| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives. |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (690 V) 40 °C 145 A, (690 V) 55 °C 135 A, (690 V) 70 °C 115 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 96 A, (440 V) 55 °C 93 A, (500 V) 55 °C 80 A, (690 V) 55 °C 65 A, (1000 V) 55 °C 30 A, (380 / 400 V) 55 °C 96 A, (220 / 230 / 240 V) 55 °C 96 |
| Rated Operational Current DC-1 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 145 A, (110 V) 2 Poles in Series, 55 °C 135 A, (110 V) 2 Poles in Series, 70 °C 115 A, (110 V) 3 Poles in Series, 40 °C 145 A, (110 V) 3 Poles in Series, 55 °C 135 A, (110 V) 3 Poles in Series, 70 °C 115 A, (220 V) 3 Poles in Series, 40 °C 145 A, (220 V) 3 Poles in Series, 55 °C 135 A, (220 V) 3 Poles in Series, 70 °C 115 A |
| Rated Operational Current DC-3 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 145 A, (110 V) 2 Poles in Series, 55 °C 135 A, (110 V) 2 Poles in Series, 70 °C 115 A, (110 V) 3 Poles in Series, 40 °C 145 A, (110 V) 3 Poles in Series, 55 °C 135 A, (110 V) 3 Poles in Series, 70 °C 115 A, (220 V) 3 Poles in Series, 40 °C 145 A, (220 V) 3 Poles in Series, 55 °C 135 A, (220 V) 3 Poles in Series, 70 °C 115 A, (72 V) 1-Pole, 40 °C 130 A, (72 V) 1-Pole, 55 °C 130 A, (72 V) 1-Pole, 70 °C 115 A |
| Rated Operational Current DC-5 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 145 A, (110 V) 2 Poles in Series, 55 °C 135 A, (110 V) 2 Poles in Series, 70 °C 115 A, (110 V) 3 Poles in Series, 40 °C 145 A, (110 V) 3 Poles in Series, 55 °C 135 A, (110 V) 3 Poles in Series, 70 °C 115 A, (220 V) 3 Poles in Series, 40 °C 145 A, (220 V) 3 Poles in Series, 55 °C 135 A, (220 V) 3 Poles in Series, 70 °C 115 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 55 kW, (440 V) 55 kW, (500 V) 55 kW, (690 V) 55 kW, (1000 V) 40 kW, (380 / 400 V) 45 kW, (220 / 230 / 240 V) 25 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 160 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 300 cycles per hour |
| Mechanical Durability | 10 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 48 ... 130 V, 60 Hz 48 ... 130 V, DC Operation 48 ... 130 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A, Holding at Max. Rated Control Circuit Voltage DC 2 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 400 W |
| Power Loss | at Rated Operating Conditions per Pole 3.5 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 60 ... 130 ms, Between Coil De-energization and NO Contact Opening 55 ... 125 ms, Between Coil Energization and NC Contact Opening 27 ... 77 ms, Between Coil Energization and NO Contact Closing 30 ... 80 ms |
| Connecting Capacity Main Circuit | Bar 30 mm², Flexible with Cable End 2 x 6 ... 35 mm², Rigid 2 x 6 ... 65 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Bar 30 mm², Flexible with Cable End 1 x 10 ... 70 mm², Rigid 2 x 6 ... 65 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Connecting Terminals (delivered in open position) Main Poles | M8 hexagon socket screw with single connector |
| Tightening Torque | Main Circuit 8 N·m |
| Terminal Type | Cable Clamp |
| Product Name | Block Contactor |