B&R 8I44S200037.000-1

ACOPOSinverter S44, 1x 200-240 V, 0.37 kW, integrated EMC filter, RS485 interface

MPN
8I44S200037.000-1
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare B&R parts? We buy surplus →

What is the B&R 8I44S200037.000-1?

ACOPOSinverter S44, 1x 200-240 V, 0.37 kW, integrated EMC filter, RS485 interface

Specifications

General information

Certifications – CEYes
Certifications – CRA (Cyber Resilience Act)Evaluation ongoing
Certifications – ULcULus E225616; Power conversion equipment
Certifications – KCYes

Motor power

Specified on nameplate0.37 kW ; 0.5 HP

Mains connection

Max. mains current – At 200 VAC5.9 A (note: Typical value for the specified motor power and the max. assumed short-circuit current (lsc).)
Max. mains current – At 240 VAC4.9 A (note: Typical value for the specified motor power and the max. assumed short-circuit current (lsc).)
Mains input voltage1x 200 VAC -15% to 240 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 240 VAC)2 kVA
Max. assumed short-circuit current (Isc); (short-circuit current at connection point)1000 A
Power dissipation at max. output current27 W
Integrated EMC filterYes

Line-conducted and radiated emissions

With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C1 environment 1 (public power network)≤5 m (note: For shielded motor cables, at a clock frequency of 2, 4, 8, 12 and 16 kHz)
With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network)≤5 m / ≤10 m (note: For shielded motor cables ≤5 m → at a clock frequency of 2 to 12 kHz ≤10 m → at a clock frequency of 2, 4 and 16 kHz)
With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C3 environment 2 (industrial power system)≤5 m / ≤10 m (note: For shielded motor cables ≤5 m → at a clock frequency of 2 to 12 kHz ≤10 m → at a clock frequency of 2, 4 and 16 kHz)
With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C1 environment 1 (public power network)≤20 m (note: For shielded motor cables, at a clock frequency of 2, 4, 8, 12 and 16 kHz)
With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network)≤50 m (note: For shielded motor cables)
With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C3 environment 2 (industrial power system)≤50 m (note: For shielded motor cables)
With add-on filter8I0FS011.100-1

Motor connection

Derating of continuous output current depending on ambient temperature – Clock frequency 4 kHzNo derating (up to 40°C)
Derating of continuous output current depending on ambient temperature – Other clock frequenciesThe derating curves are included in the user's manual, which can be downloaded from www.br-automation.com.
Derating of continuous output current depending on installation elevation – Starting at 1000 m above sea level1%, per 100 m
Max. continuous output current (In) – At 240 VAC2.4 A
Nominal clock frequency – Min.2 kHz
Nominal clock frequency – Max.16 kHz
Max. motor cable length – Shielded cable50 m
Max. motor cable length – Non-shielded cable100 m
Max. transient current for 60 s3.6 A
Output frequency range0.5 to 400 Hz
Nominal clock frequency4 kHz
Braking torqueUp to 70% of the nominal motor torque without resistance
Motor control profilesStandard profile (voltage/frequency ratio - V/f characteristic curve); Power profile (flux vector control without encoder); Pump/Fan profile (quadratic characteristic curve Kn²)
Main protective functions of inverterThermal protection against overheating ; Protection against short circuits between motor phases ; Overcurrent protection between motor phases and ground ; Protection against overvoltage and undervoltage in the mains supply
Motor protectionThermal protection integrated in the inverter through continually calculating the l²t value
Short-term overload torque150 to 170% of the nominal motor torque depending on inverter power and motor type

Available internal power supplies

Output voltage 5 VDC – Max. output current at 5 VDC10 mA
Output voltage 24 VDC – Max. output current at 24 VDC100 mA
Output voltage 5 VDC5 VDC ±5%
Output voltage 24 VDC24 VDC -15% / +20%

Interfaces

TypeModbus RTU

Digital inputs

Electrical isolation – Input - ACOPOSinverterYes
Electrical isolation – Input - InputNo
Quantity4
Nominal voltage24 VDC
Input circuitSource or sink
Sampling time<20 ms ±1 ms
Input impedance3.5 kΩ

