Siemens 3RV2011-0JA10

Circuit Protection & Switching

MPN
3RV2011-0JA10
€37.10excl. VAT & shipping
In stock — 8 available·Ships within 1 business day
Need a larger quantity or a formal quote?
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

What happens next
  1. We check stock, condition and lead time
  2. You get a written quote by email
  3. Approve it and we ship — in-stock parts within 1 business day

Have spare Siemens parts? We buy surplus →

What is the Siemens 3RV2011-0JA10?

Circuit Protection & Switching

Specifications

General technical data

Technical Product Detail Pagehttps://i.siemens.com/1P3RV2011-0JA10
Product equipment of circuit breaker for motor protection complete unit with protection deviceYes
size of the circuit-breakerS00
size of contactor can be combined company-specificS00, S0
product function disconnector functionalityYes
product extension auxiliary switchYes
power loss [W] for rated value of the current — at AC in hot operating state7.25 W
power loss [W] for rated value of the current — at AC in hot operating state per pole2.4 W
type of calculation of power loss current-dependentquadratic
insulation voltage with degree of pollution 3 at AC rated value690 V
surge voltage resistance rated value6 kV
maximum permissible voltage for protective separation — in networks with ungrounded star point between main and auxiliary circuit400 V
maximum permissible voltage for protective separation — in networks with grounded star point between main and auxiliary circuit400 V
protection class IP — on the front according to IEC 60529IP20
protection class IP — on the frontIP20
protection class IP — of the terminalIP20
shock resistance according to IEC 60068-2-2725g / 11 ms
mechanical service life (operating cycles) — of the main contacts typical100 000
mechanical service life (operating cycles) — of auxiliary contacts typical100 000
electrical endurance (operating cycles) typical100 000
reference code according to IEC 81346-2Q
continuous current rated value1 A
Substance Prohibitance (day/month/year)10/01/2009
Net Weight316.6 g

Ambient conditions

installation altitude at height above sea level maximum2 000 m
ambient temperature — during operation-20 ... +60 °C
ambient temperature — during storage-50 ... +80 °C
ambient temperature — during transport-50 ... +80 °C
temperature compensation-20 ... +60 °C
relative humidity during operation10 ... 95 %

Main circuit

number of poles for main current circuit3
adjustable current response value current of the current-dependent overload release0.7 ... 1 A
type of voltage for main current circuitAC
operating voltage — rated value690 V
operating voltage — rated value20 ... 690 V
operating voltage — at AC-3 rated value maximum690 V
operating voltage — at AC-3e rated value maximum690 V
operating frequency rated value50 ... 60 Hz
operational current rated value1 A
operational current — at AC-3 at 400 V rated value1 A
operational current — at AC-3e at 400 V rated value1 A
— at 230 V rated value0.2 kW
— at 400 V rated value0.25 kW
— at 500 V rated value0.4 kW
— at 690 V rated value0.6 kW
— at 230 V rated value0.2 kW
— at 400 V rated value0.25 kW
— at 500 V rated value0.4 kW
— at 690 V rated value0.6 kW
operating frequency — at AC-3 maximum15 1/h
operating frequency — at AC-3e maximum15 1/h

Auxiliary circuit

type of voltage for auxiliary and control circuitAC/DC
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
number of CO contacts for auxiliary contacts0

Protective and monitoring functions

product function — ground fault detectionNo
product function — phase failure detectionYes
trip classCLASS 10
design of the overload releasethermal
protection function thermal overload protection (ANSI 49)Yes
maximum short-circuit current breaking capacity (Icu) — at AC at 240 V rated value100 kA
maximum short-circuit current breaking capacity (Icu) — at AC at 400 V rated value100 kA
maximum short-circuit current breaking capacity (Icu) — at AC at 500 V rated value100 kA
maximum short-circuit current breaking capacity (Icu) — at AC at 690 V rated value100 kA
operating short-circuit current breaking capacity (Ics) at AC — at 240 V rated value100 kA
operating short-circuit current breaking capacity (Ics) at AC — at 400 V rated value100 kA
operating short-circuit current breaking capacity (Ics) at AC — at 500 V rated value100 kA
operating short-circuit current breaking capacity (Ics) at AC — at 690 V rated value100 kA
response value current of instantaneous short-circuit trip unit13 A

