IFM MFH220

MPN
MFH220
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the IFM MFH220?

Adjustable end position monitoring in the hydraulic cylinder

Inline quality control checks to ensure correct assembly of parts

Monitoring of critical hydraulic cylinders via switching cycles counter

High-pressure resistant up to an operating pressure of 500 bar

User-friendly communication and parameterisation via IO-Link

Specifications

Product characteristics

Electrical designPNP/NPN
Output functionnormally open / normally closed; (parameterisable)
Sensing range[mm] [mm]0...2; (Factory setting 1,65)
Communication interfaceIO-Link
Housingthreaded type
Dimensions[mm] [mm]M12 x 1 / L = 60

Application

Special featureFull-metal housing
Applicationhydraulic cylinders
Mediadetects ferrous metals
Min. burst pressure2000 bar; 200 MPa
2000 bar200 MPa
Pressure rating500 bar; 50 MPa
500 bar50 MPa

Electrical data

Operating voltage[V] [V]10...30 DC
Rated insulation voltage[V] [V]60
Current consumption[mA] [mA]< 20
Protection classIII
Reverse polarity protectionyes
Max. power-on delay time[ms] [ms]300

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]1.6
Max. leakage current[mA] [mA]0.1
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]200
Short-circuit protectionyes
Overload protectionyes

Detection zone

Sensing range[mm] [mm]0...2; (Factory setting 1,65)

Accuracy / deviations

Hysteresis[mm] [mm]0.05...0.5; (Factory setting 0,1)
Switch point drift[% of Sr] [% of Sr]10
Repeatability[% of Sr] [% of Sr]10

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1.4
SDCI standardIEC 61131-9 CDV
ProfilesSmart Sensor - SSP 4.1.1; Measuring and Switching Sensor, 1 channel; Common - I&D; Identification and Diagnosis; Extension; Object detection, switches when value falls below the setpoint; Function; ProductURI; Function; Teach single value
Smart Sensor - SSP 4.1.1Measuring and Switching Sensor, 1 channel
Common - I&DIdentification and Diagnosis
ExtensionObject detection, switches when value falls below the setpoint
FunctionTeach single value
SIO modeyes
Required master port typeA
Min. process cycle time[ms] [ms]4
Supported DeviceIDsdefault; 1950
default1950

Operating conditions

Pressure peak1000 bar; 100 MPa
1000 bar100 MPa
Ambient temperature[°C] [°C]-25...120
ProtectionIP 65; IP 66; IP 68; IP 69K

Tests / approvals

EMCEN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B; DIN ISO 11452-5; 100 V/m
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted10 V
EN 55011class B
DIN ISO 11452-5100 V/m
Vibration resistanceEN 60068-2-6 Fc; 20 g 50 sweep cycles, 1 octave per minute, in 3 axes / 10...3000 Hz -20...50 °C
EN 60068-2-6 Fc20 g 50 sweep cycles, 1 octave per minute, in 3 axes / 10...3000 Hz -20...50 °C
Shock resistanceEN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C
EN 60068-2-27 Ea40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C
Continuous shock resistanceEN 60068-2-27 Ea; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C
UL approvalTa; -25...65 °C; power supply; Limited Voltage/Current; UL approval no.; C025; File number UL; E174191
Ta-25...65 °C
power supplyLimited Voltage/Current
UL approval no.C025
File number ULE174191

Mechanical data

Weight[g] [g]30.64
Housingthreaded type
Mountingflush mountable
Dimensions[mm] [mm]M12 x 1 / L = 60
Thread designationM12 x 1
Materialshousing: stainless steel (316L / 1.4404); O-ring: FKM; supporting ring: PTFE; plug: PEI
Min. pressure cycles10 million
Tightening torque[Nm] [Nm]< 25
Full-metal housingyes

Accessories

Items suppliedlock nuts: 1 x M12

Remarks

Pack quantity1 pcs.

Electrical connection - plug

Connector1 x M12; coding: A

MFH220: frequently asked questions

When can MFH220 be shipped?

MFH220 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up MFH220 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for MFH220 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for MFH220, subject to availability and destination.

More IFM parts