipation0.4 W

Input

Connection sidefield side
Connectionterminals 1+, 2-, 3- thermocouple E, J, K, N, R, S or T, cold junction referenced to 0 °C (32 °F)
Lead resistancemax. 100 Ω per line
Currentlead monitoring ON: ≤ 15 nA; OFF: ≤ 1 nA

Output

Connection sidecontrol side
Connectionterminals 9+, 8-
Load(U -12 V) / 0.02 A
Current output4 ... 20 mA , limited to ≤ 35 mA
Fault signaldownscaling ≤ 3 mA , upscaling ≥ 22 mA

Transfer characteristics

Measuring rangespan 4 ... 100 mV, zero point -12 ... 60 mV , both adjustable fn
Deviation: After calibration0.1 % of full-scale value ± 1 K for the cold junction
Deviation: Temperature effecttemperature deviation 0.015 % of the span/K or 1.5 µV/K cold junction ± 2 K (calibrated at Tamb = 20 °C (68 °F))
Deviation: Influence of supply voltage6.5 ppm/V
Characteristic curvethe output voltage is linearly proportionate to the input voltage (not to temperature)
Rise time250 ms

Galvanic isolation

Input/Outputsafe isolation according to EN 50178, rated insulation voltage 253 Veff

Indicators/settings

Control elementsDIP switch rotary switch
Configurationvia DIP switches via rotary switch
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Insulation coordinationEN 50178
Galvanic isolationEN 50178
Degree of protectionIEC 60529

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Height119 mm
Width20 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateZELM 00 ATEX 0035
MarkingII (1)GD [EEx ia] IIC
Voltage16.1 V Uo
Current0.8 mA Io
Power3.2 mW Po
Output: Maximum safe voltage60 V (Attention! The rated voltage can be lower.) Um
CertificateTÜV 01 ATEX 1777 X
MarkingII 3G Ex nA II T4
Galvanic isolation: Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010

International approvals

CSA approval: Control drawing116-0132

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFD0-TT-Ex1: frequently asked questions

When can KFD0-TT-Ex1 be shipped?

KFD0-TT-Ex1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFD0-TT-Ex1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFD0-TT-Ex1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD0-TT-Ex1, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFD0-TR-1 – RTD Converter
Pepperl Fuchs
KFD0-TR-1

RTD Converter

Pepperl Fuchs KFD2-CRG2-1.D – Transmitter Power Supply
Pepperl Fuchs
KFD2-CRG2-1.D

Transmitter Power Supply

Pepperl Fuchs KFD0-TT-Ex1Price and lead time confirmed within 1 business day
Request a Quote