Available on request

FR-F720PJ-7.5KF Mitsubishi FREQROL inverter FR-F700PJ

MPN: FR-F720PJ-7.5KF · Brand: Mitsubishi Electric (Factory Automation)
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryMitsubishi FREQROL inverter – FREQROL-F700PJ
LifecycleActive mature
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FR-F720PJ-7.5KF be shipped?

FR-F720PJ-7.5KF is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FR-F720PJ-7.5KF in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FR-F720PJ-7.5KF and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-F720PJ-7.5KF, subject to availability and destination.

The Mitsubishi Electric FR-F720PJ-7.5KF is a FR-F700PJ in the FREQROL inverter. cULus CE(LVD). Mitsubishi Electric has announced its discontinuation (2027/01 To be discontinued) — plan spares now; PartnerPLC also sources it on the surplus market after the end of order. Specifications and manuals below are Mitsubishi Electric's own data.

Specifications

Product

SeriesFREQROL inverter
CategoryFR-F700PJ
Sales status2027/01 To be discontinued (Mitsubishi Electric)
OutlinecULus CE(LVD)

Specifications

SeriesFR-F700PJ
TypeThree-phase 200 V class With Filterpack
Model nameFR-F720PJ-7.5KF
Inverter capacity (kW)7.5
Applicable motor capacity (kW) *17.5
Output: Rated capacity (kVA) *212.1
Output: Rated current (A)31.8
Output: Overload current rating *3120 % 60 s, 150 % 0.5 s (inverse-time characteristics)
Output: Voltage *4Three-phase 200 to 240 V
Power supply: Rated input AC voltage and frequencyThree-phase 200 to 240 V 50 Hz/60 Hz
Power supply: Permissible AC voltage fluctuation170 to 264 V 50 Hz/60 Hz
Power supply: Permissible frequency fluctuation±5 %
Power supply: Power supply capacity (kVA) with DC reactor *511.0
Protective structure: JEM 1030IP00
Cooling systemForced air
Approx. mass (kg)8.1
Control: Control method: CommonHigh carrier frequency PWM control
Control: Control method: Induction motorV/F control/Optimum excitation control/General-purpose magnetic flux vector control
Control: Control method: PM motorIPM motor control
Control: Output frequency range: Induction motor0.2 to 400 Hz
Control: Frequency setting and resolution: Analog input0.06 Hz/60 Hz (terminals 2 and 4 : 0 to 10 V/10-bit) 0.12 Hz/60 Hz (terminals 2 and 4 : 0 to 5 V/9-bit) 0.06 Hz/60 Hz (terminal 4 : 0 to 20 mA/10-bit)
Control: Frequency setting and resolution: Digital input0.01 Hz
Control: Frequency accuracy: Analog inputWithin ±1 % of the maximum output frequency (25 °C±10 °C)
Control: Frequency accuracy: Digital input0.01 % or less of the set output frequency
Control: Voltage/frequency characteristicsBase frequency can be set from 0 to 400 Hz. Constant-torque/variable-torque pattern can be selected.
Control: Starting torque: Induction motor120 % or more (at 1 Hz)...when General-purpose magnetic flux vector control and slip compensation is set
Control: Starting torque: PM motor50 %
Control: Torque boostManual torque boost
Control: Acceleration/deceleration time setting0.1 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration modes are available.
Control: Regenerative braking torque: Induction motor15 % *6
Control: Regenerative braking torque: PM motor5 % (10 % for 1.5 kW or less) *6
Control: DC injection brake: Induction motorOperation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) can be changed.
Control: Stall prevention operation levelOperation current : 0 to 150 % variable, with selectable availability of the function
Operation: Frequency setting signal: Number of analog input2
Operation: Frequency setting signal: Specification of analog inputTerminal 2 : 0 to 10 V/0 to 5 V Terminal 4 : 0 to 10 V/0 to 5 V/4 to 20 mA
Operation: Frequency setting signal: Digital inputThe signal is entered from the operation panel or parameter unit. Frequency setting increment can be set.
Operation: Start signalForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Operation: Input signal: Number of input signal (Contact input)5
Operation: Input signal: Input terminal function selectable signalThe following signals can be assigned to Pr. 178 to Pr.182 (input terminal function selection) : multi-speed selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, external thermal input, PU-External operation switchover, V/F switchover, output stop, start self-holding selection, forward rotation, reverse rotation comm
Operation: Operational functionMaximum and minimum frequency settings, Frequency jump, External thermal relay input selection, Automatic restart after instantaneous power failure, Forward/reverse rotation prevention, Remote setting, Second function, Multi-speed operation, Regeneration avoidance, Slip compensation, Operation mode selection, Offline auto tuning function, PID control, RS-485 communication, Optimum excitation contr
Operation: Output signal: Number of output signal (Open collector output)1
Operation: Output signal: Number of output signal (Relay output)1
Operation: Output signal: Output terminal function selectable signalThe following signals can be assigned to Pr.190 and Pr.192 (output terminal function selection) : inverter operation, up-tofrequency, overload alarm, output frequency detection, regenerative brake prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, fa
Indication: For indication on external meters: Number of output signal for indication on external meters1
Indication: For indication on external meters: Pulse train output (FM type inverter)The following signals can be assigned to Pr. 54 FM terminal function selection: output frequency, output current (steady), output voltage, frequency setting, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value, reference voltage output, motor load factor, PID set point, energy saving effect
Indication: Operation panel Parameter unit (FR-PU07): Status monitoringThe following operating status can be displayed : output frequency, output current (steady), output voltage, frequency setting, cumulative energization time, actual operation time, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value, motor load factor, PID set point, PID measured value, PID
Indication: Operation panel Parameter unit (FR-PU07): Fault monitoringFault record is displayed when a fault occurs. Past 8 fault definitions (output voltage/current/frequency/cumulative energization time right before the fault occurs) are stored.
Indication: Operation panel Parameter unit (FR-PU07): Interactive guidanceFunction (help) for operation guide *9
Protective/warning function: Protective functionOvercurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay functio
Protective/warning function: Warning functionFan alarm *7 , Stall prevention (overcurrent), Stall prevention (overvoltage), PU stop, Parameter write error, Regenerative brake pre-alarm *10 , Electronic thermal relay function pre-alarm, Maintenance timer *10 , Undervoltage, Operation panel lock, Password locked, Inverter reset
Environment: Surrounding air temperature-10 °C to +50 °C (non-freezing) *11
Environment: Surrounding air humidity90 % RH or less (non-condensing)
Environment: Storage temperature *12-20 °C to +65 °C
Environment: AmbienceIndoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)
Environment: Altitude/vibrationMaximum 1000 m, 5.9 m/s 2 or less *13 at 10 to 55 Hz in X, Y, and Z directions
NetworkRS-485 : Mitsubishi inverter protocol, MODBUS RTU

