FR-E820-0050-5-60 Mitsubishi FREQROL inverter FR-E800
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi FREQROL inverter – FREQROL-E800 |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FR-E820-0050-5-60 be shipped?
FR-E820-0050-5-60 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FR-E820-0050-5-60 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FR-E820-0050-5-60 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-E820-0050-5-60, subject to availability and destination.
The Mitsubishi Electric FR-E820-0050-5-60 is a FR-E800 in the FREQROL inverter. cULus CE(LVD). Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | FREQROL inverter |
| Category | FR-E800 |
| Outline | cULus CE(LVD) |
Specifications
| Series | FR-E800 |
| Type | Three-phase 200 V class Standard model |
| Model name | FR-E820-0050-5-60 |
| Inverter capacity (kW) | 0.75 |
| Applicable motor capacity (kW) *1: LD | 1.1 |
| Applicable motor capacity (kW) *1: ND | 0.75 |
| Output: Rated capacity (kVA) *2: LD | 2.4 |
| Output: Rated capacity (kVA) *2: ND | 2.0 |
| Output: Rated current (A) *7: LD | 6.0 (5.1) |
| Output: Rated current (A) *7: ND | 5.0 (4.1) |
| Output: Overload current rating *3: LD | 120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C |
| Output: Overload current rating *3: ND | 150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C |
| Output: Voltage *4 | Three-phase 200 to 240 V |
| Output: Regenerative braking: Brake transistor | Built-in |
| Output: Regenerative braking: Maximum brake torque (ND reference) *5 | 100 % |
| Power supply: Rated input AC voltage and frequency | Three-phase 200 to 240 V, 50/60 Hz (283 to 339 VDC *9 ) |
| Power supply: Permissible AC voltage fluctuation | 170 to 264 V, 50/60 Hz (240 to 373 VDC *9 ) |
| Power supply: Permissible frequency fluctuation | ±5 % |
| Power supply: Rated input current (A) without DC reactor *8: LD | 8.2 |
| Power supply: Rated input current (A) without DC reactor *8: ND | 7.0 |
| Power supply: Rated input current (A) with DC reactor *8: LD | 6.0 |
| Power supply: Rated input current (A) with DC reactor *8: ND | 5.0 |
| Power supply: Power supply capacity (kVA) without DC reactor *6: LD | 3.1 |
| Power supply: Power supply capacity (kVA) without DC reactor *6: ND | 2.7 |
| Power supply: Power supply capacity (kVA) with DC reactor *6: LD | 2.3 |
| Power supply: Power supply capacity (kVA) with DC reactor *6: ND | 1.9 |
| Protective structure: IEC 60529 | IP20 |
| Cooling system | Natural |
| Approx. mass (kg) | 1.0 |
| Control: Control method: Common | Soft-PWM control/High carrier frequency PWM control |
| Control: Control method: Induction motor | Selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *10 |
| Control: Control method: PM motor | PM sensorless vector control |
| Control: Output frequency range: Induction motor | 0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *10 .) |
| Control: Output frequency range: PM motor | 0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency) |
| Control: Frequency setting and resolution: Analog input | 0.015 Hz/60 Hz at 0 to 10 V/12 bits (terminals 2 and 4) 0.03 Hz/60 Hz at 0 to 5 V/11 bits or 0 to 20 mA/11 bits (terminals 2 and 4) |
| Control: Frequency setting and resolution: Digital input | 0.01 Hz |
| Control: Frequency accuracy: Analog input | Within ±0.2 % of the maximum output frequency (25 °C ±10 °C) |
| Control: Frequency accuracy: Digital input | 0.01 % or less of the set output frequency |
| Control: Voltage/frequency characteristics | Base frequency can be set from 0 to 590 Hz. Constant-torque/variable-torque pattern can be selected (with induction motor only). |
| Control: Starting torque: Induction motor | The following is the specifications for the ND rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V/F control) 150 % at 0.5 Hz (Advanced magnetic flux vector control) 200 % at 0.3 Hz (0.1K to 3.7K), 150 % at 0.3 Hz (5.5K or higher) (Real sensorless vector control) 200 % at 0 Hz (0.1K to 3.7K), 150 % at 0 Hz (5.5K or higher) (Vector control *10 ) |
| Control: Starting torque: PM motor | The following is the specifications for the ND rating. 50 % (with a motor other than MM-GKR or EM-A) 200 % (with MM-GKR or EM-A) |
| Control: Torque boost | Manual torque boost (induction motor only) |
