Keyence GC-S1R

Safety relay output unit. . Series: Safety Controller. Series code: GC series

MPN
GC-S1R
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Keyence parts? We buy surplus →

What is the Keyence GC-S1R?

Safety relay output unit. GC-S1R. Series: Safety Controller. Series code: GC series

Specifications

Specifications

Model NameSafety relay output unit
Model CodeGC-S1R
Series TitleSafety Controller
Series CodeGC series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57359&dlModelId=PM_269S1R&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/safety/safety-controller/gc/downloads/?mode=cd&modelId=PM_269S1R
Manuals URLhttps://www.keyence.com/products/safety/safety-controller/gc/downloads/?mode=ma&modelId=PM_269S1R
ModelGC-S1R
Input/output points - Safety inputs-
Input/output points - Safety relay output1 (3a)
Input/output points - AUX outputs-
Safety relay output specifications - Output typeRelay (3a) (Externally-protected outputs)*1
Safety relay output specifications - Rated load (resistance load)250 VAC 6A / 30 VDC 6A*2
Safety relay output specifications - Rated load (inductive load)240 VAC 2A (AC-15) / 24 VDC 1A (DC-13)
Safety relay output specifications - Relay output mechanical lifeResistance load (250 VAC 6A/30 VDC 6A): Min. 100,000 timesResistance load (250 VAC 1A/30 VDC 1 A): Min. 500,000 timesInductive load (AC-15: 240 VAC 2 A): Min. 100,000 times (cosø = 0.3)Inductive load (DC-13: 24 VDC 1 A): Min. 100,000 times (L/R = 48 ms)
Safety relay output specifications - Maximum cable lengthMax. 100 m 328.1'
Safety relay output specifications - B10dWith rated load: 400,000With low load: 2,000,000
Test output specifications - Output type-
Applicable standards - EMCEMS: IEC 61131-2/-6, EN61131-2/-6,EMI: IEC 61131-2, FCC Part15B Class A, ICES-003, Class A
Applicable standards - SafetyIEC 61508, EN 61508 SIL3, IEC62061 SIL CL3, ISO/EN 13849-1:2015 Cat. 4, PL e, UL1998
Dimensions39.6×95×90 mm 1.56"×3.74"×3.54" (W×D×H)
Power supply - Power voltage-
Power supply - Power consumptionMax. 80 mA
Environmental resistance - Ambient temperature−10 to +55 °C 14 to 131 °F (No freezing)
Environmental resistance - Relative humidity5 to 85% (No condensation)
Environmental resistance - Storage temperature-25 to +70 °C -13 to 158 °F (No freezing)
Environmental resistance - Operating altitudeMax. 2000 m 6561.7'
Environmental resistance - Overvoltage categoryII (III for relay output part)
Environmental resistance - Pollution degree2
Environmental resistance - Vibration resistanceFrequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14"Frequency: 9 to 150 Hz, Acceleration: 10 m/s210 times each in X, Y, Z directions
Environmental resistance - Shock resistanceAcceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions
MaterialPolycarbonate
WeightApprox. 180 g

GC-S1R: frequently asked questions

When can GC-S1R be shipped?

GC-S1R is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up GC-S1R in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for GC-S1R and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for GC-S1R, subject to availability and destination.

More Keyence parts

Keyence GC-RP30 – Remote I/O module power cable 30 m. . Series: Safety Controller. Series code: GC series
Keyence
GC-RP30

Remote I/O module power cable 30 m.

Keyence GC-RS10 – Remote I/O module extension cable 10 m. . Series: Safety Controller. Series code: GC series
Keyence
GC-RS10

Remote I/O module extension cable 10 m.

Keyence GC-RS30 – Remote I/O module extension cable 30 m. . Series: Safety Controller. Series code: GC series
Keyence
GC-RS30

Remote I/O module extension cable 30 m.

Keyence GC-S16 – Safety input unit. . Series: Safety Controller. Series code: GC series
Keyence
GC-S16

Safety input unit. . Series: Safety Controller. Series…

Keyence GC-S84 – Safety input / output unit. . Series: Safety Controller. Series code: GC series
Keyence
GC-S84

Safety input / output unit.

Keyence GL-FB1000 – GL-R Series robust floor mounting column Length 1029 mm.
Keyence
GL-FB1000

GL-R Series robust floor mounting column Length 1029 mm.

Keyence GL-FB1400 – GL-R Series robust floor mounting column Length 1429 mm.
Keyence
GL-FB1400

GL-R Series robust floor mounting column Length 1429 mm.

Keyence GL-FB1900 – GL-R Series robust floor mounting column Length 1929 mm.
Keyence
GL-FB1900

GL-R Series robust floor mounting column Length 1929 mm.

Keyence GC-S1RPrice and lead time confirmed within 1 business day
Request a Quote