ABB 1SBL321074R3610 – AX40-30-10-36 190V50Hz/220V60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.667 kg |
| UPC / EAN | 3471522401366 |
Shipping & availability
When can 1SBL321074R3610 be shipped?
1SBL321074R3610 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL321074R3610 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL321074R3610 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL321074R3610, subject to availability and destination.
AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL321074R3610 |
| Type | AX40-30-10-36 |
| Lifecycle | Active (current ABB product) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 54 mm |
| Product Net Depth / Length | 90 mm |
| Product Net Height | 108.3 mm |
| Product Net Weight | 0.667 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 65 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 60 A, (690 V) 40 °C 60 A, (690 V) 70 °C 42 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 40 A, (440 V) 55 °C 37 A, (500 V) 55 °C 33 A, (690 V) 55 °C 25 A, (380 / 400 V) 55 °C 40 A, (220 / 230 / 240 V) 55 °C 40 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 0.55 A / 60 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 18.5 kW, (440 V) 22 kW, (500 V) 22 kW, (690 V) 22 kW, (380 / 400 V) 18.5 kW, (220 / 230 / 240 V) 11 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 190 V, 60 Hz 220 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A, Average Holding Value 50 Hz 12 V·A, Average Holding Value 60 Hz 12 V·A, Average Holding Value, from Warm State 3 W, Average Pull-in Value 50 Hz 120 V·A, Average Pull-in Value 60 Hz 140 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 3 W, at Rated Operating Conditions AC-3 per Pole 1.3 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 7 ... 14 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 6 ... 18 ms, Between Coil Energization and NO Contact Closing 8 ... 21 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 2.3 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 60 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3 hp, (200 ... 208 V AC) Three Phase 10 hp, (220 ... 240 V AC) Three Phase 15, (240 V AC) Single Phase 7.5 hp, (440 ... 480 V AC) Three Phase 30 hp, (550 ... 600 V AC) Three Phase 40 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 20 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 34 A, (200 ... 208 V AC) Three Phase 32.2 A, (220 ... 240 V AC) Three Phase 42 A, (240 V AC) Single Phase 40 A, (440 ... 480 V AC) Three Phase 40 A, (550 ... 600 V AC) Three Phase 41 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 4bac180c-c443-42fc-b432-740c650c9e83 Bulgaria |
| Simplified SCIP | 09c5472a-4552-4142-b920-ce2baefdfb5a Italy, 113c4166-4b6c-4fd1-8326-9bbe16bfd04f Poland, 31c26155-0a8a-4155-9503-6c5a52d435ad Norway, 3edb4b99-9428-4b0b-abe7-ddf5d65d5b5a Germany, 46bb06b9-2890-4894-a6d2-c3b5955e2c1e Netherlands, 47c07abe-22b2-4d0e-8136-e84e43bdb9c9 Portugal, 485ea146-9e91-47c9-8ade-ea98a9ffbc7f Sweden, 48df9d50-73be-4463-9416-1ab3601b8f01 Czechia, 4c52de7f-0a57-49b4-b0ef-dfae138ba436 Sweden, 68fe82dc-1493-40bd-b074-914f60232399 Croatia, 7456a31d-3a59-4044-97da-81597013a786 Germany, 74a6fbc3-e415-4fc7-9e54-85640f360141 Estonia, 7f1c7b67-167b-49e0-89e6-8565e44cf4fd Poland, 7f9a4eb2-912a-426d-9127-db5c5f23497f Germany, 82e1f444-13e6-404b-b968-62e16f4a9bd6 Finland, 94784979-47d9-4d4d-aa70-3bd11400dddb Denmark, 9958bc2e-0303-45e1-99c2-d47b62fd8d6e France, 9dc36642-630a-4c4c-b0a1-1751d82ea197 Hungary, a049bc5b-4ec5-4699-8de6-a38dc2876482 France, b96ec4ca-99aa-4d87-a174-20396fd78171 Spain, c2008317-79c4-4089-bea0-9909be2aa9cf Hungary, cc1da468-0fb5-4019-bf89-0108748b3abf Belgium, ec494f6b-0afa-41e1-8ae0-feba0977204a Greece, ec7e9aba-a68f-4bb7-b394-ce710783cfad Belgium, f1a3e56e-63ea-4609-abf8-f1345c9ffac0 Germany, f819437f-c21e-41c4-bd9c-678af65b7faf Poland, fc013c46-f5e6-4138-bee9-f61f8466f6a2 Germany |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestA40-30-01 220-230V 50Hz / 230-240V 60Hz / RC5-1 Contactor
Available on requestAX40-30-01-26 110-127V60HZ/105V50HZ Contactor
Available on requestAX40-30-10-26 110-127V60HZ/105V50HZ Contactor
Available on requestAX40-30-01-36 190V50Hz/220V60Hz Contactor
Available on requestAX40-30-01-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX40-30-10-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX40-30-01-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX40-30-10-80 220-230V50Hz/230-240V60Hz Contactor