| Control: Acceleration/deceleration time setting | 0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration modes are available. |
| Control: DC injection brake: Induction motor | Operation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable |
| Control: DC injection brake: PM motor | Operation time (0 to 10 s) variable. Operating voltage (operating current) fixed. |
| Control: Stall prevention operation level | Operation current : 0 to 200 % variable, with selectable availability of the function |
| Control: Torque limit level | Torque limit value can be set (0 to 400 % variable). (Real sensorless vector control, Vector control *10 , PM sensorless vector control) |
| Operation: Frequency setting signal: Number of analog input | 2 |
| Operation: Frequency setting signal: Specification of analog input | Terminals 2 and 4 : 0 to 10 V/0 to 5 V/4 to 20 mA (0 to 20 mA) |
| Operation: Frequency setting signal: Digital input | Input using the operation panel. Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX E kit is installed). |
| Operation: Start signal | Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected. |
| Operation: Input signal: Number of input signal (Contact input) | 7 |
| Operation: Input signal: Input terminal function selectable signal | Low-speed operation command, Middle-speed operation command, High-speed operation command, Output stop, Forward rotation command, Reverse rotation command, Inverter reset The signal to be input can be changed using Pr.178 to Pr.184 (Input terminal function selection). |
| Operation: Operational function | Maximum and minimum frequency settings, Multi-speed operation, Acceleration/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, Frequency jump, Rotation display, Automatic restart after instantaneous power failure, Remote setting, Automatic accelerat |
| Operation: Output signal: Number of output signal (Open collector output) | 2 |
| Operation: Output signal: Number of output signal (Relay output) | 1 |
| Operation: Output signal: Output terminal function selectable signal | Inverter running, Up to frequency, Fault The signal to be output can be changed using Pr.190 to Pr.192 (Output terminal function selection). |
| Operation: Output signal: Pulse train output (FM type inverter) | Not used |
| Operation: Output signal: Analog output (AM type inverter) | -10 to +10 V/12 bits |
| Protective/warning function: Protective function | Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay functio |
| Protective/warning function: Warning function | Fan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Regenerative brake pre-alarm *11 , Electronic thermal relay function pre-alarm, PU stop, Maintenance timer, Parameter write error, Operation panel lock *11 , Password locked *11 , Speed limit indication *11 , Stroke limit warning *11 , Home position return setting error *11 , Home position return uncompleted *11 , Safety st |
| Environment: Surrounding air temperature | -20 °C to +60 °C (The rated current must be reduced at a temperature above 50 °C.) |
| Environment: Surrounding air humidity | 95 % RH or less (non-condensing) |
| Environment: Storage temperature *12 | -40 °C to +70 °C |
| Environment: Ambience | Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) |
| Environment: Altitude/vibration | Maximum 3000 m *13 , 5.9 m/s 2 or less at 10 to 55 Hz in X, Y, and Z directions |
| Network | RS-485 : Mitsubishi inverter protocol, MODBUS RTU, BACnet MS/TP Option unit : CC-Link, DeviceNet, PROFIBUS-DPV0 |
Downloads & documentation
Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.
Data sheets & manuals
More Mitsubishi Electric (Factory Automation) parts
Available on requestFR-E820-0030SCEPA-60 Mitsubishi FREQROL inverter FR-E800
Available on requestFR-E820-0030SCEPB-60 Mitsubishi FREQROL inverter FR-E800
Available on requestFR-E820-0030SCEPC-60 Mitsubishi FREQROL inverter FR-E800
Available on requestFR-E820-0050-4-60 Mitsubishi FREQROL inverter FR-E800
Available on requestFR-E820-0050EPA-60 Mitsubishi FREQROL inverter FR-E800
Available on requestFR-E820-0050EPB-60 Mitsubishi FREQROL inverter FR-E800
Available on requestFR-E820-0050EPC-60 Mitsubishi FREQROL inverter FR-E800
Available on requestFR-E820-0050SCEPA-60 Mitsubishi FREQROL inverter FR-E800