What is the Pepperl Fuchs HD2-GTR-4PA.PN?
Gateway PROFINET RT to 4 x PROFIBUS PA segments
Up to 32 devices per PROFIBUS PA segment
Installation in Zone 2/Class I, Div. 2
Ring and system redundancy
Integrated webserver for diagnostics
Gateway module for fieldbus power hub for PROFINET to PROFIBUS PA communication, Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 283822 |
| Design / Mounting | Motherboard based |
| Installation in hazardous area | Zone 2 / Div. 2 |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Supply
| Rated voltage | 19.2 ... 35 V SELV/PELV Ur |
| Rated current | typ. 135 mA Ir |
| Power dissipation | approx. 3.5 W |
Fieldbus connection
| Number of segments | 4 |
| Number of devices per segment | max. 32 |
| Fieldbus type | PROFIBUS PA |
Ethernet Interface
| Number of ports | 2 |
| Protocol | PROFINET |
| Ethernet Interface | Connector plug , 2x RJ45 |
| Transfer rate | 100 MBit/s |
| Redundancy | Ring (MRP) , System S2 |
Indicators/operating means
| LED ETH1 LINK 2 | green: link status |
| LED ETH1 ACT | yellow: activity status |
| LED ETH2 LINK | green: link status |
| LED ETH2 ACT | yellow: activity status |
| LED ERR | red 2 Hz flashing: Ethernet error |
| LED Seg 1...4 | red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error |
| LED PWR | green: Power on |
| LED DP/ERR | red 2 Hz flashing: DP error ; red: Hardware error |
| LED Red. | yellow: redundant operation primary device ; yellow 2 Hz flashing: synchronization or redundancy not available |
Galvanic isolation
| CH/PROFIBUS DP | functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff |
| PROFIBUS DP/Supply | functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff |
| CH/CH | functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff |
| CH/Ethernet | functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff |
| All circuits/FE | functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff |
| Ethernet/Supply | functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity
| Electromagnetic compatibility | NE 21:2011 |
| Degree of protection | IEC 60529 |
| Fieldbus standard | IEC 61158-2 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) vertically mounted , -40 ... 70 °C (-40 ... 158 °F) horizontally mounted |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | < 95 % non-condensing |
| Shock resistance | 15 g 11 ms |
| Vibration resistance | 1 g , 10 ... 150 Hz |
| Pollution degree | max. 2, according to IEC 60664 |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Housing material | Polycarbonate |
| Degree of protection | IP20 |
| Mass | 250 g |
| Dimensions: Height | 106 mm |
| Dimensions: Width | 40 mm |
| Dimensions: Depth | 128 mm |
| Mounting | motherboard mounting |
Data for application in connection with hazardous areas
| Certificate | TÜV 15 ATEX 7735 X |
| Marking | II 3 G Ex ec IIC T4 Gc |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 |
International approvals
| IECEx approval | IECEx TUR 16.0007X |
| Approved for | Ex ec IIC T4 Gc |
Certificates and approvals
| Marine approval | pending |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
HD2-GTR-4PA.PN: frequently asked questions
When can HD2-GTR-4PA.PN be shipped?
HD2-GTR-4PA.PN is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up HD2-GTR-4PA.PN in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for HD2-GTR-4PA.PN and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HD2-GTR-4PA.PN, subject to availability and destination.
More Pepperl Fuchs parts