Quick facts
| Availability | Confirmed on request |
| Category | Safety Control Units |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can AOS 124 be shipped?
AOS 124 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up AOS 124 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for AOS 124 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for AOS 124, subject to availability and destination.
Safety control unit. Safety control unit, one OSE input, LED display indicators, for door leaf mounting, relay output and test input, Function: Switch device for sensor supply, Operating voltage: 19 ... 35 V DC <BR>19 ... 30 V AC, Output type: relay, change-over contact, Connection: screw terminals , lead cross section 2 x 1 mm<sup>2</sup>. Marking: CE. Function indicator: two yellow indicator LEDs when both light up, the NO is closed and the NC is open. Operating voltage: 19 ... 35 V DC 19 ... 30 V AC. Power consumption: < 1 VA. Test input: Circuit with voltage > 6 V , pull-down 57 kOhm , invertable with X3 jumper. Output type: relay, change-over contact. Switching voltage: 50 V AC/DC. Switching current: 0.6 A. Energized/De-energized delay: typ. 100 ms. Response time: ≤ 20 ms. Functional safety: ISO 13849-1 Cat. 2 when using the test input ISO 13849-1 Cat. 1 without testing. Product standard: EN 61000-6-2, EN 61000-6-3. Ambient temperature: -20 ... 55 °C (-4 ... 131 °F). Storage temperature: -20 ... 55 °C (-4 ... 131 °F). Degree of protection: IP65. Connection: screw terminals , lead cross section 2 x 1 mm2. Material: . HousingPolycarbonate: . Housing: Polycarbonate. Mass: 105 g. Dimensions: . Height52 mmWidth123 mmDepth45 mm: . Height: 52 mm. Width: 123 mm. Depth: 45 mm
Specifications
General specifications
| Marking | CE |
Indicators/operating means
| Function indicator | two yellow indicator LEDs when both light up, the NO is closed and the NC is open |
Electrical specifications
| Operating voltage | 19 ... 35 V DC 19 ... 30 V AC UB |
| Power consumption | < 1 VA P0 |
Input
| Test input | Circuit with voltage > 6 V , pull-down 57 kOhm , invertable with X3 jumper |
Output
| Output type | relay, change-over contact |
| Switching voltage | 50 V AC/DC |
| Switching current | 0.6 A |
| Energized/De-energized delay | typ. 100 ms |
| Response time | ≤ 20 ms |
Conformity
| Functional safety | ISO 13849-1 Cat. 2 when using the test input ISO 13849-1 Cat. 1 without testing |
| Product standard | EN 61000-6-2, EN 61000-6-3 |
Ambient conditions
| Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) |
| Storage temperature | -20 ... 55 °C (-4 ... 131 °F) |
Mechanical specifications
| Degree of protection | IP65 |
| Connection | screw terminals , lead cross section 2 x 1 mm2 |
| Material | |
| HousingPolycarbonate | Housing |
| Housing | Polycarbonate |
| Mass | 105 g |
| Dimensions | |
| Height52 mmWidth123 mmDepth45 mm | Height |
| Height | 52 mm |
| Width | 123 mm |
| Depth | 45 mm |