What is the IFM MFH219?
Adjustable end position monitoring in the hydraulic cylinder
Inline quality control checks to ensure correct assembly of parts
Monitoring of critical hydraulic cylinders via switching cycles counter
High-pressure resistant up to an operating pressure of 500 bar
User-friendly communication and parameterisation via IO-Link
Specifications
Product characteristics
| Electrical design | PNP/NPN |
| Output function | normally open / normally closed; (parameterisable) |
| Sensing range[mm] [mm] | 0...2; (Factory setting: 1,65) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M12 x 1 / L = 55 |
Application
| Special feature | Full-metal housing |
| Application | hydraulic cylinders |
| Media | detects ferrous metals |
| Min. burst pressure | 2000 bar; 200 MPa |
| 2000 bar | 200 MPa |
| Pressure rating | 500 bar; 50 MPa |
| 500 bar | 50 MPa |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
| Rated insulation voltage[V] [V] | 60 |
| Current consumption[mA] [mA] | > 25 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time[ms] [ms] | 300 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
Outputs
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 1.6 |
| Max. leakage current[mA] [mA] | 0.1 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 200 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Sensing range[mm] [mm] | 0...2; (Factory setting: 1,65) |
Accuracy / deviations
| Hysteresis[mm] [mm] | 0.05...0.5; (Factory setting: 0,1) |
| Switch point drift[% of Sr] [% of Sr] | 10 |
| Repeatability[% of Sr] [% of Sr] | 10 |
Interfaces
| Communication interface | IO-Link |
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1.3 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 4.1.1; Measuring and Switching Sensor, 1 channel; Common - I&D; Identification and Diagnosis; Extension; Object detection, switches when value falls below the setpoint; Function; Locator; Function; ProductURI; Function; Teach channel |
| Smart Sensor - SSP 4.1.1 | Measuring and Switching Sensor, 1 channel |
| Common - I&D | Identification and Diagnosis |
| Extension | Object detection, switches when value falls below the setpoint |
| Function | Teach channel |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 4 |
| Supported DeviceIDs | default; 1905 |
| default | 1905 |
Operating conditions
| Pressure peak[bar] [bar] | 1000 |
| Ambient temperature[°C] [°C] | -25...85 |
| Protection | IP 65; IP 67; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 (80...2000 Mhz); 10 V/m; EN 61000-4-4; 2 kV; EN 61000-4-6 (0,15...80 Mhz); 10 V; EN 55011; class B; DIN ISO 11452-5; 100 V/m |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 (80...2000 Mhz) | 10 V/m |
| EN 61000-4-4 | 2 kV |
| EN 61000-4-6 (0,15...80 Mhz) | 10 V |
| EN 55011 | class B |
| DIN ISO 11452-5 | 100 V/m |
| Vibration resistance | EN 60068-2-6 Fc; 20 g 50 sweep cycles, 1 octave per minute, in 3 axes / 10...3000 Hz -20...50 °C |
| EN 60068-2-6 Fc | 20 g 50 sweep cycles, 1 octave per minute, in 3 axes / 10...3000 Hz -20...50 °C |
| Shock resistance | EN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| EN 60068-2-27 Ea | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Continuous shock resistance | EN 60068-2-27 Ea; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Salt spray test | EN 60068-2-52 Kb; severity level 5 (4 test cycles) |
| EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
| UL approval | Ta; -25...65 °C; Enclosure type; Type 1; power supply; Limited Voltage/Current; UL approval no.; C025; File number UL; E174191 |
| Ta | -25...65 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | C025 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 94.2 |
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M12 x 1 / L = 55 |
| Thread designation | M12 x 1 |
| Materials | housing: stainless steel (316L / 1.4404); O-ring: FPM; supporting ring: PTFE; plug: PEI |
| Min. pressure cycles | 10 million |
| Tightening torque[Nm] [Nm] | < 25 |
| Full-metal housing | yes |
Displays / operating elements
| Display | switching status; LED, yellow |
| switching status | LED, yellow |
Accessories
| Items supplied | lock nuts: 1 x M12 |
Remarks
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 2 m, PUR, Ø 4.9 mm; 4 x 0.34 mm² |
MFH219: frequently asked questions
When can MFH219 be shipped?
MFH219 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up MFH219 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for MFH219 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for MFH219, subject to availability and destination.