Analog inputs

Electrical isolation – Input - InputNo
Electrical isolation – Input - ACOPOSinverterYes
Input impedance – Voltage30 kΩ
Input impedance – Current250 Ω
Quantity1
Input0 to 5 V, 0 to 10 V or ; 0 to 20 mA
Resolution10-bit
Sampling time<10 ms

Digital outputs

Electrical isolation – Output - ACOPOSinverterYes
Electrical isolation – Output - OutputNo
Quantity1
Nominal voltage24 VDC
Output circuitSource or sink
Nominal output current10 mA (100 mA with external power supply)
Update time20 ms ±1 ms

Relay outputs

Switching capacity – With resistive load (cos φ = 1 and L/R = 0 ms)4 A at 30 VDC / 3 A at 250 VAC
Switching capacity – With inductive load (cos φ = 0.4 and L/R = 7 ms)2 A at 30 VDC or 250 VAC
Switching capacity – Min.5 mA for 24 VDC
Electrical isolation – Output - ACOPOSinverterYes
Electrical isolation – Output - OutputNo
Quantity1
Execution1 NO contact and 1 NC contact with a common point
Nominal voltage30 VDC / 250 VAC
Response time (max.)30 ms

Analog outputs

Electrical isolation – Output - ACOPOSinverterYes
Electrical isolation – Output - OutputNo
Max. load impedance – Voltage470 Ω
Max. load impedance – Current800 Ω
Quantity1
Output0 to 10 V or 0 to 20 mA
Update time<10 ms
Resolution8-bit

Operating conditions

Installation elevation above sea level0 to 1000 m
Degree of protection per EN 60529IP20
Ambient temperature-10 to 40°C
Max. ambient temperatureUp to +60°C (note: Protective cover removed and current reduction of 2.2% per additional degree above ambient temperature. For possible mounting types and derating curves, see the operating instructions available for download from www.br-automation.com.)
Relative humidity per IEC 60068-2-35 to 95%. non-condensing; No dripping water
Maximum installation elevationUp to 2000 m (note: From 1000 to 2000 m, current reduced by 1% per 100 m)
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S2
Operating positionVertical mounting orientation ±10%

Ambient conditions

Temperature – Storage-25 to 70°C

Mechanical properties

Dimensions – Width72 mm
Dimensions – Height130 mm
Dimensions – Depth121.2 mm
Weight0.7 kg

Accessories

Optional accessories (2)
8I0XP001.100-1Undefined — Shield plate size 1, fastening clamps and screws included in delivery, for ACOPOSinverter S44 1x 100-120 V, 0.18-0.37 kW and 1x 200-240 V,…
8I0FS011.100-1Undefined — Additional EMC filters are intended to reduce line-conducted emissions from the mains supply to a level under the limits specified in IEC/E…

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

CAD & dimension drawings

Certificates (1)

8I44S200037.000-1: frequently asked questions

When can 8I44S200037.000-1 be shipped?

8I44S200037.000-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 8I44S200037.000-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 8I44S200037.000-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8I44S200037.000-1, subject to availability and destination.

More B&R parts

B&R 8I44S100018.000-1 – ACOPOSinverter S44, 1x 100-120 V, 0.18 kW, RS485 interface
B&R
8I44S100018.000-1

ACOPOSinverter S44, 1x 100-120 V, 0.18 kW, RS485 interface

B&R 8I44S100037.000-1 – ACOPOSinverter S44, 1x 100-120 V, 0.37 kW, RS485 interface
B&R
8I44S100037.000-1

ACOPOSinverter S44, 1x 100-120 V, 0.37 kW, RS485 interface

B&R 8I44S100075.000-1 – ACOPOSinverter S44, 1x 100-120 V, 0.75 kW, RS485 interface
B&R
8I44S100075.000-1

ACOPOSinverter S44, 1x 100-120 V, 0.75 kW, RS485 interface

B&R 8I44S200037.000-1Price and lead time confirmed within 1 business day
Request a Quote