Honeywell – 79CM307.CC 79CM307Z1 Systevo Connection Board STIP
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Honeywell Nurse Call Systems |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 79CM307.CC be shipped?
79CM307.CC is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 79CM307.CC in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 79CM307.CC and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 79CM307.CC, subject to availability and destination.
Part Number: 79CM307Z1
Connection board for IP touch terminal, to provide the required nurse call system and control functions in the resident/patient room or duty room according to the nurse call standards. Serves as a control unit for additional functions in the corresponding room and as a gateway to the overriding central unit (via Data bus).
Monitoring and synchronization of the entire data traffic and audio connections (calls, announcements) to other rooms within the organizational unit, and coordination of communication with the central units and other room devices via data bus.
Configuration data of the room and used profiles (functions, I/O, device services) are managed via the management server and stored locally (redundant local flash storage), for increased safety.
Associated multifunctional room units as well as the corridor lamp, can be connected to the room controller via the integrated data bus (DBUS) as well as using the integrated call inputs (I/O).
Integration into the corridor data bus (ZBUS) and connection of the bed bus (BBUS) in backward compatibility mode (for bed call modules).
Includes an user-friendly installation technology with colour-coded connection terminals for each individual device and control functions, for a more efficient cabling and for an optimized commissioning process.
Supports bed-wise speaking in combination with an optional bed/speech unit and hand-held device at the bed.
Upgradable to future system firmware thanks to advanced flash storage technologies. Possibility for automated software update during operation.
A multi-level security concept enables local call signaling in the case of a lack of communication with the central unit of the system.
Support of the cyber security requirements of modern data bus infrastructures.
Integrates an electromechanical lock feature to secure the IP touch terminal.
System functions subject to license are provided by corresponding software licenses.
Features
Special material properties:
High quality plastic surface with antimicrobial compound for reduction of existing microorganisms and prevent their reproduction.
Good mechanical properties with high resistance to daily use (operation, cleaning, disinfection, impacts, etc.).
Suitable for use in care facilities with high demands on hygiene, stability, longevity and durability.
Plastic (PC + ABS-FR), matt
UV-resistant, impact-resistant
Heat resistance, stability
Longevity, durability, halogen free
Flame protection (fire protection class V0)
System architecture:
Processor/OS: Embedded µC system
Cyber-Security: Firewall, secured boot loader function
Configuration: via data service
Inputs/Outputs:
24V DC power supply
DBUS: 2x RS487 (200 m each) for up to 4 participants each
ABUS/ZBUS: 1x RS487 (500 m) each
BBUS: 1x RS485 (200 m)
Call input/output: 4x I/O
Connection terminals: color-coded for up to 3x 0.8 mm (0.6 mm) wires (rigid)
Galvanic isolation of the control functions according to EN 60601.1.1 through external protective measures
Honeywell 79CM307.CC — Connection board for IP touch terminal databus, to provide the required nurse call system and control functions in the resident/patient room or duty room according to the nurse call standards. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Active |
| Brand line | Honeywell |
Operating Characteristics
| Ambient Temperature | 5 to 55°C |
| Storage Temperature | -20 to 70°C |
| Minimum storage temperature (°C) | -20°C |
| Minimum ambient temperature (°C) | 5°C |
Standards & Certifications
| Type Of Protection | IP20, V0 (Fire Protection) |
| Approval | EN 60601.1.1 |
Electrical Specifications
| Power Supply | 24V DC |
| Current consumption @ 24 V DC (mA) | 180 |
| Current consumption (mA) | With IP Touch-Terminal 300, Without IP Touch-Terminal 30-40 |
Technical Specifications
| Mounting | Flush |
| Interface | Databus (DBUS) |
Material Specifications
| Material | PC + ABS-FR |
Features
| Functions | A Multi-Level Security Concept Enables Local Call Signaling in the Case of a Lack of Communication with the Central Unit of the System, Associated Multifunctional Room Units as well as the Corridor Lamp, can be Connected to the Room Controller via the Integrated Databus (DBUS) as well as Using the Integrated Call Inputs (I/O), Configuration Data of the Room and Used Profiles (Functions, I/O, Device Services) are Managed via the Management Server and Stored Locally (Redundant Local Flash Storage) for Increased Safety, Future-Oriented Flash Memory Technology to Ensure Automated Software Updates During Operation, Includes an User-Friendly Installation Technology with Colour-Coded Connection Terminals for Each Individual Device and Control Functions and for a More Efficient Cabling and for an Optimized Commissioning Process, Integrates an Electro-Mechanical Lock Feature to Secure the IP Touch Terminal, Integration Into the Corridor Databus (ZBUS) and Connection of the Bed BUS (BBUS) in Backward Compatibility Mode (For Bed Call Modules), Monitoring and Synchronization of the Entire Data Traffic and Audio Connections (Calls, Announcements) to Other Rooms within the Organizational Unit, and Coordination of Communication with the Central Units and Other Room Devices via Databus, Required Nurse Call System and Control Functions in the Resident/Patient Room or Duty Room According to the Nurse Call Standards. Serves as a Control Unit for Additional Functions in the Corresponding Room., Support of the Cyber Security Requirements of Modern Databus Infrastructures, Supports Bed-Wise Speaking in Combination with an Optional Bed/Speech Unit and Hand-Held Device at the Bed |
| Features & Benefits | ABUS/ZBUS: 1x RS487 (500 m) Each, BBUS: 1x RS485 (200 m), Call Input/Output: 4x I/O, Configuration: via Data Service, Connection Terminals: Color-Coded for up to 3x 0.8 mm (0.6 mm) Wires (Rigid), Cyber-Security: Firewall and Secured Boot-Loader Function, DBUS: 2x RS487 (200 m Each) for up to 4 Participants Each, Galvanic Isolation of the Control Functions According to EN 60601.1.1 Through External Protective Measures, Good Mechanical Properties with High Resistance to Daily Use (Operation, Cleaning, Disinfection, Jolts etc.), Heat Resistance and Stability, High Quality Plastic surface with Antimicrobial Compound for Reduction of Existing Microorganisms and Prevent Their Reproduction, Longevity, Durability, Halogen Free, Plastic (PC + ABS-FR) with Matt Finish, Processor/OS: Embedded µC System, Suitable for Use in Care Facilities with High Demands on Hygiene, Stability, Longevity and Durability, UV-Resistant and Impact-Resistant |
Dimensions & Weight
| Dimensions | W: 100 mm L: 170 mm D: 10 mm |
Overview
| Brand | Honeywell |
Others
| Industry | Healthcare |
Ordering codes
| Part numbers on this product page | 79CM307.CC, 79CM307Z1 |
More Honeywell parts
Available on request797-090 Power supply extension for DXc1-M and DXc2-M
Available on request797027 Key Switch Accessory
Available on request798655 Log book for FAS (DE/GB)