B&R 8I64T400055.00X-1

ACOPOSinverter X64, 3x 380-500 V, 0.55 kW, integrated EMC filter and brake chopper

MPN
8I64T400055.00X-1
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare B&R parts? We buy surplus →

What is the B&R 8I64T400055.00X-1?

ACOPOSinverter X64, 3x 380-500 V, 0.55 kW, integrated EMC filter and brake chopper, shield plate included in delivery, X2X Link interface

Specifications

Motor power

Specified on nameplate0.55 kW ; 0.75 PS

Mains connection

Max. mains current with optional mains choke – At 380 VAC1.4 A
Max. mains current with optional mains choke – At 500 VAC1.2 A
Max. mains current – At 380 VAC2.8 A (note: Typical value for 4-pin motor and a max. clock frequency of 4 kHz, without mains choke for the max. assumed short circuit current (lsc).)
Max. mains current – At 500 VAC2.2 A (note: Typical value for 4-pin motor and a max. clock frequency of 4 kHz, without mains choke for the max. assumed short circuit current (lsc).)
Mains input voltage3x 380 VAC -15% to 500 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 500 VAC)1.8 kVA
Max. assumed short-circuit current (Isc); (short-circuit current at connection point)5 kA (note: Add a line choke if the short-circuit current (lsc) exceeds the values in the table.)
Power dissipation at max. output current37 W
Integrated EMC filterYes

Line-conducted and radiated emissions

With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C1 environment 1 (public power network)- (note: For shielded motor cables)
With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network)≤5 m (note: For shielded motor cables)
With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C3 environment 2 (industrial power system)≤5 m (note: For shielded motor cables)
With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C1 environment 1 (public power network)≤20 m (note: For shielded motor cables)
With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network)≤50 m (note: For shielded motor cables)
With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C3 environment 2 (industrial power system)≤50 m (note: For shielded motor cables)
With add-on filter8I0FT015.200-1

Motor connection

Derating of continuous output current depending on ambient temperature – Clock frequency 4 kHzNo derating (up to 50°C)
Derating of continuous output current depending on ambient temperature – Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com.
Derating of continuous output current depending on installation elevation – Starting at 1000 m above sea level1%, per 100 m
Max. continuous output current (In) – At 500 VAC1.9 A
Nominal clock frequency – Min.2 kHz
Nominal clock frequency – Max.16 kHz
Braking torque – With braking resistor100% of the nominal motor torque continuously, up to 150% for 60 s
Braking torque – Without braking resistor (typical value)100% of the nominal motor torque
Max. motor cable length – Shielded cable50 m
Max. motor cable length – Non-shielded cable100 m
Max. transient current for 60 s2.9 A
Output frequency range0.5 to 500 Hz
Nominal clock frequency4 kHz
Short-term overload torque (typical value)170 to 200% of the nominal motor torque
Motor control profilesStandard profile (voltage/frequency ratio - V/f characteristic curve); Power profile (flux vector control without encoder); Pump/Fan profile (quadratic characteristic curve Kn²) ; Energy-saving profile (especially for ventilation)
Main protective functions of inverterThermal protection against overheating ; Protection against short circuits between motor phases ; Protection against mains phase failure, for 3-phase power supply ; Protection against motor phase failures ; Overcurrent protection between motor output phases and ground ; Overvoltage and undervoltage protection for mains supply
Motor protectionThermal protection integrated in the inverter through continually calculating the l²t value

Brake chopper

Integrated dynamic brake transistorsYes
Operating ratio for dynamic brake transistorsThe dynamic brake transistor is designed to tolerate the following values: ; -Nominal motor power continuously ; -150% of the nominal motor power for 60 s
Min. resistance value (external)80 Ω

Available internal power supplies

Output voltage – Max. output current100 mA
Output voltage24 VDC (min. 19 V, max. 30 V)

Interfaces

TypeX2X and CANopen

Digital inputs

Electrical isolation – Input - ACOPOSinverterYes
Electrical isolation – Input - InputNo
Quantity4 (2 can be used as counters)
Nominal voltage24 VDC
Input circuitSource or sink
Sampling time<4 ms
Input impedance12.1 kΩ

Counter input

Quantity2 (digital inputs - can be used as counters)
Counter frequency10 kHz
Counter size32-bit

Digital outputs

Quantity1
Nominal voltage24 VDC
Output circuitSource
Nominal output current0.5 A

Relay outputs

Switching capacity – With resistive load (cos φ = 1 and L/R = 0 ms)2 A for 250 VAC or 30 VDC
Switching capacity – With inductive load (cos φ = 0.4 and L/R = 7 ms)1.5 A for 250 VAC or 30 VDC
Switching capacity – Min.10 mA for 5 VDC
Electrical isolation – Output - ACOPOSinverterYes
Electrical isolation – Output - OutputNo
Quantity1
Variant1 NO contact
Nominal voltage30 VDC / 250 VAC
Response time (max.)<8 ms

Operating conditions

Installation elevation above sea level0 to 1000 m
Degree of protection per EN 60529IP31 and IP41 on the upper part and ; IP21 on the terminals
Ambient temperature-10 to 50°C
Max. ambient temperatureUp to +60°C (note: With reduction and removal of the top cover of the inverter. For possible mounting types and derating curves, see the installation manual available for download from www.br-automation.com.)
Relative humidity per IEC 60068-2-35 to 95%, non-condensing ; No dripping water
Maximum installation elevationUp to 2000 m (note: From 1000 to 2000 m, current reduced by 1% per 100 m)
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S2
Operating positionVertical mounting orientation ±10%

Ambient conditions

Temperature – Storage-25 to 70°C

Mechanical properties

Dimensions – Width107 mm
Dimensions – Height143 mm
Dimensions – Depth152 mm
Weight1.55 kg

Accessories

Optional accessories (3)
8I0FT015.200-1Optional EMC filters — ACOPOSinverter additional EMC input filter 3-phase 15 A, supply voltage: 380 to 480 V, 50/60 Hz
8I0BR100.000-1Optional braking resistors — Braking resistor ohmic value: 100 Ω continuous braking power: 0.05 kW degree of protection (IP): IP20
8I0CT004.000-1Optional line chokes — Mains choke 3-phase, 4 A, 50/60 for ACOPOSinverter

8I64T400055.00X-1: frequently asked questions

When can 8I64T400055.00X-1 be shipped?

8I64T400055.00X-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 8I64T400055.00X-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 8I64T400055.00X-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8I64T400055.00X-1, subject to availability and destination.

More B&R parts

B&R 8I64T400055.00X-1Price and lead time confirmed within 1 business day
Request a Quote