FR-F720PJ-7.5K Mitsubishi FREQROL inverter FR-F700PJ
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi FREQROL inverter – FREQROL-F700PJ |
| Lifecycle | Active mature |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FR-F720PJ-7.5K be shipped?
FR-F720PJ-7.5K is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FR-F720PJ-7.5K in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FR-F720PJ-7.5K and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-F720PJ-7.5K, subject to availability and destination.
The Mitsubishi Electric FR-F720PJ-7.5K is a FR-F700PJ in the FREQROL inverter. cULus CE(LVD). Mitsubishi Electric has announced its discontinuation (2027/01 To be discontinued) — plan spares now; PartnerPLC also sources it on the surplus market after the end of order. Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | FREQROL inverter |
| Category | FR-F700PJ |
| Sales status | 2027/01 To be discontinued (Mitsubishi Electric) |
| Outline | cULus CE(LVD) |
Specifications
| Series | FR-F700PJ |
| Type | Three-phase 200 V class Without Filterpack |
| Model name | FR-F720PJ-7.5K |
| Inverter capacity (kW) | 7.5 |
| Applicable motor capacity (kW) *1 | 7.5 |
| Output: Rated capacity (kVA) *2 | 12.1 |
| Output: Rated current (A) | 31.8 |
| Output: Overload current rating *3 | 120 % 60 s, 150 % 0.5 s (inverse-time characteristics) |
| Output: Voltage *4 | Three-phase 200 to 240 V |
| Power supply: Rated input AC voltage and frequency | Three-phase 200 to 240 V 50 Hz/60 Hz |
| Power supply: Permissible AC voltage fluctuation | 170 to 264 V 50 Hz/60 Hz |
| Power supply: Permissible frequency fluctuation | ±5 % |
| Power supply: Power supply capacity (kVA) without DC reactor *5 | 17.0 |
| Protective structure: JEM 1030 | IP20 |
| Cooling system | Forced air |
| Approx. mass (kg) | 3.6 |
| Control: Control method: Common | High carrier frequency PWM control |
| Control: Control method: Induction motor | V/F control/Optimum excitation control/General-purpose magnetic flux vector control |
| Control: Control method: PM motor | IPM motor control |
| Control: Output frequency range: Induction motor | 0.2 to 400 Hz |
| Control: Frequency setting and resolution: Analog input | 0.06 Hz/60 Hz (terminals 2 and 4 : 0 to 10 V/10-bit) 0.12 Hz/60 Hz (terminals 2 and 4 : 0 to 5 V/9-bit) 0.06 Hz/60 Hz (terminal 4 : 0 to 20 mA/10-bit) |
| Control: Frequency setting and resolution: Digital input | 0.01 Hz |
| Control: Frequency accuracy: Analog input | Within ±1 % of the maximum output frequency (25 °C±10 °C) |
| Control: Frequency accuracy: Digital input | 0.01 % or less of the set output frequency |
| Control: Voltage/frequency characteristics | Base frequency can be set from 0 to 400 Hz. Constant-torque/variable-torque pattern can be selected. |
| Control: Starting torque: Induction motor | 120 % or more (at 1 Hz)...when General-purpose magnetic flux vector control and slip compensation is set |
| Control: Starting torque: PM motor | 50 % |
| Control: Torque boost | Manual torque boost |
| Control: Acceleration/deceleration time setting | 0.1 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration modes are available. |
| Control: Regenerative braking torque: Induction motor | 15 % *6 |
| Control: Regenerative braking torque: PM motor | 5 % (10 % for 1.5 kW or less) *6 |
| Control: DC injection brake: Induction motor | Operation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) can be changed. |
| Control: Stall prevention operation level | Operation current : 0 to 150 % variable, with selectable availability of the function |
| Operation: Frequency setting signal: Number of analog input | 2 |
| Operation: Frequency setting signal: Specification of analog input | Terminal 2 : 0 to 10 V/0 to 5 V Terminal 4 : 0 to 10 V/0 to 5 V/4 to 20 mA |
| Operation: Frequency setting signal: Digital input | The signal is entered from the operation panel or parameter unit. Frequency setting increment can be set. |
| Operation: Start signal | Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected. |
| Operation: Input signal: Number of input signal (Contact input) | 5 |
| Operation: Input signal: Input terminal function selectable signal | The following signals can be assigned to Pr. 178 to Pr.182 (input terminal function selection) : multi-speed selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal, external thermal input, PU-External operation switchover, V/F switchover, output stop, start self-holding selection, forward rotation, reverse rotation comm |
