IFM SA3010

MPN
SA3010
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare IFM parts? We buy surplus →

What is the IFM SA3010?

Reliable monitoring of water in pipes

Two switching outputs, one of them programmable as analogue output

Easy setting of the switch points for quick set-up

Robust housing for use in harsh industrial environments

LED display for indication of the measured value

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range[l/min] [l/min]0...10
Process connectionthreaded connection M26 x 1,5 internal thread

Application

Special featureGold-plated contacts
InstallationT-pieces; ((DIN 2353): QL 18-18-18 (NW 15 mm) / QL 22-18-22 (NW 19 mm) / QL 28-18-28 (NW 24 mm))
Mediawater
Medium temperature[°C] [°C]0...80
Pressure rating30 bar; 3 MPa
30 bar3 MPa

Electrical data

Operating voltage[V] [V]20...28 DC
Current consumption[mA] [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]10
Measuring principlecalorimetric

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable)
Min. load resistance[Ω] [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range[l/min] [l/min]0...10
Display range[l/min] [l/min]0...12
Set point SP[l/min] [l/min]0.1...12
Reset point rP[l/min] [l/min]0...11.9
Analogue start point ASP[l/min] [l/min]0...8
Analogue end point AEP[l/min] [l/min]4...12
In steps of[l/min] [l/min]0.1

Accuracy / deviations

Repeatability[% of the measured value] [% of the measured value]3 (Q < 30%) / 7 (Q < 100%)
Temperature gradient[K/min] [K/min]200
Accuracy (in the measuring range)± 10

Response times

Response time[s] [s]5; (10%...90%)
Delay time programmable dS, dr[s] [s]0...50

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; current/voltage output; inside pipe diameter; start-up delay; adaptation of displayed values; display can be rotated and switched off; Display unit

Operating conditions

Ambient temperature[°C] [°C]-20...60
ProtectionIP 67

Tests / approvals

EMCEN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted10 V
MTTF[years] [years]184

Mechanical data

Weight[g] [g]330.5
Housingcylindrical
Dimensions[mm] [mm]Ø 34 / L = 102
Materialsstainless steel (316L/1.4404); PBT; PC; PA; EPDM/X; FKM
Materials (wetted parts)stainless steel (316L/1.4404); O-ring: FKM 70 Shore A
Process connectionthreaded connection M26 x 1,5 internal thread
Probe diameter[mm] [mm]14

Displays / operating elements

Displayswitching status; 2 x LED, red; measured values; 7-segment LED display; programming; 7-segment LED display
switching status2 x LED, red
measured values7-segment LED display
programming7-segment LED display
Display unitl/min; gpm; l/h; gph; m³/h

Remarks

RemarksNW = nominal diameter
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

SA3010: frequently asked questions

When can SA3010 be shipped?

SA3010 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SA3010 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SA3010 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SA3010, subject to availability and destination.

More IFM parts

IFM SA3010Price and lead time confirmed within 1 business day
Request a Quote