Allen-Bradley – 140M-F8E-C32-KN-MT-TE Motor Protection Circuit-Breaker
Discontinued by Rockwell Automation / Allen-Bradley — we can still source the original 140M-F8E-C32-KN-MT-TE (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | 140M IEC Circuit Breakers |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
Can I still buy the 140M-F8E-C32-KN-MT-TE now that it is discontinued?
Yes. Rockwell Automation / Allen-Bradley has discontinued the 140M-F8E-C32-KN-MT-TE, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can 140M-F8E-C32-KN-MT-TE be shipped?
140M-F8E-C32-KN-MT-TE is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 140M-F8E-C32-KN-MT-TE in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 140M-F8E-C32-KN-MT-TE and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 140M-F8E-C32-KN-MT-TE, subject to availability and destination.
Allen-Bradley 140M-F8E-C32-KN-MT-TE — Motor Protection Circuit-Breaker. Discontinued by Rockwell Automation on March 31, 2025. PartnerPLC supplies new, surplus and discontinued Allen-Bradley parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Discontinued |
| Discontinued date | March 31, 2025 |
| Replacement category (Rockwell) | Engineering Replacement |
| Repair options available | No |
Specifications
| Amperage Rating | 23 - 32A,MxRtg MCPs(no OvPrt)is 1200.0A |
| Ambient operating temperature | -25 °C |
| Ambient storage temperature | -40 °C |
| Ambient temperature compensation | -25 °C |
| Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC | No back-up fuse required @ 230/240V AC |
| Breaking capacity | High breaking capacity |
| Climatic resistance | Operating humidity/moisture heat (60068-2-3): 5...95% non-condensing |
| Contactor size, min | 100-C30, UL-508 -Type E self-protected combination motor controller |
| Contactor size (Type 2 coordination) with 100-C IEC contactor, min | 100-C30 @ 600V |
| Current range | 23...32 A |
| Degree of protection (IP) | IP2X |
| Dependence on temperature | No reduction @ 60 °C (140 °F) |
| Depth | 110 mm |
| Device construction | Built-in device fixed built-in technique |
| Electrical life cycle | 30000 ops (Ie maximum) |
| Factory option | UL508 Type E spacing module |
| Frame size | Frame size F, 45 A |
| Fuse or circuit breaker per NEC, max | 600 A, UL 60947-4-1-manual motor controller |
| Fuse or circuit breaker rating with 100-C IEC contactor per NEC, max | 600 A, UL 60947-4-1-manual motor controller |
| Height | 111.4 mm |
| Hp rating, max | 7.5kA @ 230V, 3-phase |
| Insulation voltage (Ui) | Rated 690V per IEC |
| KW rating, max | 25 kW @ 690V (AC-3), 3-phase |
| Magnetic release current (±20 %) | Fixed setting: 18…22 x Ie maximum (Ie maximum = maximum values of setting ranges) for T version |
| Magnetic release current per IEC | 416 A |
| Magnetic trip current, nom | 416 A |
| Mechanical life operations | 30000 /h |
| Number of poles | 3 |
| Overload release current setting | 23 A |
| Phase failure sensitive | true |
| Phase loss protection | Differential release |
| Pollution degree | 3 |
| Protection type | Adjustable thermal/fixed magnetic (13 x In) |
| Rated frequency | 45 Hz |
| Rated impulse withstand voltage (Uimp) | Main circuits (Uimp)/overvoltage category: 6 kV/III, 8 kV (disconnect) |
| Rated operating voltage | 230 A |
| Rated operational current (Ie) per IEC | 32 A |
| Rated operation power at AC-3, 230 V | 7.5 kw |
| Rated operation power at AC-3, 400 V | 15 kw |
| Rated permanent current Iu | 32 A |
| Rated service short circuit breaking capacity (Ics) per IEC | 6kA @ 690V AC |
| Rated short-circuit breaking capacity lcu at 400 V, AC | 65 kA |
| Rated supply current (Ie) | 6.3 A |
| Rated thermal current (Ith) | 6.3...45 A up to 60 °C (140 °F) ambient temperature |
| Shock | Transport (60068-2-27): 30 G/11 ms, OFF |
| Short circuit current for combination motor controller, max | 65kA @ 480V/277V, UL 60947-4-1 self-protected (Type E) |
| Short circuit current for combination motor controller with 100-C IEC contactor, max | 65 kA @ 480Y/277V, UL 60947-4-1-Type F |
| Short circuit current for group motor installation, max | 65kA @ 480V, UL 60947-4-1-manual motor controller |
| Short circuit current for group motor installation with 100-C IEC contactor, max | 65kA @ 480V, UL 60947-4-1-manual motor controller |
| Short circuit current for motor disconnect, max | 65kA @ 480V, UL 60947-4-1-manual motor controller |
| Short circuit current for motor disconnect with 100-C IEC contactor, max | 65kA @ 480V, UL 60947-4-1-manual motor controller |
| Short circuit current for self-protected combination motor controller with 100-C contactor, max | 65 kA @ 480Y/277V, UL 508-Type E |
| Short circuit current for tap conductor protection, max | 65 kA @ 480Y/277V, UL 60947-4-1-manual motor controller |
| Short circuit current (Icu) for group motor installation, max | 65kA @ 480V |
| Short circuit current (Type 2 coordination) with 100-C IEC contactor, max | 65kA @ 480V |
| Site altitude | to 2000 m N.N. (6561 ft) |
| Switching frequency, max | 25 ops/h |
| Switching of standard motors per IEC | 7.5 kW @ 230/240V (AC-3), 3-phase |
| Switch off technique | Thermomagnetic |
| Total power loss (Pv) for circuit breaker | 7…22 W @ rated load/operating temperature |
| Trip class | 10 |
| Type of control element | Turn button |
| Type of electrical connection of main circuit | Screw connection |
| Ultimate short circuit breaking capacity (Icu) per IEC | 65kA @ 440/460V AC |
| Vibration | ops (60068-2-6): 5 G |
| Weight | 782 lb |
| Width | 54 mm |
| With integrated auxiliary switch | false |
| With integrated under voltage release | false |
| With thermal protection | true |
More Rockwell Automation / Allen-Bradley parts
Available on requestRockwell Automation / Allen-Bradley 140M-C-WTN
Available on request140M-F8E-C25-XC Motor Protection Circuit-Breaker
Available on requestRockwell Automation / Allen-Bradley 140MG-G8P-B30 – 140MG 3A G Frame Motor Ckt Protector
Available on requestRockwell Automation / Allen-Bradley 140MG-G8P-B30-AA – 140G 125A G Frame Mtr Protection Ckt-Bkr
Available on requestRockwell Automation / Allen-Bradley 140MG-G8P-B30-AJ – 140G 125A G Frame Mtr Protection Ckt-Bkr
Available on requestRockwell Automation / Allen-Bradley 140MG-G8P-B30-AJ-MT – 140G 125A G Frame Mtr Protection Ckt-Bkr