What is the Pepperl Fuchs HiC2877?
1-channel isolated barrier
24 V DC supply (bus or loop powered)
Output 40 mA at 11.2 V DC, 55 mA current limit
Contact or logic control input
Entity parameter Io/Isc = 93 mA
Line fault detection (LFD)
Test pulse immunity
Up to SIL 3 acc. to IEC/EN 61508 (loop powered)
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 40 mA at 11.2 V DC, 55 mA current limit, Contact or logic control input, Entity parameter Io/Isc = 93 mA, Line fault detection (LFD), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508 (loop powered), Housing width: 12.5 mm, Number of channels: 1-channel, Filter, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 278769 |
| Signal type | Digital Output |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | SL1: 1a, 1b(-); 2a, 2b(+) |
| Rated voltage | 20.4 ... 30 V DC loop powered 20.4 ... 30 V DC bus powered via Termination Board Ur |
| Input current | 62 mA at 24 V, 300 Ω load |
| Power dissipation | 1 W at 24 V, 300 Ω load |
Input
| Connection side | control side |
| Connection | SL1: 8a(+), 7a(-) loop powered SL1: 10a(+), 9a(-) bus powered |
| Control input | external switch (dry contact or open collector) non isolated or logic signal input fully floating |
| Signal level | 1-signal: 15...30 V DC (current limited to 3 mA) or contact close (internal 10 kΩ pull-up) 0-signal: 0...5 V DC or contact open |
| Power dissipation | 1 W at 24 V, 300 Ω load for loop powered |
| Inrush current | 0.2 A , 15 ms loop powered |
Output
| Connection side | field side |
| Connection | SL2: 5a(+), 5b(-) |
| Internal resistor | approx. 280 Ω Ri |
| Current | ≤ 40 mA Ie |
| Voltage | ≥ 11.2 V Ue |
| Current limit | 55 mA Imax |
| Open loop voltage | approx. 22.5 V Us |
| Load | nominal 0.1 ... 5 kΩ |
| Switching frequency | - bus powered: filter OFF: max. 150 Hz, filter ON: max. 15 Hz - loop powered: max. 10 Hz f |
| Energized/De-energized delay | - bus powered: filter OFF: 1 ms, filter ON: 10 ms - loop powered: switch-on 50 ms, switch-off 6 ms (300 Ω load) |
| Line fault detection: Short-circuit | < 25 Ω |
| Line fault detection: Open-circuit | > 100 kΩ |
| Line fault detection: Test current | < 4 mA |
Fault indication output
| Connection | SL1: 6b |
| Output type | open collector transistor (internal fault bus) |
| Fault current | 4 mA pulsing (20 ms ON, 200 ms OFF) |
| Fault level | lead short-circuit detection at 100 kΩ typical |
Galvanic isolation
| Output/power supply, inputs, and collective error | safe electrical isolation acc. to EN 60079-11: 2007, voltage peak value 375 V |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Factory setting | bus powered, input: dry contact, line fault detection enabled |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2006 For further information see system description. |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Mass | approx. 100 g |
| Dimensions | 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D) |
| Height | 106 mm |
| Width | 12.5 mm |
| Depth | 128 mm |
| Mounting | on termination board |
| Coding | pin 2 and 3 trimmed For further information see system description. |
Data for application in connection with hazardous areas
| EU-type examination certificate | CESI 10 ATEX 046 |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Output | Ex ia Ga, Ex ia Da, Ex ia Ma |
| Voltage | 25.2 V Uo |
| Current | 93 mA Io |
| Power | 586 mW Po |
| Supply: Maximum safe voltage | 253 V AC (Attention! Um is no rated voltage.) Um |
| Certificate | KIWA 15 ATEX 0036 X |
| Marking | II 3G Ex ec IIC T4 Gc |
| Directive conformity: Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-7:2015+A1:2018 |
International approvals
| FM approval: Control drawing | 116-0431 (cFMus) |
| UL approval: Control drawing | 116-0383 (cULus) |
| IECEx approval: IECEx certificate | IECEx CES 10.0017 IECEx KIWA 15.0018X |
| IECEx approval: IECEx marking | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex ec IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (11)
- United Arab Emirates SGS Gulf Limited ECASEx (26-01-177835/E26-01-185194/NB0002 (Vietnam))
- United Arab Emirates SGS Gulf Limited ECASEx (26-01-177827/E26-01-185193/NB0002 (Vietnam))
- EU Declaration of Conformity (Pepperl+Fuchs)
- Brasil TUV Rheinland Brazil (TÜV 18.3033)
- Europe KIWA ATEX Category 3 G (KIWA 15 ATEX 0036X)
- Europe CESI ATEX Category (1) D ATEX Category (1) G ATEX Category (M1) (CESI 10 ATEX 046)
- Canada USA UL Certificate of Compliance Hazardous Location UL E106378 cULus (CoC 20181016 - E106378 RepRef 20140228)
- Canada FM (FM 17 CA 0057X)
- USA FM (FM 17 US 0111X)
- exida Functional Safety Assessment (P+F 11/07-044 R034 V1R2)
- Korea KOSHA (15-AV4BO-0597)
HiC2877: frequently asked questions
When can HiC2877 be shipped?
HiC2877 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up HiC2877 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for HiC2877 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HiC2877, subject to availability and destination.