B&R X20MM3332
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Motor controllers |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can X20MM3332 be shipped?
X20MM3332 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20MM3332 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20MM3332 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20MM3332, subject to availability and destination.
3 full-bridge outputs (H-bridges)High component density3 A continuous current5 A peak currentReadable current The 3 outputs on the motor module are designed as full-bridge outputs. The continuous current per channel is 3 A at a peak current of up to 5 A. Integrated diagnostics offer the possibility to read back the output current for each channel using the application. The module offers extensive possibilities for controlling motors, valves or resistive loads and is particularly well suited for controlling brush DC motors. Because the outputs are designed as full-bridge outputs, the motors can be moved in both directions.
Specifications
Specifications
| I/O module | 3 full bridge outputs |
| B&R ID code | 0xA982 |
| Status indicators | I/O function per channel, operating state, module status |
| Module run/error | Yes, using LED status indicator and software |
| Output | Yes, using LED status indicator and software |
| I/O power supply | Yes, using LED status indicator and software |
| Bus | 0.01 W |
| Internal I/O | 0.8 W |
| External I/O | Corresponding to external load |
| Additional power dissipation caused by actuators (resistive) [W] | - |
| CE | Yes |
| UKCA | Yes |
| CRA (Cyber Resilience Act) | In preparation |
| ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| UL | cULus E115267 Industrial control equipment |
| HazLoc | cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| KC | Yes |
| Quantity | 3 |
| Variant | H bridge |
| Type | Full bridge High-side driver Low-side driver |
| Nominal voltage | 24 VDC |
| Switching voltage | 24 VDC (-15% / +20%) |
| Nominal current | 3 A |
| Maximum current | 5 A (250 ms) |
| Total nominal current | 10 A |
| Resolution | 100 mA |
| Data collection | In driver |
| Output protection | Thermal shutdown in the event of overcurrent or short circuit |
| Supply voltage | No reverse polarity protection |
| Insulation voltage between channel and bus | 500 Veff |
| External | 24 VDC power supply - maximum current 10 A (melting fuse) |
| Electrical isolation | Bus isolated from channel and internal I/O power supply Channel not isolated from channel and internal I/O power supply |
| Horizontal | Yes |
| 0 to 2000 m | No limitation |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
| Horizontal mounting orientation | 0 to 50°C |
| Vertical mounting orientation | Not permitted |
| Derating | See section "Derating". |
| Storage | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
| Operation | 5 to 95%, non-condensing |
| Note | Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately. |
| Pitch | 12.5+0.2 mm |
More B&R parts
UsedB&R 5C5001.01 IPC 5000 5D5500.06 Used
UsedB&R 5PC720.1505-K07 - 5P62:0A-03 Used