UL/CSA ratings

full-load current (FLA) for 3-phase AC motor — at 480 V rated value1 A
full-load current (FLA) for 3-phase AC motor — at 600 V rated value1 A
— at 575/600 V rated value0.5 hp
UL File Number (CCN)E47705 (NLRV, NLRV7), E156943 (NKJH, NKJH7)

Short-circuit protection

product function short circuit protectionYes
design of the short-circuit tripmagnetic
design of the fuse link for IT network for short-circuit protection of the main circuit — at 500 VgL/gG 10 A
design of the fuse link for IT network for short-circuit protection of the main circuit — at 690 VgL/gG 10 A
certificate of suitability according to ATEX directive 2014/34/EUDMT 02 ATEX F 001
type of protection according to ATEX directive 2014/34/EUEx II (2) GD

Installation/ mounting/ dimensions

mounting positionany
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Mounting method of circuit breaker for Transformer protection, Generator protection and system protection optional standard bar mountingYes
height97 mm
width45 mm
depth97 mm
— forwards0 mm
— backwards0 mm
— upwards50 mm
— downwards50 mm
— at the side0 mm
— forwards0 mm
— backwards0 mm
— upwards50 mm
— at the side30 mm
— downwards50 mm
— forwards0 mm
— backwards0 mm
— upwards50 mm
— downwards50 mm
— at the side30 mm
— downwards30 mm
— upwards30 mm
— at the side9 mm
— downwards30 mm
— upwards30 mm
— at the side9 mm
— downwards30 mm
— upwards30 mm
— at the side9 mm
— downwards30 mm
— upwards30 mm
— at the side9 mm
— downwards50 mm
— upwards50 mm
— backwards0 mm
— at the side30 mm
— forwards0 mm
— downwards50 mm
— upwards50 mm
— backwards0 mm
— at the side30 mm
— forwards0 mm

Connections/ Terminals

product component removable terminal for auxiliary and control circuitNo
type of electrical connection — for main current circuitscrew-type terminals
arrangement of electrical connectors for main current circuitTop and bottom
— solid or stranded2x (0,75 ... 2,5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for AWG cables for main contacts2x (18 ... 14), 2x 12
connectable conductor cross-section for main contacts — solid or stranded0.75 ... 4 mm²
connectable conductor cross-section for main contacts — finely stranded with core end processing0.5 ... 2.5 mm²
AWG number as coded connectable conductor cross section for main contacts18 ... 12
tightening torque — for main contacts with screw-type terminals0.8 ... 1.2 N·m
design of screwdriver shaftDiameter 5 to 6 mm
size of the screwdriver tipPozidriv size 2
design of the thread of the connection screw — for main contactsM3

Safety related data

product function suitable for safety functionYes
suitability for use — safety-related switching onNo
suitability for use — safety-related switching OFFYes
service life maximum10 a
test wear-related service life necessaryYes
proportion of dangerous failures — with low demand rate according to SN 3192040 %
proportion of dangerous failures — with high demand rate according to SN 3192050 %
B10 value with high demand rate according to SN 319205 000
failure rate [FIT] with low demand rate according to SN 3192050 FIT
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
safety device type according to IEC 61508-2Type A
T1 value — for proof test interval or service life according to IEC 6150810 a
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front

Display

display version for switching statusHandle

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

3RV2011-0JA10: frequently asked questions

When can 3RV2011-0JA10 be shipped?

3RV2011-0JA10 is in stock and typically ships within 1 business day via UPS, DHL or FedEx, worldwide.

Can I pick up 3RV2011-0JA10 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — alongside standard UPS, DHL and FedEx shipping, express (next-day) delivery is available at checkout for in-stock items like 3RV2011-0JA10.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3RV2011-0JA10, subject to availability and destination.

More Siemens parts

Siemens QBM2030-5New
Siemens
QBM2030-5
€104.94excl. VAT
In stock
Siemens 3RV2011-0JA10€37.10