Quick facts

AvailabilityConfirmed on request
CategoryH-System (Termination Board Mounting)
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can HiC2031HC be shipped?

HiC2031HC is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up HiC2031HC in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for HiC2031HC and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HiC2031HC, subject to availability and destination.

SMART Current Driver. 1-channel isolated barrier, 24 V DC supply (bus powered), Current output up to 625 Ω load, HART-IP and valve positioner, Low power dissipation, Suitable for long field cables (> 1000 m), Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Transfer direction: to the field, HART communication, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Signal: 1 x 4 ... 20 mA. Signal type: Analog output. Safety Integrity Level (SIL): SIL 2. Systematic capability (SC): SC 3. Connection: SL1: 1a(-), 1b(-); 2a(+), 2b(+). Rated voltage: 19 ... 30 V DC bus powered via Termination Board. Ripple: ≤ 10 %. Rated current: ≤ 35 mA. Power dissipation: ≤ 600 mW. Power consumption: ≤ 700 mW. Connection side: control side. Connection: SL1: 8a(+), 7a(-). Input signal: 4 ... 20 mA , limited to approx. 27 mA. Input voltage: depending on switch configurationopen loop voltage of the control system < 19 Vopen loop voltage of the control system < 26 V. Voltage drop: depending on switch configurationopen loop voltage of the control system < 19 V: approx. 5 V at 20 mAopen loop voltage of the control system < 26 V: approx. 12 V at 20 mA. Input resistance: > 100 kΩ, with field wiring open. Connection side: field side. Connection: SL2: 5a(+), 5b(-). Voltage: ≥ 12.5 V at 20 mA. Current: 4 ... 20 mA. Load: 0 ... 625 Ω. Ripple: 20 mV rms. Deviation: at 20 °C (68 °F), 4 ... 20 mA ≤ ± 0.1 % incl. non-linearity and hysteresis. Influence of ambient temperature< 2 µA/K (0 ... 60 °C (32 ... 140 °F)); < 4 µA/K (-20 ... 0 °C (-4 ... 32 °F)): . Influence of ambient temperature: < 2 µA/K (0 ... 60 °C (32 ... 140 °F)); < 4 µA/K (-20 ... 0 °C (-4 ... 32 °F)). Frequency range: field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 1 mApp signal 0 ... 3 kHz (-3 dB). Rise time: 10 to 90 % ≤ 100 ms. Display elements: LED. Control elements: DIP switch. Factory setting: input: max. input voltage 19 V. Configuration: via DIP switches. Labeling: space for labeling at the front. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2012For further information see system description.. Degree of protection: IEC 60529. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Degree of protection: IP20. Mass: approx. 100 g. Dimensions: 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D). Height106 mmWidth12.5 mmDepth128 mm: . Height: 106 mm. Width: 12.5 mm. Depth: 128 mm. Mounting: on termination board. Coding: pin 2 and 4 trimmed For further information see system description.. EU-type examination certificate: CESI 11 ATEX 012. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutputEx ia: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Output: Ex ia. Supply: . Maximum safe voltageUm253 V AC (Attention! Um is no rated voltage.): Um. Maximum safe voltage: 253 V AC (Attention! Um is no rated voltage.). Equipment: SL2: 5a(+), 5b(-). VoltageUo20 VCurrentIo100 mAPowerPo500 mWInternal capacitanceCi5.7 nFInternal inductanceLinegligible: Uo. Voltage: 20 V. Current: 100 mA. Power: 500 mW. Internal capacitance: 5.7 nF. Internal inductance: negligible. Output: . Maximum safe voltageUm253 V AC (Attention! The rated voltage can be lower.): Um. Maximum safe voltage: 253 V AC (Attention! The rated voltage can be lower.). Certificate: CESI 19 ATEX 050 X. Marking II 3G Ex ec IIC T4 Gc: . Marking: II 3G Ex ec IIC T4 Gc. Galvanic isolation: . Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012. UL approval: E106378. Control drawing116-0393 (cULus): . Control drawing: 116-0393 (cULus). IECEx approval: . IECEx certificateIECEx CES 11.0010XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc: . IECEx certificate: IECEx CES 11.0010X. IECEx marking: [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specifications

