Pepperl Fuchs KFD0-CS-Ex2.52
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | K-System (DIN Rail Mounting) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can KFD0-CS-Ex2.52 be shipped?
KFD0-CS-Ex2.52 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD0-CS-Ex2.52 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD0-CS-Ex2.52 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD0-CS-Ex2.52, subject to availability and destination.
Repeater. 2-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, Accuracy 0.1 %, Entity parameter I<sub>o</sub>/I<sub>sc</sub> = 0 mA, Housing width: 20 mm, Number of channels: 2-channel, Transfer direction: to the control system, Rated voltage: 4 ... 24 V DC , loop powered, Signal: 2 x 4 ... 20 mA, Signal: 2 x 4 ... 20 mA. Signal type: Analog input. Rated voltage: 4 ... 24 V DC , loop powered. Power dissipation: 150 mW. Power consumption: 1 W. Connection: terminals 12-, 11+; 8-, 10-, 9+. Voltage: 4 ... 24 V DC for 4 V < Uin < 24 V: 0.97 x Uin - (85 x current in A) - 1.3. Current: 4 ... 20 mA. Connection: terminals 1+, 2-; 4+, 5-. Transmission range: current: 4 ... 24 mA voltage: 4 ... 24 V DC. Accuracy: 0.1 %. Deviation: . After calibration± 20 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), Uin ≤ 20 V +20 µA/-50 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), 20 V < Uin < 24 VInfluence of ambient temperature± 1 µA/K (0 ... 50 °C (32 ... 122 °F)), Uin ≤ 12 V ± 2 µA/K (0 ... 60 °C (32 ... 140 °F)), Uin ≤ 18 V ± 5 µA/K (-20 ... 60 °C (-4 ... 140 °F)), Uin ≤ 24 V: . After calibration: ± 20 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), Uin ≤ 20 V +20 µA/-50 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), 20 V < Uin < 24 V. Influence of ambient temperature: ± 1 µA/K (0 ... 50 °C (32 ... 122 °F)), Uin ≤ 12 V ± 2 µA/K (0 ... 60 °C (32 ... 140 °F)), Uin ≤ 18 V ± 5 µA/K (-20 ... 60 °C (-4 ... 140 °F)), Uin ≤ 24 V. Rise time: ≤ 10 ms at 4 ... 20 mA and 250 Ω load. Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529:2001. Protection against electrical shock: UL 61010-1:2012. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Connection: screw terminals. Mass: approx. 100 g. Dimensions: 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2. Height119 mmWidth20 mmDepth115 mm: . Height: 119 mm. Width: 20 mm. Depth: 115 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: BASEEFA 03 ATEX 0141. Marking II (1)GD, I (M1) [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20 °C ≤ Tamb ≤ 60 °C) , [circuit(s) in zone 0/1/2]VoltageUo25.2 V DCCurrentIo0 mA: . Marking: II (1)GD, I (M1) [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20 °C ≤ Tamb ≤ 60 °C) , [circuit(s) in zone 0/1/2]. Voltage: 25.2 V DC. Current: 0 mA. Output: . Maximum safe voltageUm253 V eff (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 253 V eff (Attention! The rated voltage can be lower.). Certificate: TÜV 99 ATEX 1499 X. Marking II 3G Ex nA II T4 [device in zone 2]: . Marking: II 3G Ex nA II T4 [device in zone 2]. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. FM approval: . Control drawing116-0129: . Control drawing: 116-0129. UL approval: . Control drawing116-0173 (cULus): . Control drawing: 116-0173 (cULus). IECEx approval: . IECEx certificateIECEx BAS 08.0059IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I: . IECEx certificate: IECEx BAS 08.0059. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Signal type | Analog input |
Supply
| Rated voltage | 4 ... 24 V DC , loop powered Ur |
| Power dissipation | 150 mW |
| Power consumption | 1 W |
Control circuit
| Connection | terminals 12-, 11+; 8-, 10-, 9+ |
| Voltage | 4 ... 24 V DC for 4 V < Uin < 24 V: 0.97 x Uin - (85 x current in A) - 1.3 |
| Current | 4 ... 20 mA |
Field circuit
| Connection | terminals 1+, 2-; 4+, 5- |
| Transmission range | current: 4 ... 24 mA voltage: 4 ... 24 V DC |
Transfer characteristics
| Accuracy | 0.1 % |
| Deviation | |
| After calibration± 20 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), Uin ≤ 20 V +20 µA/-50 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), 20 V < Uin < 24 VInfluence of ambient temperature± 1 µA/K (0 ... 50 °C (32 ... 122 °F)), Uin ≤ 12 V ± 2 µA/K (0 ... 60 °C (32 ... 140 °F)), Uin ≤ 18 V ± 5 µA/K (-20 ... 60 °C (-4 ... 140 °F)), Uin ≤ 24 V | After calibration |
| After calibration | ± 20 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), Uin ≤ 20 V +20 µA/-50 µA incl. calibration, linearity, hysteresis and load fluctuations at 20 °C (68 °F), 20 V < Uin < 24 V |
| Influence of ambient temperature | ± 1 µA/K (0 ... 50 °C (32 ... 122 °F)), Uin ≤ 12 V ± 2 µA/K (0 ... 60 °C (32 ... 140 °F)), Uin ≤ 18 V ± 5 µA/K (-20 ... 60 °C (-4 ... 140 °F)), Uin ≤ 24 V |
| Rise time | ≤ 10 ms at 4 ... 20 mA and 250 Ω load |
Galvanic isolation
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
Indicators/settings
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 (industrial locations) | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2011 |
| Degree of protection | IEC 60529:2001 |
| Protection against electrical shock | UL 61010-1:2012 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 100 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Height119 mmWidth20 mmDepth115 mm | Height |
| Height | 119 mm |
| Width | 20 mm |
| Depth | 115 mm |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | BASEEFA 03 ATEX 0141 |
| Marking II (1)GD, I (M1) [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20 °C ≤ Tamb ≤ 60 °C) , [circuit(s) in zone 0/1/2]VoltageUo25.2 V DCCurrentIo0 mA | Marking |
| Marking | II (1)GD, I (M1) [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I (-20 °C ≤ Tamb ≤ 60 °C) , [circuit(s) in zone 0/1/2] |
| Voltage | 25.2 V DC Uo |
| Current | 0 mA Io |
| Output | |
| Maximum safe voltageUm253 V eff (Attention! The rated voltage can be lower.) | Um Maximum safe voltage |
| Maximum safe voltage | 253 V eff (Attention! The rated voltage can be lower.) Um |
| Certificate | TÜV 99 ATEX 1499 X |
| Marking II 3G Ex nA II T4 [device in zone 2] | Marking |
| Marking | II 3G Ex nA II T4 [device in zone 2] |
| Galvanic isolation | |
| Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V | Input/Output |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals
| FM approval | |
| Control drawing116-0129 | Control drawing |
| Control drawing | 116-0129 |
| UL approval | |
| Control drawing116-0173 (cULus) | Control drawing |
| Control drawing | 116-0173 (cULus) |
| IECEx approval | |
| IECEx certificateIECEx BAS 08.0059IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I | IECEx certificate |
| IECEx certificate | IECEx BAS 08.0059 |
| IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G