What is the B&R X20DO6325?

6 digital outputs

Source connection

2-wire connections

GND for signal supply

Integrated output protection

1-wire connection type with 6-pin terminal block

Diagnostic functions (open line, short circuit and overload/overtemperature)

OSP mode

The module is equipped with six outputs for 1 or 2-wire connections with diagnostic functions. The X20 6-pin terminal block can be used for universal 1-line wiring. Two-line wiring can be implemented using the 12-pin terminal block. The outputs on the module are designed for source connections.

Specifications

Short description

I/O module6 digital outputs 24 VDC for 1- or 2-wire connections with diagnostic function

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – Status outputsYes, using LED status indicator and software
Diagnostics – Diagnostic outputsYes, using LED status indicator and software
Power consumption – Bus0.15 W
Power consumption – Internal I/O0.4 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – DNVTemperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
Certifications – CCSYes
Certifications – LRENV1
Certifications – KRYes
Certifications – ABSYes
Certifications – BVEC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck
B&R ID code0xE284
Status indicatorsI/O function per channel, diagnostics per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]Mechanical and electrical configuration" in the X20 system user's manual.">0.225 (note: Number of outputs x R DS(on) x Nominal output current 2 . For a calculation example, see section)

Digital outputs

Diagnostic status – Open circuitAt <1 mA (typ.), detected if output OFF, delay approx. 10 ms
Diagnostic status – Short circuit to 24 VDCDetected if output OFF, delay approx. 10 ms
Diagnostic status – Short circuit to GNDDetected if output ON, delay approx. 10 ms
Diagnostic status – Overload/OvertemperatureDetected if output ON, delay approx. 10 ms
Switching delay – 0 → 1<100 μs (note: At loads ≤ 1 kΩ)
Switching delay – 1 → 0<300 μs (note: At loads ≤ 1 kΩ)
Switching frequency – Resistive loadMax. 2000 Hz (note: At loads ≤ 1 kΩ)
Switching frequency – Inductive loadSee section "Switching inductive loads".
VariantCurrent-sourcing FET
Nominal voltage24 VDC
Switching voltage24 VDC -15% / +20%
Nominal output current0.5 A
Total nominal current3 A
Connection type1- or 2-wire connections
Output circuitSource
Output protectionThermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current"); Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")
Leakage current when the output is switched off<160 μA
R DS(on)150 mΩ
Peak short-circuit current<40 A
Switch-on in the event of overload shutdown or short-circuit shutdownDepends on the module temperature
Braking voltage when switching off inductive loads45 to 52 VDC
Insulation voltage between channel and bus510 V eff

Electrical properties

Electrical isolationChannel isolated from bus; Channel not isolated from channel and I/O power supply

Operating conditions

Mounting orientation – HorizontalYes
Mounting orientation – VerticalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation-25 to 60°C
Temperature – Vertical mounting orientation-25 to 50°C
Temperature – Derating-
Temperature – Storage-40 to 85°C
Temperature – Transport-40 to 85°C
Relative humidity – Operation5 to 95%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB06 or X20TB12 separately. ; Order 1x bus module X20BM11 separately.
Pitch12.5 +0.2 mm

Accessories

Required accessories (order separately)

X20BM15Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe…
X20BM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module…
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…
X20TB06Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

CAD & dimension drawings

Certificates (14)

X20DO6325: frequently asked questions

When can X20DO6325 be shipped?

X20DO6325 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20DO6325 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20DO6325 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20DO6325, subject to availability and destination.

More B&R parts

B&R X20DO4649 – I/O module, 4 digital outputs 30 VDC / 240 VAC
B&R
X20DO4649

I/O module, 4 digital outputs 30 VDC / 240 VAC

B&R X20DO4F49 – I/O module, 4 digital outputs 250 VDC / 240 VAC
B&R
X20DO4F49

I/O module, 4 digital outputs 250 VDC / 240 VAC

B&R X20DO6321 – I/O module, 6 digital outputs 24 VDC for 1- or 2-wire…
B&R
X20DO6321

I/O module, 6 digital outputs 24 VDC for 1- or 2-wire…

B&R X20DO6322 – I/O module, 6 digital outputs 24 VDC for 1- or 2-wire…
B&R
X20DO6322

I/O module, 6 digital outputs 24 VDC for 1- or 2-wire…

B&R X20DO6529 – I/O module, 6 digital outputs 30 VDC / 115 VAC
B&R
X20DO6529

I/O module, 6 digital outputs 30 VDC / 115 VAC

B&R X20DO6639 – I/O module, 6 digital outputs 30 VDC / 240 VAC
B&R
X20DO6639

I/O module, 6 digital outputs 30 VDC / 240 VAC

B&R X20DO8232 – I/O module, 8 digital outputs 12 VDC for 1-wire connections
B&R
X20DO8232

I/O module, 8 digital outputs 12 VDC for 1-wire connections

B&R X20DO8322 – I/O module, 8 digital outputs 24 VDC for 1-wire connections
B&R
X20DO8322

I/O module, 8 digital outputs 24 VDC for 1-wire connections

B&R X20DO6325Price and lead time confirmed within 1 business day
Request a Quote