Pepperl Fuchs FB8222B.1.EL
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | FB (Zone 1) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FB8222B.1.EL be shipped?
FB8222B.1.EL is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FB8222B.1.EL in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FB8222B.1.EL and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB8222B.1.EL, subject to availability and destination.
Gateway for PROFINET. Communication via PROFINET, Installation in suitable enclosures in Zone 1, Interface between the I/O modules and the PCS/PLC, Non-volatile memory for configuration and parameter settings, Fieldbus type: PROFINET. Connection: backplane bus. Nominal voltage: 12 V DC , only in connection with the power supplies FB92**. Power dissipation: 4.24 W. Power consumption: 4.24 W. Fieldbus type: PROFINET. Connection type: M12 , via front connector. Transfer rate: 10BASE-T, 100BASE-TX 100 MBit/s. Station connection: directly to PCS or PLC or via hubs or switches. Cable type: SFTP in accordance with ISO/IEC 11801 for Cat 5e or better. Bus length: max. 100 m per link. Addressing: DHCP or fixed IP address. Ethernet address: IP V4 address (factory standard setting: 0.0.0.0, auto IP, DHCP). Supported I/O modules: FB1x01*…FB1x03*, FB1x08*, FB1x09*, FB2x01*...FB2x17*, FB3x01*…FB3x06*, FB4x01*, FB4x02*, FB4x04*…FB4x06*, FB5x01*, FB5x02*, FB5x04*…FB5x06*, FB6x01*, FB6x05*, FB6x06*, FB6x08*, FB6x10*…FB6x17*, FB7x04. PROFINET conformance class: CC B. Connection: backplane bus. Ethernet/other circuits: basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 V DC (SELV/PELV). RS 485 interface/other circuits: basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V DC. Insulation voltage: 1500 V AC acc. to IEEE 802.3u. Power supply, internal bus/other circuits: basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 V DC. LED indication: See below in the front view. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Environmental test: EN 60068-2-14. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Damaging gas: EN 60068-2-42. Relative humidity: EN 60068-2-78. Ambient temperature: -20 ... 60 °C (-4 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 95 % non-condensing. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , a separate housing is required acc. to the system description. Connection: via backplane. Mass: approx. 965 g. Dimensions: . Height107 mmWidth57 mmDepth151 mm: . Height: 107 mm. Width: 57 mm. Depth: 151 mm. EU-type examination certificate: PTB 19 ATEX 2007 U. Marking II 2G Ex db eb ib q IIC Gb: . Marking: II 2G Ex db eb ib q IIC Gb. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015 EN 60079-11:2012: . Directive 2014/34/EU: EN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015 EN 60079-11:2012. ATEX approval: PTB 19 ATEX 2007 U. IECEx approval: . IECEx certificateIECEx PTB 19.0025UIECEx markingEx db eb ib q IIC Gb: . IECEx certificate: IECEx PTB 19.0025U. IECEx marking: Ex db eb ib q IIC Gb. System information: The module may be installed only in the associated backplanes FB9262BP*.2 in Zone 1, Zone 2, or outside the hazardous area. Observe the corresponding EC-type examination certificate.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
Supply
| Connection | backplane bus |
| Nominal voltage | 12 V DC , only in connection with the power supplies FB92** |
| Power dissipation | 4.24 W |
| Power consumption | 4.24 W |
Fieldbus connection
| Fieldbus type | PROFINET |
Ethernet Interface
| Connection type | M12 , via front connector |
| Transfer rate | 10BASE-T, 100BASE-TX 100 MBit/s |
| Station connection | directly to PCS or PLC or via hubs or switches |
| Cable type | SFTP in accordance with ISO/IEC 11801 for Cat 5e or better |
| Bus length | max. 100 m per link |
| Addressing | DHCP or fixed IP address |
| Ethernet address | IP V4 address (factory standard setting: 0.0.0.0, auto IP, DHCP) |
| Supported I/O modules | FB1x01*…FB1x03*, FB1x08*, FB1x09*, FB2x01*...FB2x17*, FB3x01*…FB3x06*, FB4x01*, FB4x02*, FB4x04*…FB4x06*, FB5x01*, FB5x02*, FB5x04*…FB5x06*, FB6x01*, FB6x05*, FB6x06*, FB6x08*, FB6x10*…FB6x17*, FB7x04 |
| PROFINET conformance class | CC B |
Internal bus
| Connection | backplane bus |
Galvanic isolation
| Ethernet/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 V DC (SELV/PELV) |
| RS 485 interface/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V DC |
| Insulation voltage | 1500 V AC acc. to IEEE 802.3u |
Electrical isolation
| Power supply, internal bus/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 V DC |
Indicators/settings
| LED indication | See below in the front view |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Environmental test | EN 60068-2-14 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Damaging gas | EN 60068-2-42 |
| Relative humidity | EN 60068-2-78 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
| Connection | via backplane |
| Mass | approx. 965 g |
| Dimensions | |
| Height107 mmWidth57 mmDepth151 mm | Height |
| Height | 107 mm |
| Width | 57 mm |
| Depth | 151 mm |
Data for application in connection with hazardous areas
| EU-type examination certificate | PTB 19 ATEX 2007 U |
| Marking II 2G Ex db eb ib q IIC Gb | Marking |
| Marking | II 2G Ex db eb ib q IIC Gb |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015 EN 60079-11:2012 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015 EN 60079-11:2012 |
International approvals
| ATEX approval | PTB 19 ATEX 2007 U |
| IECEx approval | |
| IECEx certificateIECEx PTB 19.0025UIECEx markingEx db eb ib q IIC Gb | IECEx certificate |
| IECEx certificate | IECEx PTB 19.0025U |
| IECEx marking | Ex db eb ib q IIC Gb |
General information
| System information | The module may be installed only in the associated backplanes FB9262BP*.2 in Zone 1, Zone 2, or outside the hazardous area. Observe the corresponding EC-type examination certificate. |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G