General specifications

Signal typeAnalog output

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
Systematic capability (SC)SC 3

Supply

ConnectionSL1: 1a(-), 1b(-); 2a(+), 2b(+)
Rated voltage19 ... 30 V DC bus powered via Termination Board Ur
Ripple≤ 10 %
Rated current≤ 35 mA Ir
Power dissipation≤ 600 mW
Power consumption≤ 700 mW

Input

Connection sidecontrol side
ConnectionSL1: 8a(+), 7a(-)
Input signal4 ... 20 mA , limited to approx. 27 mA
Input voltagedepending on switch configurationopen loop voltage of the control system < 19 Vopen loop voltage of the control system < 26 V
Voltage dropdepending on switch configurationopen loop voltage of the control system < 19 V: approx. 5 V at 20 mAopen loop voltage of the control system < 26 V: approx. 12 V at 20 mA
Input resistance> 100 kΩ, with field wiring open

Output

Connection sidefield side
ConnectionSL2: 5a(+), 5b(-)
Voltage≥ 12.5 V at 20 mA
Current4 ... 20 mA
Load0 ... 625 Ω
Ripple20 mV rms

Transfer characteristics

Deviationat 20 °C (68 °F), 4 ... 20 mA ≤ ± 0.1 % incl. non-linearity and hysteresis
Influence of ambient temperature< 2 µA/K (0 ... 60 °C (32 ... 140 °F)); < 4 µA/K (-20 ... 0 °C (-4 ... 32 °F)) Influence of ambient temperature
Influence of ambient temperature< 2 µA/K (0 ... 60 °C (32 ... 140 °F)); < 4 µA/K (-20 ... 0 °C (-4 ... 32 °F))
Frequency rangefield side into the control side: bandwidth with 0.5 Vpp signal 0 ... 3 kHz (-3 dB) control side into the field side: bandwidth with 1 mApp signal 0 ... 3 kHz (-3 dB)
Rise time10 to 90 % ≤ 100 ms

Indicators/settings

Display elementsLED
Control elementsDIP switch
Factory settinginput: max. input voltage 19 V
Configurationvia DIP switches
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations) Directive 2014/30/EU
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2012For further information see system description.
Degree of protectionIEC 60529

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Massapprox. 100 g
Dimensions12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D)
Height106 mmWidth12.5 mmDepth128 mm Height
Height106 mm
Width12.5 mm
Depth128 mm
Mountingon termination board
Codingpin 2 and 4 trimmed For further information see system description.

Data for application in connection with hazardous areas

EU-type examination certificateCESI 11 ATEX 012
Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] IOutputEx ia Marking
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
OutputEx ia
Supply
Maximum safe voltageUm253 V AC (Attention! Um is no rated voltage.)Um Maximum safe voltage
Maximum safe voltage253 V AC (Attention! Um is no rated voltage.) Um
EquipmentSL2: 5a(+), 5b(-)
VoltageUo20 VCurrentIo100 mAPowerPo500 mWInternal capacitanceCi5.7 nFInternal inductanceLinegligibleUo Voltage
Voltage20 V Uo
Current100 mA Io
Power500 mW Po
Internal capacitance5.7 nF Ci
Internal inductancenegligible Li
Output
Maximum safe voltageUm253 V AC (Attention! The rated voltage can be lower.)Um Maximum safe voltage
Maximum safe voltage253 V AC (Attention! The rated voltage can be lower.) Um
CertificateCESI 19 ATEX 050 X
Marking II 3G Ex ec IIC T4 Gc Marking
MarkingII 3G Ex ec IIC T4 Gc
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 VInput/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V Input/Output
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Input/power supplysafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 Directive 2014/34/EU
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012

International approvals

UL approvalE106378
Control drawing116-0393 (cULus) Control drawing
Control drawing116-0393 (cULus)
IECEx approval
IECEx certificateIECEx CES 11.0010XIECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc IECEx certificate
IECEx certificateIECEx CES 11.0010X
IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex ec IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote