INTERFACE MODULE XI812101
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | XI8 System Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can R911406094 be shipped?
R911406094 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up R911406094 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for R911406094 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for R911406094, subject to availability and destination.
The active power feeding XI812101 is used to feed in the peripheral circuitry again (UP) in a ctrlX I/O station. It supplies the connected I/O modules with the peripheral voltage (UP) of DC 24 V, 8 A, which is internally galvanically isolated from the peripheral voltage supply of the preceding modules. The voltage and the current fed in are measured internally and applied to the process data. The logic voltage supply as well as the EtherCAT-based module communication are routed through the module.
Specifications
Specifications
| Connection type | Push-in |
| Width [mm] | 20 |
| Height [mm] | 105 |
| Depth [mm] | 99 |
| International protection code | IP20 |
| Protection class | III |
| Backplane-Bus | Standard-EtherCAT über LVDS |
| EMC resistance | EN 61000-6-2 and EN 61000-6-4 |
| Bit width, input data in the process data image (including fill bits) | 6 bytes |
| Maximum power dissipation in the module [W] | 2.64 |
| Inverse polarity protection up to [V] | 50 |
| Channel LEDs | Display status of Power supply |
| Post-assembly position | Vertical, on a horizontal support rail |
| Electrical isolation | 1200 V DC UP to UL, 707 V DC UP/UL to FE, both tested for 60 s;(not evaluated by UL) |
| Fuse protection (UP) | No internal fuse protection. The operator has to provide protection against overload by an external fuse. |
| Transient protection | Present, suppressor diodes, pulse load up to 1500 W |
| Maximum number of modules per station | 30 |
| Current requirement UL | 40 mA |
| Current requirement Up | Typ. 7 mA (without I/O modules), 8 A max. (complete system with I/O modules) |
| Nominal voltage (UL/UP) | DC 24 V (19.2 V to 30 V, including tolerance and residual ripple) PELV/SELV (safety extra-low voltage) |
| Overvoltage category | 2 |
| Voltage dips at power supply interfaces | PS1 <1 ms, evaluation criterion A |
| Overvoltage protection UL and UP | Present, external fuses can trigger in case of overvoltage |
| Conductor cross-section | AWG: 24 ... 16; Flexible: 0.2-1.5 mm²; rigid: 0.2-1.5 mm² |
| Permissible air humidity (storage) [%] | 10-95 |
| Permissible air humidity (transport) [%] | 10-95 |
| Ambient temperature (storage and transport) [°C] | -40-70 |
| Ambient temperature during operation | 2,000 m to 3,000 m: -25 °C to +50 °C; 3,000 m to 4,000 m: -25 °C to +45 °C; 4,000 m to 5,000 m: -25 °C to +40 °C; Up to 2,000 m: -25 °C to +55 °C |
| Maximum operating altitude [m] | 5000 |
| Contamination level | 2, no condensation |
| Weight [kg] | 0.13 |
More Bosch Rexroth parts
UsedRexroth HCS03.1E-W0150-A-05-NNBV Used
UsedRexroth HCS01.1E-W0009 -A-02-B-ET-EC- NN-L4-NN-FW Used