| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| Country of origin | India |
| UPC / EAN | 3471522394811 |
Shipping & availability
When can 1SBL911074R8101 be shipped?
1SBL911074R8101 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL911074R8101 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL911074R8101 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL911074R8101, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL911074R8101 |
| Type | AX12-30-01-81 |
| Lifecycle | Active (current ABB product) |
| Country of origin | India |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 74 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 22 A, (690 V) 40 °C 25 A, (690 V) 70 °C 18 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 12 A, (440 V) 55 °C 9 A, (500 V) 55 °C 9 A, (690 V) 55 °C 7 A, (380 / 400 V) 55 °C 12 A, (220 / 230 / 240 V) 55 °C 12 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 5.5 kW, (440 V) 4 kW, (500 V) 5.5 kW, (690 V) 5.5 kW, (380 / 400 V) 5.5 kW, (220 / 230 / 240 V) 3 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 24 V, 60 Hz 24 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 8 V·A, Average Holding Value 50 Hz 8 V·A, Average Holding Value 60 Hz 8 V·A, Average Holding Value, from Warm State 2 W, Average Pull-in Value 50 Hz 70 V·A, Average Pull-in Value 60 Hz 80 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 0.8 W, at Rated Operating Conditions AC-3 per Pole 0.1 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 25 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3/4 hp, (200 ... 208 V AC) Three Phase 3 hp, (220 ... 240 V AC) Three Phase 3, (240 V AC) Single Phase 2 hp, (440 ... 480 V AC) Three Phase 7.5 hp, (550 ... 600 V AC) Three Phase 10 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 9 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 13.8 A, (200 ... 208 V AC) Three Phase 11 A, (220 ... 240 V AC) Three Phase 9.6 A, (240 V AC) Single Phase 12 A, (440 ... 480 V AC) Three Phase 11 A, (550 ... 600 V AC) Three Phase 11 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | bdb40efd-cc3b-49af-85e3-1a2a7a12efd3 Bulgaria |
| Simplified SCIP | 185b8cc4-3a03-4795-b6f1-53c8a57060be Portugal, 1ea152e7-687a-4e3d-bb83-61a77e291f58 Hungary, 59eea28e-2fbf-4081-a2fe-affb1ebb19f1 Denmark, 62a08d48-37d4-4905-b632-a0d2d1160e27 Spain, 6688527b-b9f7-4bef-8180-691d0ee75c3a Croatia, 69acf3f5-025c-4fec-b57b-6f261f02ae11 Italy, 6ab485ce-2966-4de7-b573-daa9bf39c6a2 Germany, 6cfa41f6-5259-44be-9d55-a1a5913f7d0e Norway, 6f10765f-6391-4cbb-af35-30de0952e21f Poland, 6fa08d5d-bd34-4457-8cbd-535256507bee Belgium, 7eaddc26-443f-4248-ae03-58ffd87e141d Germany, 83dd5400-ac65-45ee-934d-0fed95d259cd Hungary, 840d9b12-6639-44e1-b040-65e5f86eb66a France, 884ef686-dc6e-49e6-8349-908132e7e4b6 France, adcfb4cb-57d8-4214-b2f9-a5cb1de7d403 Estonia, bb5ec3d9-f6db-4172-922a-93e6adb57b4c Germany, bbc2cad4-8ee3-4538-b52e-a4cf6c681fad Germany, c8bc8359-f9c6-4849-802a-c31df2edda49 Netherlands, c8ea8e4d-8825-4be0-8df1-ae81caabf131 Belgium, d19b228e-03fb-453e-b4f2-eaa3af1c31ac Germany, e3cb1741-12cd-4900-9f64-5e8a5351dded Finland, e6c3129a-6eba-496b-aa25-d96f7d0da5c9 Czechia, f0d5f6d2-7bb6-47ff-9fd8-e6e9fd37116d Greece, f25cd1b3-ecd5-4458-b0bd-5e262a6edbcb Sweden, f5aac1ef-d4a2-4c21-b603-0ec69435b08a Poland, f7a3ae24-54ac-4160-9e6d-ae1db5759830 Poland, f9fc70a0-ae95-44d6-be60-b9623863e3f6 Sweden |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707310 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX12-30-01-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX12-30-10-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX12-30-01-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX12-30-10-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX12-30-10-81 24V 50/60Hz Contactor
Available on requestAX12-30-01-83 48V 50/60Hz Contactor
Available on requestAX12-30-10-83 48V 50/60Hz Contactor
Available on requestAX12-30-01-84 110V50Hz/110-120V60Hz Contactor