B&R 8I44S200220.000-1
ACOPOSinverter S44, 1x 200-240 V, 2.2 kW, integrated EMC filter, RS485 interface
- MPN
- 8I44S200220.000-1
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the B&R 8I44S200220.000-1?
ACOPOSinverter S44, 1x 200-240 V, 2.2 kW, integrated EMC filter, RS485 interface
Specifications
General information
| Certifications – CE | Yes |
| Certifications – CRA (Cyber Resilience Act) | Evaluation ongoing |
| Certifications – UL | cULus E225616; Power conversion equipment |
| Certifications – KC | Yes |
Motor power
| Specified on nameplate | 2.2 kW ; 3 HP |
Mains connection
| Max. mains current – At 200 VAC | 24 A (note: Typical value for the specified motor power and the max. assumed short-circuit current (lsc).) |
| Max. mains current – At 240 VAC | 20.2 A (note: Typical value for the specified motor power and the max. assumed short-circuit current (lsc).) |
| Mains input voltage | 1x 200 VAC -15% to 240 VAC +10% |
| Frequency | 50 to 60 Hz ±5% |
| Apparent power (at 240 VAC) | 8.4 kVA |
| Max. assumed short-circuit current (Isc); (short-circuit current at connection point) | 1000 A |
| Power dissipation at max. output current | 93 W |
| Integrated EMC filter | Yes |
Line-conducted and radiated emissions
| With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C1 environment 1 (public power network) | ≤5 m (note: For shielded motor cables, at a clock frequency of 2, 4, 8, 12 and 16 kHz) |
| With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network) | ≤5 m / ≤10 m (note: For shielded motor cables ≤5 m → At a clock frequency of 2 to 12 kHz ≤10 m → At a clock frequency of 2, 4 and 16 kHz) |
| With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C3 environment 2 (industrial power system) | ≤5 m / ≤10 m (note: For shielded motor cables ≤5 m → At a clock frequency of 2 to 12 kHz ≤10 m → At a clock frequency of 2, 4 and 16 kHz) |
| With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C1 environment 1 (public power network) | ≤20 m (note: For shielded motor cables, at a clock frequency of 2, 4, 8, 12 and 16 kHz) |
| With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network) | ≤50 m (note: For shielded motor cables) |
| With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C3 environment 2 (industrial power system) | ≤50 m (note: For shielded motor cables) |
| With add-on filter | 8I0FS024.100-1 |
Motor connection
| Derating of continuous output current depending on ambient temperature – Clock frequency 4 kHz | No derating (up to 50°C) |
| Derating of continuous output current depending on ambient temperature – Other clock frequencies | The derating curves are included in the user's manual, which can be downloaded from www.br-automation.com. |
| Derating of continuous output current depending on installation elevation – Starting at 1000 m above sea level | 1%, per 100 m |
| Max. continuous output current (In) – At 240 VAC | 10 A |
| Nominal clock frequency – Min. | 2 kHz |
| Nominal clock frequency – Max. | 16 kHz |
| Max. motor cable length – Shielded cable | 50 m |
| Max. motor cable length – Non-shielded cable | 100 m |
| Max. transient current for 60 s | 15 A |
| Output frequency range | 0.5 to 400 Hz |
| Nominal clock frequency | 4 kHz |
| Braking torque | Up to 70% of the nominal motor torque without resistance |
| Motor control profiles | Standard profile (voltage/frequency ratio - V/f characteristic curve); Power profile (flux vector control without encoder); Pump/Fan profile (quadratic characteristic curve Kn²) |
| Main protective functions of inverter | Thermal protection against overheating ; Protection against short circuits between motor phases ; Overcurrent protection between motor phases and ground ; Protection against overvoltage and undervoltage in the mains supply |
| Motor protection | Thermal protection integrated in the inverter through continually calculating the l²t value |
