IFM SD6050

MPN
SD6050
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the IFM SD6050?

Precise measurement of flow, consumption and medium temperature

High accuracy, repeatability and measurement dynamics

For detecting compressed air in industrial use

With switching output, analogue output and pulse output

Clearly visible 4-digit LED display

Convenient operation via buttons or parameter setting via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range10...1250 l/min; 0.3...103.6 m/s; 0.2...75 m³/h
10...1250 l/min0.3...103.6 m/s
Process connectionthreaded connection G 1/2 internal thread DN15

Application

Applicationfor industrial applications
Mediacompressed air
Medium temperature[°C] [°C]0...60
Pressure rating16 bar; 1.6 MPa
16 bar1.6 MPa

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 110
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]1

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range10...1250 l/min; 0.3...103.6 m/s; 0.2...75 m³/h
10...1250 l/min0.8...103.6 m/s
Display range0...1500 l/min; 0...124.3 m/s; 0...90 m³/h
0...1500 l/min0...124.3 m/s
Set point SP10...1250 l/min; 0.8...103.6 m/s; 0.6...75 m³/h
Reset point rP4...1244 l/min; 0.3...103.1 m/s; 0.2...74.6 m³/h
4...1244 l/min0.3...103.1 m/s
Analogue start point ASP0...938 l/min; 0...77.7 m/s; 0...56.3 m³/h
0...938 l/min0...77.7 m/s
Analogue end point AEP312...1250 l/min; 25.9...103.6 m/s; 18.7...75 m³/h
312...1250 l/min25.9...103.6 m/s
In steps of0.001 m³
1 l/min0.1 m/s
Pulse value0.001...1000000 m³
Pulse length[s] [s]0,02...2
Measuring range[°C] [°C]0...60
Display range[°C] [°C]-12...72

Accuracy / deviations

Repeatability[% of the measured value] [% of the measured value]± 1,5
Accuracy (in the measuring range)± (15 % MW + 1,5 % MEW); (maximum value to be achieved for air quality class 344 (DIN 8573-1); when using pipes of tolerance class T3/T4; inlet and outlet pipe lengths without edges and abrupt diameter changes; inner surface of the pipe free of burrs)
Accuracy[K] [K]± 2; (medium flow in the limit area of the flow measurement range)

Response times

Response time[s] [s]0.1; (dAP = 0)
Damping process value dAP in steps[s] [s]0 - 0,2 - 0,4 - 0,6 - 0,8 - 1

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]4.1
Supported DeviceIDsdefault; 262
default262

Operating conditions

Ambient temperature[°C] [°C]0...60
Storage temperature[°C] [°C]-20...85
Max. relative air humidity[%] [%]90
ProtectionIP 65

Tests / approvals

EMCDIN EN 61000-6-2; DIN EN 61000-6-3
CPA approvalmodel number; 004TG; accuracy class; -; maximum allowable error; ± 16,5 % FS; Q (min); 0,2 m³/h; Q (t); -; Q (max); 75 m³/h
model number004TG
accuracy class-
maximum allowable error± 16,5 % FS
Q (min)0,2 m³/h
Q (t)-
Q (max)75 m³/h
Vibration resistanceDIN EN 68000-2-6; 5 g (55...2000 Hz)
DIN EN 68000-2-65 g (55...2000 Hz)
MTTF[years] [years]227
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]579
Housingrectangular
Dimensions[mm] [mm]111 x 45 x 80.4
MaterialsPBT-GF20; NBR; PC; stainless steel (304/1.4301); PTFE; brass coated; FKM; aluminium powder-coated
Materials (wetted parts)stainless steel (304/1.4301); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium
Tightening torque[Nm] [Nm]50
Process connectionthreaded connection G 1/2 internal thread DN15

Displays / operating elements

DisplayDisplay unit; 5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C); function display; 1 x LED, green; switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit
Display unit5 x LED, green (Nl/min, Nm³/h, Nm/s, Nm³, °C)
function display1 x LED, green
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range; Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions.
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A

SD6050: frequently asked questions

When can SD6050 be shipped?

SD6050 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SD6050 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SD6050 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SD6050, subject to availability and destination.

More IFM parts

IFM SD6050Price and lead time confirmed within 1 business day
Request a Quote