What is the Keyence GC-S16?

Safety input unit. GC-S16. Series: Safety Controller. Series code: GC series

Specifications

Specifications

Model NameSafety input unit
Model CodeGC-S16
Series TitleSafety Controller
Series CodeGC series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57359&dlModelId=PM_269S16&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/safety/safety-controller/gc/downloads/?mode=cd&modelId=PM_269S16
Manuals URLhttps://www.keyence.com/products/safety/safety-controller/gc/downloads/?mode=ma&modelId=PM_269S16
ModelGC-S16
Input/output points - Safety inputs16
Input/output points - Safety outputs-
Input/output points - Test outputs4
Safety input specifications - Input deviceContact output device or PNP output device
Safety input specifications - Input typeType3
Safety input specifications - ON level (voltage/current)Min. 11 V/2 mA
Safety input specifications - OFF level (voltage/current)Max. 5 V/1.5 mA
Safety input specifications - Short-circuit currentApprox. 5 mA
Safety input specifications - Protection circuitSurge protection circuit, wrong wiring protection circuit
Safety input specifications - Maximum cable lengthMax. 100 m 328.1'
Safety output specifications - Output type-
Test output specifications - Output typePNP transistor output*1
Test output specifications - Maximum load current100 mA*1
Test output specifications - Protection circuitOvercurrent protection circuit, reverse connection protection circuit*1
Test output specifications - Maximum cable lengthMax. 100 m 328.1'*2*1
AUX output specifications - Output type-
Applicable standards - EMCEMS: IEC 61131-2/-6, EN61131-2/-6,EMI: IEC 61131-2, FCC Part15B Class A, ICES-003, Class A
Applicable standards - SafetyIEC 61508, EN 61508 SIL3, IEC62061 SIL CL3, ISO/EN 13849-1:2015 Cat. 4, PL e, UL1998
Dimensions22.2×95×90 mm 0.87"×3.74"×3.54" (W×D×H)
Power supply - Power voltage-
Power supply - Power consumptionMax. 50 mA
Environmental resistance - Ambient temperature−10 to +55 °C 14 to 131 °F (No freezing)
Environmental resistance - Relative humidity5 to 85% (No condensation)
Environmental resistance - Storage temperature-25 to +70 °C -13 to 158 °F (No freezing)
Environmental resistance - Operating altitudeMax. 2000 m 6561.7'
Environmental resistance - Overvoltage categoryII
Environmental resistance - Pollution degree2
Environmental resistance - Vibration resistanceFrequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14"Frequency: 9 to 150 Hz, Acceleration: 10 m/s210 times each in X, Y, Z directions
Environmental resistance - Shock resistanceAcceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions
MaterialPolycarbonate
WeightApprox. 130 g

GC-S16: frequently asked questions

When can GC-S16 be shipped?

GC-S16 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up GC-S16 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for GC-S16 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for GC-S16, subject to availability and destination.

More Keyence parts

Keyence GC-RP10 – Remote I/O module power cable 10 m. . Series: Safety Controller. Series code: GC series
Keyence
GC-RP10

Remote I/O module power cable 10 m.

Keyence GC-RP30 – Remote I/O module power cable 30 m. . Series: Safety Controller. Series code: GC series
Keyence
GC-RP30

Remote I/O module power cable 30 m.

Keyence GC-RS10 – Remote I/O module extension cable 10 m. . Series: Safety Controller. Series code: GC series
Keyence
GC-RS10

Remote I/O module extension cable 10 m.

Keyence GC-RS30 – Remote I/O module extension cable 30 m. . Series: Safety Controller. Series code: GC series
Keyence
GC-RS30

Remote I/O module extension cable 30 m.

Keyence GC-S1R – Safety relay output unit. . Series: Safety Controller. Series code: GC series
Keyence
GC-S1R

Safety relay output unit.

Keyence GC-S84 – Safety input / output unit. . Series: Safety Controller. Series code: GC series
Keyence
GC-S84

Safety input / output unit.

Keyence GL-FB1000 – GL-R Series robust floor mounting column Length 1029 mm.
Keyence
GL-FB1000

GL-R Series robust floor mounting column Length 1029 mm.

Keyence GL-FB1400 – GL-R Series robust floor mounting column Length 1429 mm.
Keyence
GL-FB1400

GL-R Series robust floor mounting column Length 1429 mm.

Keyence GC-S16Price and lead time confirmed within 1 business day
Request a Quote