Pepperl Fuchs FB3205B3
HART Transmitter Power Supply, Input Isolator
- MPN
- FB3205B3
- Category
- FB (Zone 1)
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs FB3205B3?
4-channel
Inputs Ex ia
Installation in suitable enclosures in Zone 1
Module can be exchanged under voltage (hot swap)
Power supply for 2-wire transmitters with 4 mA ... 20 mA
Supply circuit 15 V (20 mA)
Input from active signals of 4-wire transmitters
HART communication via field bus or service bus
Simulation mode for service operations (forcing)
Line fault detection (LFD)
Permanently self-monitoring
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
Specifications
Slots
| Order code (Pepperl+Fuchs part number) | 276318 |
| Occupied slots | 2 |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Supply
| Connection | backplane bus |
| Rated voltage | 12 V DC , only in connection with the power supplies FB92** Ur |
| Power dissipation | 1.5 W |
| Power consumption | 2.7 W |
Internal bus
| Connection | backplane bus |
| Interface | manufacturer-specific bus to standard com unit |
Analog input
| Number of channels | 4 |
| Suitable field devices: Field device | pressure converter |
| Suitable field devices: Field device [2] | flow converter |
| Suitable field devices: Field device [3] | level converter |
| Suitable field devices: Field device [4] | Temperature Converter |
| Field device interface: Connection | 2-wire transmitter |
| Field device interface: Connection [2] | 3-wire transmitter |
| Field device interface: Connection [3] | 4-wire transmitter |
| Connection | 2-wire transmitter (HART):Supply circuit: channel I 1+, 2-, channel II 5+, 6-, channel III 9+, 10-, channel IV 13+, 14-3-wire transmitter:Supply circuit: channel I 1+, 4-, channel II 5+, 8-, channel III 9+, 12-, channel IV 13+, 16-Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-4-wire transmitter (powered externally):Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16- |
| Transmitter supply voltage | min. 15 V at 20 mA ; 21.5 V at 4 mA |
| Input resistance | 15 Ω |
| Conversion time | max. 100 ms |
| Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool |
| Short-circuit | factory setting: > 22 mA configurable between 0 ... 26 mA |
| Open-circuit | factory setting: < 1 mA configurable between 0 ... 26 mA |
| HART communication | yes |
| HART secondary variable | no |
Transfer characteristics
| Deviation: After calibration | 0.1 % of the signal range at 20 °C (68 °F) |
| Deviation: Influence of ambient temperature | 0.1 %/10 K of the signal range |
| Resolution | 12 Bit (0 ... 26 mA) |
| Refresh time | 100 ms |
Indicators/settings
| LED indication | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) |
| Coding | optional mechanical coding via front socket |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 |
Conformity
| Electromagnetic compatibility | NE 21:2007 |
| Degree of protection | IEC 60529:2000 |
| Environmental test | EN 60068-2-14:2009 |
| Shock resistance | EN 60068-2-27:2009 |
| Vibration resistance | EN 60068-2-6:2008 |
| Damaging gas | EN 60068-2-42:2003 |
| Relative humidity | EN 60068-2-78:2001 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
| Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) |
| Mass | approx. 955 g |
| Dimensions: Height | 107 mm |
| Dimensions: Width | 57 mm |
| Dimensions: Depth | 132 mm |
Data for application in connection with hazardous areas
| EU-type examination certificate | Presafe 19 ATEX 14056U |
| Marking | II 2(1)G Ex db eb q [ia Ga] IIC Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I |
| Supply: Voltage | 27 V Uo |
| Supply: Current | 90 mA Io |
| Supply: Power | 588 mW (linear characteristic) Po |
| Input: Voltage | 0.7 V Uo |
| Input: Current | 2.78 mA Io |
| Input: Power | 2 mW (trapezoid characteristic curve) Po |
| Input: Voltage | 30 V DC Ui |
| Input: Current | 100 mA Ii |
| Input: Power | 100 mW Pi < 100 mW is fulfilled by Ii < 100 mA, so a comparison of Po < Pi is not necessary. Pi |
| Input: Internal capacitance | 242 nF Ci |
| Input: Internal inductance | 0 mH Li |
| Galvanic isolation: Input/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012 |
International approvals
| ATEX approval | Presafe 19 ATEX 14056U |
| IECEx approval: IECEx certificate | IECEx PRE 19.0011U |
| IECEx approval: IECEx marking | Ex db eb q [ia Ga] IIC Gb [Ex ia Da] IIIC [Ex ia Ma] I |
General information
| System information | The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (8)
- China SITIIAS CCC Ex Certificate (2021322310004066 (Mannheim))
- EU Declaration of Conformity (Pepperl+Fuchs)
- DNV Marine (TAA0000034)
- Brasil TUV Rheinland Brazil (TÜV 19.0478 U)
- Korea KOSHA (20-AV4BO-0406U)
- United Kingdom CML UK-Type Examination Certificate UKEX Category (1) D UKEX Category (1) G UKEX Category (M1) (CML 23UKEX2149U)
- Europe Presafe DNV GL ATEX I (M1) II (1) D II 2(1)G (Presafe 19 ATEX 14056U)
- Korea KOSHA (20-AV4BO-0403U)
FB3205B3: frequently asked questions
When can FB3205B3 be shipped?
FB3205B3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FB3205B3 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FB3205B3 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB3205B3, subject to availability and destination.