Pepperl Fuchs KFD0-TR-Ex1
RTD Converter
- MPN
- KFD0-TR-Ex1
- Category
- K-System (DIN Rail Mounting)
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs KFD0-TR-Ex1?
1-channel isolated barrier
24 V DC supply (loop powered)
2- or 3-wire Pt100 RTD input
Output 4 mA ... 20 mA, temperature linearization selectable
DIP switch selectable ranges
Sensor breakage detection
1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectable, DIP switch selectable ranges, Sensor breakage detection, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 12 ... 35 V DC loop powered, Type: 3-wire connection, Field device: resistance thermometer, Signal: 1 x 4 ... 20 mA (current sink)
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 043691 |
| Signal type | Analog input |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Supply
| Rated voltage | 12 ... 35 V DC loop powered Ur |
| Power dissipation | 0.4 W |
Input
| Connection side | field side |
| Connection | terminals 1, 2-, 3+ suitable for Pt100, 2- and 3-wire connection |
| Lead resistance | max. 100 Ω per line |
| Measuring current | approx. 1 mA |
Output
| Connection side | control side |
| Connection | terminals 9+, 8- |
| Load | (U -12 V) / 0.02 A |
| Current output | 4 ... 20 mA , limited to ≤ 35 mA |
| Fault signal | upscaling ≥ 22 mA (limited to 35 mA) |
Transfer characteristics
| Measuring range | span without linearization 25 ... 800 °C (77 ... 1472 °F)/with linearization 25 ... 375 °C (77 ... 707 °F), both adjustable zero point without linearization -200 ... 400 °C (-328 ... 752 °F)/with linearization -30 ... 375 °C (-22 ... 707 °F), both adjustable fn |
| Deviation: After calibration | 0.1 % of full-scale value incl. linearity and hysteresis |
| Deviation: Influence of ambient temperature | span and zero point 0.015 % / K or ± 10 mΩ / K |
| Deviation: Influence of supply voltage | 6.5 ppm/V |
| Rise time | 250 ms |
Galvanic isolation
| Input/Output | available |
Indicators/settings
| Control elements | DIP switch rotary switch |
| Configuration | via DIP switches via rotary switch |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Insulation coordination | EN 50178 |
| Galvanic isolation | EN 50178 |
| Degree of protection | IEC 60529 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 150 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Height | 119 mm |
| Width | 20 mm |
| Depth | 115 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | ZELM 00 ATEX 0036 |
| Marking | II (1)GD [EEx ia] IIC |
| Voltage | 16.1 V Uo |
| Current | 33 mA Io |
| Power | 131 mW Po |
| Certificate | TÜV 01 ATEX 1777 X |
| Marking | II 3G Ex nA II T4 |
| Galvanic isolation: Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals
| CSA approval | 1029981 |
| Control drawing | 116-0132 |
| IECEx approval: IECEx certificate | IECEx TUN 06.0004 |
| IECEx approval: IECEx marking | [Zone 0] [Ex ia] IIC |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (8)
- China SITIIAS CCC Ex Certificate (2021322316004118 (Singapore))
- EU Declaration of Conformity (Pepperl+Fuchs)
- South Africa MASC (MASC S/18-2610)
- South Africa MASC Zone 2 (MASC S/17-0871X)
- Canada CSA (CoC 1029981 C)
- Ukraine SERTIS Ex (SC 21.0646 X)
- Europe TUV Nord ATEX Category 3 (TÜV 01 ATEX 1777X)
- Europe ZELM ATEX Category (1) GD (ZELM 00 ATEX 0036)
KFD0-TR-Ex1: frequently asked questions
When can KFD0-TR-Ex1 be shipped?
KFD0-TR-Ex1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD0-TR-Ex1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD0-TR-Ex1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD0-TR-Ex1, subject to availability and destination.
More Pepperl Fuchs parts