ABB 1SBL911074R8301 – AX12-30-01-83 48V 50/60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| UPC / EAN | 3471522394835 |
Shipping & availability
When can 1SBL911074R8301 be shipped?
1SBL911074R8301 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL911074R8301 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL911074R8301 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL911074R8301, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL911074R8301 |
| Type | AX12-30-01-83 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 74 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 22 A, (690 V) 40 °C 25 A, (690 V) 70 °C 18 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 12 A, (440 V) 55 °C 9 A, (500 V) 55 °C 9 A, (690 V) 55 °C 7 A, (380 / 400 V) 55 °C 12 A, (220 / 230 / 240 V) 55 °C 12 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 5.5 kW, (440 V) 4 kW, (500 V) 5.5 kW, (690 V) 5.5 kW, (380 / 400 V) 5.5 kW, (220 / 230 / 240 V) 3 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 48 V, 60 Hz 48 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 8 V·A, Average Holding Value 50 Hz 8 V·A, Average Holding Value 60 Hz 8 V·A, Average Holding Value, from Warm State 2 W, Average Pull-in Value 50 Hz 70 V·A, Average Pull-in Value 60 Hz 80 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 0.8 W, at Rated Operating Conditions AC-3 per Pole 0.1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 25 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3/4 hp, (200 ... 208 V AC) Three Phase 3 hp, (220 ... 240 V AC) Three Phase 3, (240 V AC) Single Phase 2 hp, (440 ... 480 V AC) Three Phase 7.5 hp, (550 ... 600 V AC) Three Phase 10 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 9 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 13.8 A, (200 ... 208 V AC) Three Phase 11 A, (220 ... 240 V AC) Three Phase 9.6 A, (240 V AC) Single Phase 12 A, (440 ... 480 V AC) Three Phase 11 A, (550 ... 600 V AC) Three Phase 11 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 6d278905-0e08-45cb-bc72-46500d45fd95 Bulgaria |
| Simplified SCIP | 005919a1-d24d-4aee-86ab-0b4d27d3f547 Finland, 02501028-8fca-4fa9-a07c-1020efc17d73 Belgium, 1ad3d757-b73e-43cd-94d4-8c7deae6d89b Germany, 21a3a7c2-9029-4f2f-abeb-56cad0161ca9 Netherlands, 45d82c7f-d451-4d13-bff1-da306b33177c Hungary, 5a43926c-134f-48fe-a132-27d99a8b4c32 Spain, 683cfd44-157c-4568-97c0-e6db16a52363 Portugal, 6d32c396-25b1-4733-bf53-9d0d6644e4d7 Estonia, 79498efb-7da9-4371-a126-bad0cc11bb39 France, 7c68a93a-dbba-43d1-8a20-bb5c5ce0c399 Germany, 82712927-de9a-4798-bb94-6c7be15f66ec France, 8b03f4fe-e3de-4126-a788-31e6d3d2acf8 Poland, 8ca4f596-2a77-4966-9942-5c4470a84439 Croatia, 8d1d8283-0937-4610-a216-132d2c8494b3 Norway, 8dd475c2-1c6a-46b6-9cc2-3d88560c477b Germany, 8e312383-310a-4095-80d9-b5ca79caa3f9 Czechia, 912760e4-6293-4071-9c8d-21900c61ca11 Germany, 95153fa1-5a0e-42df-9d14-f0b744b39abd Poland, a444583b-bdac-4149-af0b-bea74793e702 Greece, c67b5dbb-e652-43d0-b780-75827b8b7ef5 Belgium, c6a82e42-504f-4217-8f6f-57669a03dff4 Poland, cd619957-f39a-4179-b1aa-962e36d526a7 Denmark, d1cc4c1e-49b1-4a00-8d8f-85ec82be4e1e Sweden, edb2b28c-0ec5-48ba-b6ee-b69ea5dbd439 Germany, f1018ec5-397a-4938-b4a0-aed6f7da1f62 Hungary, fa0c46b6-3e54-4ec7-8e9b-f3ca355bb4a9 Sweden, fd6ea5be-0935-4f9d-a223-3fa6533cfe45 Italy |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX12-30-01-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX12-30-10-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX12-30-01-81 24V 50/60Hz Contactor
Available on requestAX12-30-10-81 24V 50/60Hz Contactor
Available on requestAX12-30-10-83 48V 50/60Hz Contactor
Available on requestAX12-30-01-84 110V50Hz/110-120V60Hz Contactor
Available on requestAX12-30-10-84 110V50Hz/110-120V60Hz Contactor
Available on requestAX12-30-01-85 380-400V50Hz/400V-415V60Hz Contactor