Allen-Bradley – 140M-C2E-C16-KN-TE Motor Protection Circuit- Breaker
Discontinued by Rockwell Automation / Allen-Bradley — we can still source the original 140M-C2E-C16-KN-TE (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | 140M IEC Circuit Breakers |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
Can I still buy the 140M-C2E-C16-KN-TE now that it is discontinued?
Yes. Rockwell Automation / Allen-Bradley has discontinued the 140M-C2E-C16-KN-TE, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can 140M-C2E-C16-KN-TE be shipped?
140M-C2E-C16-KN-TE is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 140M-C2E-C16-KN-TE in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 140M-C2E-C16-KN-TE and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 140M-C2E-C16-KN-TE, subject to availability and destination.
Allen-Bradley 140M-C2E-C16-KN-TE — Motor Protection Circuit- Breaker. Discontinued by Rockwell Automation on March 03, 2022. PartnerPLC supplies new, surplus and discontinued Allen-Bradley parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Discontinued |
| Discontinued date | March 03, 2022 |
| Replacement category (Rockwell) | Functional Replacement |
| Repair options available | No |
Specifications
| Amperage Rating | 10 - 16A,MxRtg MCPs(no OvPrt)is 1200.0A |
| Ambient operating temperature | -25 °C |
| Ambient storage temperature | -40 °C |
| Ambient temperature compensation | -20 °C |
| Auxiliary circuits/overvoltage category-inv | 6kV/III @ rated impulse withstand voltage (Uimp) |
| Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC | No back-up fuse required @ 230/240V |
| Breaking capacity | Standard breaking capacity |
| Contactor size, min-inv | 100-K12: UL-508-Type F combination motor controller |
| Contactor size (Type 2 coordination), min-inv | 100-C30 @ 600V |
| Current range | 10...16 A |
| Degree of protection (IP) | IP2X |
| Dependence on temperature | No current reduction @ 60 °C-inv |
| Depth | 74.5 mm |
| Device construction | Built-in device fixed built-in technique |
| Dry heat | 100 °C, relative humidity < 50 %, 7 d (60086-2-2)-inv |
| Electrical life cycle | (Ie max.) 100000 ops |
| Factory option | UL508 Type E spacing module |
| Frame size | Frame size C, 32 A |
| Fuse or circuit breaker per NEC, max | 450 A, UL 508-manual motor controller |
| Fuse or circuit breaker rating per NEC, max | 450 A, UL 508-manual motor controller with 100-C contactor |
| Fuse or circuit breaker rating with 100-K contactor per NEC, max | 450 A, UL 508-manual motor controller |
| Height | 90 mm |
| Hp rating, max | 5Hp @ 230V, 3-phase |
| KW rating, max | 7.5 kW @ 415V (AC-3), 3-phase |
| Magnetic release current | Fixed setting 13...14 x Ie max. Ie max. = maximum values of setting ranges, (±20 %) |
| Magnetic release current per IEC | 208 A |
| Magnetic trip current | 208 A |
| Main circuits/overvoltage category | 6kV/III @ rated impulse withstand voltage (Uimp) |
| Mechanical life operations | 100000 /h |
| Moisture change climate | 23 °C/83 % relative humidity and 40 °C/92 % relative humidity, 56 cycles (600068-2-30)-inv |
| Moisture heat | 40 °C, relative humidity 93 %, 56 d (60068-2-3)-inv |
| Number of poles | 3 |
| Overload release current setting | 10 A |
| Phase failure sensitive | true |
| Phase loss protection | Differential release |
| Pollution degree | 3 |
| Protection type | Adjustable thermal/fixed magnetic (13 x In) |
| Rated frequency | 50/60 Hz |
| Rated operating voltage | 230 A |
| Rated operating voltage, max | 690V per IEC, SEV, VDE0660 |
| Rated operational current (Ie) per IEC | 16 A |
| Rated operation power at AC-3, 230 V | 4 kw |
| Rated operation power at AC-3, 400 V | 7.5 kw |
| Rated service short circuit breaking capacity (Ics) per IEC | 6kA @ 500V |
| Rated short-circuit breaking capacity lcu at 400 V, AC | 65 kA |
| Rated supply current | 0.1 A |
| Rated thermal current | 0.1...32A @ 60°C ambient temperature (Ith)-inv |
| Shock resistance | Transport (60068-2-27): 30 G, 11 ms, all axes |
| Short circuit current for combination motor controller, max | 30kA @ 480V/277V per UL 508-self-protected (Type E) |
| Short circuit current for combination motor controller with 100-C contactor, max-inv | 30 kA @ 480Y/277V, UL 508-Type F |
| Short circuit current for combination motor controller with 100-K contactor, max-inv | 30 kA @ 480Y/277V, UL 508-Type F |
| Short circuit current for group motor installation, max | 30kA @ 600V, UL 508-manual motor controller |
| Short circuit current for group motor installation with 100-C contactor, max-inv | 30kA @ 600V, UL 508-manual motor controller |
| Short circuit current for group motor installation with 100-K contactor, max-inv | 30kA @ 600V, UL 508-manual motor controller |
| Short circuit current for motor disconnect, max | 30kA @ 600V, UL 508-manual motor controller |
| Short circuit current for motor disconnect with 100-C contactor, max-inv | 30kA @ 480V, UL 508-manual motor controller |
| Short circuit current for motor disconnect with 100-K contactor, max-inv | 30kA @ 600V, UL 508-manual motor controller |
| Short circuit current for self-protected combination motor controller with 100-C contactor, max-inv | 30 kA @ 480Y/277V, UL 508-Type E |
| Short circuit current for tap conductor protection, max | 30 kA @ 480Y/277V per UL 508-manual motor controller |
| Short circuit current (Type 2 coordination), max-inv | 50kA @ 400V |
| Site altitude | To 2000 N.N.(m) |
| Switching frequency, max | 25 ops/h |
| Switching of standard motors per IEC | 7.5 kW @ 400/415V, 3-phase |
| Switch off technique | Thermomagnetic |
| Terminal type | Screw connection |
| Total power loss (Pv) for circuit breaker at rated load operating temperature-inv | 6 W |
| Trip class | 10 |
| Type of control element | Turn button |
| Type of electrical connection of main circuit | Screw connection |
| Ultimate short circuit breaking capacity (Icu) per IEC | 65kA @ 400/415V |
| Vibration resistance | ops (60068-2-6): 5 G |
| Weight | 317 lb |
| Width | 45 mm |
| With integrated auxiliary switch | false |
| With integrated under voltage release | false |
| With thermal protection | true |
More Rockwell Automation / Allen-Bradley parts
Available on requestRockwell Automation / Allen-Bradley 140M-C-W455N
Available on requestRockwell Automation / Allen-Bradley 140M-C-WBE – Feeder Block
Available on requestRockwell Automation / Allen-Bradley 140M-C-WTEN
Available on requestRockwell Automation / Allen-Bradley 140M-C-WTN
Available on request140M-F8E-C25-XC Motor Protection Circuit-Breaker
Available on requestRockwell Automation / Allen-Bradley 140MG-G8P-B30 – 140MG 3A G Frame Motor Ckt Protector