IFM SD6101
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Systems for the consumption measurement of compressed air & industrial gases |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can SD6101 be shipped?
SD6101 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SD6101 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SD6101 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SD6101, subject to availability and destination.
Precise measurement of flow, consumption and medium temperature High accuracy, repeatability and measurement dynamics For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2) With switching output, analogue output and pulse output Clearly visible 4-digit LED display Convenient operation via buttons or parameter setting via IO-Link
Specifications
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
| Process connection | threaded connection 1/2" NPT external thread DN15 |
| Measuring range | 10...2650 scfh; 0.15...44.15 scfm; 1...339.5 sfs |
| 15...4310 scfh | 0.2...71.8 scfm |
| 10...2640 scfh | 0.15...44 scfm |
| 10...2650 scfh | 0.15...44.15 scfm |
Application
| Application | for industrial applications |
| Media | Argon (Ar); carbon dioxide (CO2); nitrogen (N2) |
| Medium temperature[°F] [°F] | 32...140 |
| Pressure rating | 16 bar; 232 psi; 1.6 MPa |
| 16 bar | 232 psi |
| MAWP for applications according to CRN[bar] [bar] | 16 |
Electrical data
| Operating voltage[V] [V] | 18...30 DC; (to SELV/PELV) |
| Current consumption[mA] [mA] | < 100 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 1 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
| Total number of outputs | 2 |
| Output signal | switching signal; analogue signal; pulse signal; IO-Link; (configurable) |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250; (per output) |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20; (scalable) |
| Max. load[Ω] [Ω] | 500 |
| Pulse output | consumed quantity meter |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Low flow cut-off LFC | < 46 scfh; < 0.76 scfm; 1...5.8 sfs |
| < 46 scfh | < 0.76 scfm |
| Measuring dynamics | 1:300 |
| Pulse value | 0.040...4 000 000 scf |
| In steps of | 5 scfh; 0.05 scfm; 0.5 sfs |
| Pulse length[s] [s] | 0,007...2 |
| Measuring range | 10...2650 scfh; 0.15...44.15 scfm; 1...339.5 sfs |
| 15...4310 scfh | 0.2...71.8 scfm |
| Display range | 0...3175 scfh; 0...52.95 scfm; 0...407.5 sfs |
| 0...5170 scfh | 0...86.2 scfm |
| Resolution | 5 scfh; 0.05 scfm; 0.5 sfs |
| 5 scfh | 0.05 scfm |
| Set point SP | 25...2650 scfh; 0.4...44.15 scfm; 3...339.5 sfs |
| 40...4310 scfh | 0.7...71.8 scfm |
| Reset point rP | 15...2635 scfh; 0.2...43.95 scfm; 1.5...338 sfs |
| 20...4290 scfh | 0.4...71.5 scfm |
| Analogue start point ASP | 0...2120 scfh; 0...35.3 scfm; 0...271.5 sfs |
| 0...3445 scfh | 0...57.4 scfm |
| Analogue end point AEP | 530...2650 scfh; 8.85...44.15 scfm; 68...339.5 sfs |
| 860...4310 scfh | 14.4...71.8 scfm |
| 10...2640 scfh | 0.15...44 scfm |
| 0...3170 scfh | 0...52.8 scfm |
| 25...2640 scfh | 0.4...44 scfm |
| 15...2630 scfh | 0.2...43.8 scfm |
| 0...2110 scfh | 0...35.2 scfm |
| 530...2640 scfh | 8.8...44 scfm |
| 10...2650 scfh | 0.15...44.15 scfm |
| 0...3175 scfh | 0...52.95 scfm |
| 25...2650 scfh | 0.4...44.15 scfm |
| 15...2635 scfh | 0.2...43.95 scfm |
| 0...2120 scfh | 0...35.3 scfm |
| 530...2650 scfh | 8.85...44.15 scfm |
| Measuring range[°F] [°F] | 32...140 |
| Display range[°F] [°F] | 10.5...161.5 |
| Resolution[°F] [°F] | 0.5 |
| Set point SP[°F] [°F] | 32.5...140 |
| Reset point rP[°F] [°F] | 32...139.5 |
| Analogue start point[°F] [°F] | 32...118.5 |
| Analogue end point[°F] [°F] | 53.5...140 |
| In steps of[°F] [°F] | 0.5 |
Accuracy / deviations
| Repeatability[% of the measured value] [% of the measured value] | ± 1,5 |
| Accuracy (in the measuring range) | ± (6 % MW + 0,6 % MEW); (conditions: installation to DIN ISO 2533; installation in pipes: DN15) |
| Accuracy[K] [K] | ± 2; (medium flow in the limit area of the flow measurement range) |
Response times
| Response time[s] [s] | 0.1; (dAP = 0) |
| Damping process value dAP in steps[s] [s] | 0 - 0,2 - 0,4 - 0,6 - 0,8 - 1 |
Software / programming
| Parameter setting options | Flow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; medium selection |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Device diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Process data analogue | 3 |
| Process data binary | 2 |
| Min. process cycle time[ms] [ms] | 4.1 |
| Supported DeviceIDs | default; 266 |
| default | 266 |
Operating conditions
| Ambient temperature[°F] [°F] | 32...140 |
| Storage temperature[°F] [°F] | -4...185 |
| Max. relative air humidity[%] [%] | 90 |
| Protection | IP 65 |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Vibration resistance | DIN IEC 68-2-6; 5 g (55...2000 Hz) |
| DIN IEC 68-2-6 | 5 g (55...2000 Hz) |
| MTTF[years] [years] | 227 |
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight[g] [g] | 925.5 |
| Housing | rectangular |
| Dimensions[mm] [mm] | 300 x 45 x 79.5 |
| Materials | PBT-GF20; PC; PC; stainless steel (304/1.4301); FKM |
| Materials (wetted parts) | stainless steel (304/1.4301); ceramics glass passivated; PEEK; polyester; FKM; aluminium anodised |
| Process connection | threaded connection 1/2" NPT external thread DN15 |
Displays / operating elements
| Display | Display unit; 4 x LED, green (scfm, scfh, scf, °F); function display; 1 x LED, yellow; switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit |
| Display unit | scfm; scfh; scf; °F |
| function display | 1 x LED, yellow |
| switching status | 2 x LED, yellow |
| measured values | alphanumeric display, 4-digit |
| programming | alphanumeric display, 4-digit |
Remarks
| Remarks | MW = measured value; MEW = Final value of the measuring range; Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533. |
| Pack quantity | 1 pcs. |
Electrical connection
| Connector | 1 x M12; coding: A |