What is the Pepperl Fuchs KFD0-CS-Ex2.52?

2-channel isolated barrier

24 V DC supply (loop powered)

Current input/output 4 mA ... 20 mA

Accuracy 0.1 %

Entity parameter Io/Isc = 0 mA

2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, Accuracy 0.1 %, Entity parameter Io/Isc = 0 mA, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the control system, Rated voltage: 4 ... 24 V DC , loop powered, Signal: 2 x 4 ... 20 mA, Signal: 2 x 4 ... 20 mA

Specifications

General specifications

Order code (Pepperl+Fuchs part number)183893
Signal typeAnalog input
LifecycleActive (current Pepperl+Fuchs product)

Supply

Rated voltage4 ... 24 V DC , loop powered Ur
Power dissipation150 mW
Power consumption1 W

Control circuit

Connectionterminals 12-, 11+; 8-, 10-, 9+
Voltage4 ... 24 V DC for 4 V < Uin < 24 V: 0.97 x Uin - (85 x current in A) - 1.3
Current4 ... 20 mA

Field circuit

Connectionterminals 1+, 2-; 4+, 5-
Transmission rangecurrent: 4 ... 24 mA voltage: 4 ... 24 V DC

Transfer characteristics

Accuracy0.1 %
Deviation: After calibration± 20 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), Uin ≤ 20 V +20 µA/-50 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), 20 V < Uin < 24 V
Deviation: Influence of ambient temperature± 1 µA/K (0 ... 50 °C (32 ... 122 °F)), Uin ≤ 12 V ± 2 µA/K (0 ... 60 °C (32 ... 140 °F)), Uin ≤ 18 V ± 5 µA/K (-20 ... 60 °C (-4 ... 140 °F)), Uin ≤ 24 V
Rise time≤ 10 ms at 4 ... 20 mA and 250 Ω load

Galvanic isolation

Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V

Indicators/settings

Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1:2012

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Height119 mm
Width20 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateBASEEFA 03 ATEX 0141
MarkingII (1)GD, I (M1) [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20 °C ≤ Tamb ≤ 60 °C) , [circuit(s) in zone 0/1/2]
Voltage25.2 V DC Uo
Current0 mA Io
Output: Maximum safe voltage253 V eff (Attention! The rated voltage can be lower.) Um
CertificateTÜV 99 ATEX 1499 X
MarkingII 3G Ex nA II T4 [device in zone 2]
Galvanic isolation: Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010

International approvals

FM approval: Control drawing116-0129
UL approval: Control drawing116-0173 (cULus)
IECEx approval: IECEx certificateIECEx BAS 08.0059
IECEx approval: IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFD0-CS-Ex2.52: frequently asked questions

When can KFD0-CS-Ex2.52 be shipped?

KFD0-CS-Ex2.52 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFD0-CS-Ex2.52 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFD0-CS-Ex2.52 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD0-CS-Ex2.52, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFD0-HMS-16 – HART MUX Secondary Module
Pepperl Fuchs
KFD0-HMS-16

HART MUX Secondary Module

Pepperl Fuchs KFD0-LGH – Place Holder Barrier
Pepperl Fuchs
KFD0-LGH

Place Holder Barrier

Pepperl Fuchs KFD0-LGH-5T – Place Holder Barrier
Pepperl Fuchs
KFD0-LGH-5T

Place Holder Barrier

Pepperl Fuchs KFD0-CS-Ex2.52Price and lead time confirmed within 1 business day
Request a Quote