| Short-term overload torque | 150 to 170% of the nominal motor torque depending on inverter power and motor type |
Available internal power supplies
| Output voltage 5 VDC – Max. output current at 5 VDC | 10 mA |
| Output voltage 24 VDC – Max. output current at 24 VDC | 100 mA |
| Output voltage 5 VDC | 5 VDC ±5% |
| Output voltage 24 VDC | 24 VDC -15% / +20% |
Interfaces
| Type | Modbus RTU |
Digital inputs
| Electrical isolation – Input - ACOPOSinverter | Yes |
| Electrical isolation – Input - Input | No |
| Quantity | 4 |
| Nominal voltage | 24 VDC |
| Input circuit | Source or sink |
| Sampling time | <20 ms ±1 ms |
| Input impedance | 3.5 kΩ |
Analog inputs
| Electrical isolation – Input - Input | No |
| Electrical isolation – Input - ACOPOSinverter | Yes |
| Input impedance – Voltage | 30 kΩ |
| Input impedance – Current | 250 Ω |
| Quantity | 1 |
| Input | 0 to 5 V, 0 to 10 V or ; 0 to 20 mA |
| Resolution | 10-bit |
| Sampling time | <10 ms |
Digital outputs
| Electrical isolation – Output - ACOPOSinverter | Yes |
| Electrical isolation – Output - Output | No |
| Quantity | 1 |
| Nominal voltage | 24 VDC |
| Output circuit | Source or sink |
| Nominal output current | 10 mA (100 mA with external power supply) |
| Update time | 20 ms ±1 ms |
Relay outputs
| Switching capacity – With resistive load (cos φ = 1 and L/R = 0 ms) | 4 A at 30 VDC / 3 A at 250 VAC |
| Switching capacity – With inductive load (cos φ = 0.4 and L/R = 7 ms) | 2 A at 30 VDC or 250 VAC |
| Switching capacity – Min. | 5 mA for 24 VDC |
| Electrical isolation – Output - ACOPOSinverter | Yes |
| Electrical isolation – Output - Output | No |
| Quantity | 1 |
| Execution | 1 NO contact and 1 NC contact with a common point |
| Nominal voltage | 30 VDC / 250 VAC |
| Response time (max.) | 30 ms |
Analog outputs
| Electrical isolation – Output - ACOPOSinverter | Yes |
| Electrical isolation – Output - Output | No |
| Max. load impedance – Voltage | 470 Ω |
| Max. load impedance – Current | 800 Ω |
| Quantity | 1 |
| Output | 0 to 10 V or 0 to 20 mA |
| Update time | <10 ms |
| Resolution | 8-bit |
Operating conditions
| Installation elevation above sea level | 0 to 1000 m |
| Degree of protection per EN 60529 | IP20 |
| Ambient temperature | -10 to 50°C |
| Max. ambient temperature | Up to +60°C (note: Protective cover removed and current reduction of 2.2% per additional degree above ambient temperature. For possible mounting types and derating curves, see the operating instructions available for download from www.br-automation.com.) |
| Relative humidity per IEC 60068-2-3 | 5 to 95%, non-condensing ; No dripping water |
| Maximum installation elevation | Up to 2000 m (note: From 1000 to 2000 m, current reduced by 1% per 100 m) |
| Max. pollution degree per IEC/EN 61800-5-1 | 2 (non-conductive pollution) |
| Ambient conditions per IEC 60721-3-3 | Class 3C3 and 3S2 |
| Operating position | Vertical mounting orientation ±10% |
Ambient conditions
| Temperature – Storage | -25 to 70°C |
Mechanical properties
| Dimensions – Width | 105 mm |
| Dimensions – Height | 142 mm |
| Dimensions – Depth | 156.2 mm |
| Weight | 1.4 kg |
No matching specifications
Accessories
Optional accessories (2)
| 8I0XP002.100-1 | Undefined — Shield plate size 2, fastening clamps and screws included in delivery, for ACOPOSinverter S44 1x 100-120 V, 0.75 kW and 1x 200-240 V, 1.5-2… |
| 8I0FS024.100-1 | Undefined — Additional EMC filters are intended to reduce line-conducted emissions from the mains supply to a level under the limits specified in IEC/E… |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (1)
8I44S200220.000-1: frequently asked questions
When can 8I44S200220.000-1 be shipped?
8I44S200220.000-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8I44S200220.000-1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8I44S200220.000-1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8I44S200220.000-1, subject to availability and destination.