| Operation: Operational function | Maximum and minimum frequency settings, Frequency jump, External thermal relay input selection, Automatic restart after instantaneous power failure, Forward/reverse rotation prevention, Remote setting, Second function, Multi-speed operation, Regeneration avoidance, Slip compensation, Operation mode selection, Offline auto tuning function, PID control, RS-485 communication, Optimum excitation contr |
| Operation: Output signal: Number of output signal (Open collector output) | 1 |
| Operation: Output signal: Number of output signal (Relay output) | 1 |
| Operation: Output signal: Output terminal function selectable signal | The following signals can be assigned to Pr.190 and Pr.192 (output terminal function selection) : inverter operation, up-tofrequency, overload alarm, output frequency detection, regenerative brake prealarm, electronic thermal relay function prealarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, fa |
| Indication: For indication on external meters: Number of output signal for indication on external meters | 1 |
| Indication: For indication on external meters: Pulse train output (FM type inverter) | The following signals can be assigned to Pr. 54 FM terminal function selection: output frequency, output current (steady), output voltage, frequency setting, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value, reference voltage output, motor load factor, PID set point, energy saving effect |
| Indication: Operation panel Parameter unit (FR-PU07): Status monitoring | The following operating status can be displayed : output frequency, output current (steady), output voltage, frequency setting, cumulative energization time, actual operation time, converter output voltage, regenerative brake duty, electronic thermal relay function load factor, output current peak value, converter output voltage peak value, motor load factor, PID set point, PID measured value, PID |
| Indication: Operation panel Parameter unit (FR-PU07): Fault monitoring | Fault record is displayed when a fault occurs. Past 8 fault definitions (output voltage/current/frequency/cumulative energization time right before the fault occurs) are stored. |
| Indication: Operation panel Parameter unit (FR-PU07): Interactive guidance | Function (help) for operation guide *9 |
| Protective/warning function: Protective function | Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay functio |
| Protective/warning function: Warning function | Fan alarm *7 , Stall prevention (overcurrent), Stall prevention (overvoltage), PU stop, Parameter write error, Regenerative brake pre-alarm *10 , Electronic thermal relay function pre-alarm, Maintenance timer *10 , Undervoltage, Operation panel lock, Password locked, Inverter reset |
| Environment: Surrounding air temperature | -10 °C to +50 °C (non-freezing) *11 |
| Environment: Surrounding air humidity | 90 % RH or less (non-condensing) |
| Environment: Storage temperature *12 | -20 °C to +65 °C |
| Environment: Ambience | Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) |
| Environment: Altitude/vibration | Maximum 1000 m, 5.9 m/s 2 or less *13 at 10 to 55 Hz in X, Y, and Z directions |
| Network | RS-485 : Mitsubishi inverter protocol, MODBUS RTU |
Downloads & documentation
Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.
Data sheets & manuals
| FR-F700PJ INSTRUCTION MANUAL(BASIC) (IB-0600425ENG-B) | PDF · 4.65MB |
| FR-F700PJ INSTRUCTION MANUAL(Applied) (IB-0600426ENG-B) | PDF · 17.80MB |
More Mitsubishi Electric (Factory Automation) parts
Available on requestFR-F720PJ-3.7K Mitsubishi FREQROL inverter FR-F700PJ
Available on requestFR-F720PJ-3.7KF Mitsubishi FREQROL inverter FR-F700PJ
Available on requestFR-F720PJ-5.5K Mitsubishi FREQROL inverter FR-F700PJ
Available on requestFR-F720PJ-5.5KF Mitsubishi FREQROL inverter FR-F700PJ
Available on requestFR-F720PJ-7.5KF Mitsubishi FREQROL inverter FR-F700PJ
Available on requestFR-F740PJ-0.4K Mitsubishi FREQROL inverter FR-F700PJ
Available on requestFR-F740PJ-0.4KF Mitsubishi FREQROL inverter FR-F700PJ
Available on requestFR-F740PJ-0.75K Mitsubishi FREQROL inverter FR-F700PJ