Pepperl Fuchs FB8210*
Com Unit for FOUNDATION Fieldbus Modular I/O
- MPN
- FB8210*
- Category
- FB (Zone 1)
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs FB8210*?
Interface between the I/O modules and the PCS/PLC
Com unit for 20 analog or 40 digital channels
Communication via FOUNDATION Fieldbus H1
HART communication via service bus
Configured via the process control system
Non-volatile memory for configuration and parameter settings
Quick communication set-up
Permanently self-monitoring
Outputs drive to safe state in case of failures
Supports multichannel I/O modules
Installation in suitable enclosures in Zone 1 or Zone 21
Module can be exchanged under voltage (hot swap)
Installation in suitable enclosures in Zone 1
Interface between the I/O modules and the PCS/PLC, Com unit for 20 analog or 40 digital channels, Communication via FOUNDATION Fieldbus H1, HART communication via service bus, Fieldbus type: FOUNDATION Fieldbus H1
Specifications
Supply
| Order code (Pepperl+Fuchs part number) | T42294 |
| Connection | backplane bus |
| Rated voltage | 5 V DC , only in connection with the power supplies FB92** Ur |
| Power consumption | 2 W |
| Auxiliary energy | 24 V DC Trunk load 20 mA |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Fieldbus connection
| Fieldbus type | FOUNDATION Fieldbus H1 |
| FOUNDATION Fieldbus: Connection | wired to Ex e terminals via backplane |
| FOUNDATION Fieldbus: Baud rate | 31.25 kBit/s , MBP |
| FOUNDATION Fieldbus: Protocol | H1 to IEC 1158-2 |
| Station connection | directly at the trunk or via spur protector |
| Number of channels per station | max. 20 analog, max. 40 digital |
| Supported I/O modules | 5 slots, to be filled with (combinations possible):1*08 digital input, 8-channel, NAMUR3*05 analog input, 4-channel, 20 mA (HART via service bus)4*05 analog output, 4-channel, 20 mA (HART via service bus) 5204 Pt100 RTD input, 4-channel5205 thermocouple input, 4-channel6305 relay output, 4-channel, 230 V6306 relay output, 8-channel, 24 V6*08 digital output, 8-channel, Ex i6210-6215 digital output, 4-channel, Ex i power* = variable (2=IS, 3=Ex e) |
| Bus length | max. 1900 m (must not be exceeded by the sum of all trunk and spur lines) |
| Spur length | max. 120 m (depending on the number of field devices. Modular I/O station = 1 field device) |
| Addressing | via PCS (software) |
Internal bus
| Connection | backplane bus |
Indicators/settings
| LED indication | LED green (power supply): On = operating, fast flash = cold start LED red (collective alarm): On = internal fault, flashing = no fieldbus LED yellow (operating mode): flashing = active |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | IEC 60529 |
| Fieldbus standard | IEC 61158-2 |
| Environmental test | EN 60068-2-14 |
| Shock resistance | EN 60068-2-27 |
| Vibration resistance | EN 60068-2-6 |
| Damaging gas | EN 60068-2-42 |
| Relative humidity | EN 60068-2-56 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
| Connection | via backplane |
| Mass | approx. 750 g |
| Dimensions: Height | 107 mm |
| Dimensions: Width | 57 mm |
| Dimensions: Depth | 132 mm |
Data for application in connection with hazardous areas
| EU-type examination certificate | PTB 97 ATEX 1074 U |
| Marking | II 2 G Ex d IIC Gb |
| Directive conformity: Directive 2014/34/EU | EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 |
International approvals
| ATEX approval | PTB 97 ATEX 1075 |
| EAC approval | Russia: RU C-IT.MIII06.B.00129 |
| Marine approval: Lloyd Register | 15/20021 |
| Marine approval: DNV GL Marine | TAA0000034 |
| Marine approval: American Bureau of Shipping | T1450280/UN |
| Marine approval: Bureau Veritas Marine | 22449/B0 BV |
General information
| System information | The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate. |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
FB8210*: frequently asked questions
When can FB8210* be shipped?
FB8210* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FB8210* in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FB8210* and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB8210*, subject to availability and destination.