B&R X20BR7300
Bus receiver, CAN I/O slave
- MPN
- X20BR7300
- Category
- Bus receivers and transmitters
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
What is the B&R X20BR7300?
Fieldbus: CAN bus
Automatic firmware update via the fieldbus
Integrated I/O access in B&R Automation Studio
The bus receiver makes it possible to connect X2X Link I/O nodes to CAN I/O. CAN I/O is a transfer protocol based on standard CAN bus that is fully integrated in the B&R system.
Up to 43 logical I/O modules can be connected to the bus receiver. Up to 16 of these can be analog modules.
Specifications
Short description
| Bus receiver | CAN I/O slave |
General information
| Diagnostics – Module status | Yes, using LED status indicator |
| Diagnostics – Bus function | Yes, using LED status indicator |
| Diagnostics – Data transfer | Yes, using LED status indicator |
| Diagnostics – Overload | Yes, using LED status indicator and software |
| Power consumptionMechanical and electrical configuration" in the X20 system user's manual."> – Internal I/O | 1.5 W (note: The specified values are maximum values. For examples of the exact calculation, see section) |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| B&R ID code | 0xEBED |
| Status indicators | Module status, bus function, data transfer, I/O power supply, bus power supply |
| Power consumption for X2X Link power supply | 1.1 W |
| Additional power dissipation caused by actuators (resistive) [W] | - |
X2X Link and I/O power supply
| Input voltage | 24 VDC -15% / +20% |
| Fuse | Required line fuse: Max. 10 A slow-blow for wiring; Integrated fuse for module, non-replaceable |
| Reverse polarity protection | Yes |
X2X Link power supply output
| Nominal output power | 2 W |
| Parallel connection | No |
| Redundant operation | No |
| Overload characteristics | Short-circuit proof, temporary overload |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Behavior on short circuit | Required line fuse |
| Permissible contact load | 10 A |
Interfaces
| Fieldbus | CAN I/O slave |
| Variant | Connection via 12-pin terminal block X20TB12 |
| Max. distance | 1000 m |
| Transfer rate | Max. 1 Mbit/s |
| Default transfer rate | Automatic transfer rate detection |
| X2X Link cycle time | Permanently set to 1 ms (note: CAN I/O data points are processed in Automation Runtime in a separate cycle set to 10 ms (CAN I/O cycle).) |
| Synchronization between bus systems possible | No |
Electrical properties
| Electrical isolation | X2X Link supply not isolated from X2X Link power supply; I/O supply not isolated from I/O power supply; CAN I/O not isolated from I/O or X2X Link power supply |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | - |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. ; Order 1x power supply bus module X20BM01 separately, X20 end cover plates (left and right) X20AC0SL1/X20AC0SR1 included |
| Pitch | 12.5 +0.2 mm |
Accessories
Required accessories (order separately)
| X20BM05 | Bus modules — The bus module is the base for all X20 supply modules; For creating voltage groups; The internal I/O supply is isolated to the left; Manual… |
| X20BM01 | Bus modules — Basis for all power supply modules; For creating potential groups; The internal I/O power supply is interrupted to the left. The bus module… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
X20BR7300: frequently asked questions
When can X20BR7300 be shipped?
X20BR7300 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20BR7300 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20BR7300 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?