Downloads & documentation

Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.

Data sheets & manuals

FR-F700PJ INSTRUCTION MANUAL(BASIC) (IB-0600425ENG-B)PDF · 4.65MB
FR-F700PJ INSTRUCTION MANUAL(Applied) (IB-0600426ENG-B)PDF · 17.80MB
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Mitsubishi Electric (Factory Automation) parts

FR-F720PJ-3.7KF Mitsubishi FREQROL inverter FR-F700PJAvailable on requestFR-F720PJ-3.7KF Mitsubishi FREQROL inverter FR-F700PJ
MPN: FR-F720PJ-3.7KF · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F720PJ-5.5K Mitsubishi FREQROL inverter FR-F700PJAvailable on requestFR-F720PJ-5.5K Mitsubishi FREQROL inverter FR-F700PJ
MPN: FR-F720PJ-5.5K · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F720PJ-5.5KF Mitsubishi FREQROL inverter FR-F700PJAvailable on requestFR-F720PJ-5.5KF Mitsubishi FREQROL inverter FR-F700PJ
MPN: FR-F720PJ-5.5KF · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F720PJ-7.5K Mitsubishi FREQROL inverter FR-F700PJAvailable on requestFR-F720PJ-7.5K Mitsubishi FREQROL inverter FR-F700PJ
MPN: FR-F720PJ-7.5K · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F740PJ-0.4K Mitsubishi FREQROL inverter FR-F700PJAvailable on requestFR-F740PJ-0.4K Mitsubishi FREQROL inverter FR-F700PJ
MPN: FR-F740PJ-0.4K · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F740PJ-0.4KF Mitsubishi FREQROL inverter FR-F700PJAvailable on requestFR-F740PJ-0.4KF Mitsubishi FREQROL inverter FR-F700PJ
MPN: FR-F740PJ-0.4KF · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F740PJ-0.75K Mitsubishi FREQROL inverter FR-F700PJAvailable on requestFR-F740PJ-0.75K Mitsubishi FREQROL inverter FR-F700PJ
MPN: FR-F740PJ-0.75K · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-F740PJ-0.75KF Mitsubishi FREQROL inverter FR-F700PJAvailable on requestFR-F740PJ-0.75KF Mitsubishi FREQROL inverter FR-F700PJ
MPN: FR-F740PJ-0.75KF · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote