What is the Pepperl Fuchs FB3205B3?

4-channel

Inputs Ex ia

Installation in suitable enclosures in Zone 1

Module can be exchanged under voltage (hot swap)

Power supply for 2-wire transmitters with 4 mA ... 20 mA

Supply circuit 15 V (20 mA)

Input from active signals of 4-wire transmitters

HART communication via field bus or service bus

Simulation mode for service operations (forcing)

Line fault detection (LFD)

Permanently self-monitoring

4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication

Specifications

Slots

Order code (Pepperl+Fuchs part number)276318
Occupied slots2
LifecycleActive (current Pepperl+Fuchs product)

Supply

Connectionbackplane bus
Rated voltage12 V DC , only in connection with the power supplies FB92** Ur
Power dissipation1.5 W
Power consumption2.7 W

Internal bus

Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit

Analog input

Number of channels4
Suitable field devices: Field devicepressure converter
Suitable field devices: Field device [2]flow converter
Suitable field devices: Field device [3]level converter
Suitable field devices: Field device [4]Temperature Converter
Field device interface: Connection2-wire transmitter
Field device interface: Connection [2]3-wire transmitter
Field device interface: Connection [3]4-wire transmitter
Connection2-wire transmitter (HART):Supply circuit: channel I 1+, 2-, channel II 5+, 6-, channel III 9+, 10-, channel IV 13+, 14-3-wire transmitter:Supply circuit: channel I 1+, 4-, channel II 5+, 8-, channel III 9+, 12-, channel IV 13+, 16-Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-4-wire transmitter (powered externally):Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-
Transmitter supply voltagemin. 15 V at 20 mA ; 21.5 V at 4 mA
Input resistance15 Ω
Conversion timemax. 100 ms
Line fault detectioncan be switched on/off for each channel via configuration tool , configurable via configuration tool
Short-circuitfactory setting: > 22 mA configurable between 0 ... 26 mA
Open-circuitfactory setting: < 1 mA configurable between 0 ... 26 mA
HART communicationyes
HART secondary variableno

Transfer characteristics

Deviation: After calibration0.1 % of the signal range at 20 °C (68 °F)
Deviation: Influence of ambient temperature0.1 %/10 K of the signal range
Resolution12 Bit (0 ... 26 mA)
Refresh time100 ms

Indicators/settings

LED indicationPower LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit)
Codingoptional mechanical coding via front socket

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013

Conformity

Electromagnetic compatibilityNE 21:2007
Degree of protectionIEC 60529:2000
Environmental testEN 60068-2-14:2009
Shock resistanceEN 60068-2-27:2009
Vibration resistanceEN 60068-2-6:2008
Damaging gasEN 60068-2-42:2003
Relative humidityEN 60068-2-78:2001

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Connectionremovable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Massapprox. 955 g
Dimensions: Height107 mm
Dimensions: Width57 mm
Dimensions: Depth132 mm

Data for application in connection with hazardous areas

EU-type examination certificatePresafe 19 ATEX 14056U
MarkingII 2(1)G Ex db eb q [ia Ga] IIC Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I
Supply: Voltage27 V Uo
Supply: Current90 mA Io
Supply: Power588 mW (linear characteristic) Po
Input: Voltage0.7 V Uo
Input: Current2.78 mA Io
Input: Power2 mW (trapezoid characteristic curve) Po
Input: Voltage30 V DC Ui
Input: Current100 mA Ii
Input: Power100 mW Pi < 100 mW is fulfilled by Ii < 100 mA, so a comparison of Po < Pi is not necessary. Pi
Input: Internal capacitance242 nF Ci
Input: Internal inductance0 mH Li
Galvanic isolation: Input/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015+A1:2018 EN 60079-11:2012

International approvals

ATEX approvalPresafe 19 ATEX 14056U
IECEx approval: IECEx certificateIECEx PRE 19.0011U
IECEx approval: IECEx markingEx db eb q [ia Ga] IIC Gb [Ex ia Da] IIIC [Ex ia Ma] I

General information

System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

FB3205B3: frequently asked questions

When can FB3205B3 be shipped?

FB3205B3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FB3205B3 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FB3205B3 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FB3205B3, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs FB1308B3 – Digital Input
Pepperl Fuchs
FB1308B3

Digital Input

Pepperl Fuchs FB2216E3 – Digital Output with Position Feedback
Pepperl Fuchs
FB2216E3

Digital Output with Position Feedback

Pepperl Fuchs FB3202B2 – HART Transmitter Power Supply, Input Isolator
Pepperl Fuchs
FB3202B2

HART Transmitter Power Supply, Input Isolator

Pepperl Fuchs FB3202B3 – HART Transmitter Power Supply, Input Isolator
Pepperl Fuchs
FB3202B3

HART Transmitter Power Supply, Input Isolator

Pepperl Fuchs FB4202B3 – HART Output Isolator
Pepperl Fuchs
FB4202B3

HART Output Isolator

Pepperl Fuchs FB4205B3 – HART Output Isolator
Pepperl Fuchs
FB4205B3

HART Output Isolator

Pepperl Fuchs FB5204B3 – RTD Converter
Pepperl Fuchs
FB5204B3

RTD Converter

Pepperl Fuchs FB5205B3 – Thermocouple Converter
Pepperl Fuchs
FB5205B3

Thermocouple Converter

Pepperl Fuchs FB3205B3Price and lead time confirmed within 1 business day
Request a Quote