MAX Parts

Showing 49–72 of 77 parts

Compare MAX

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNPressure pipe/End capPosition (F.S.)Communication interfacePIN assignmentWire length
MAX48N-22V10AC024010 mm / Flat0 mm ... 240 mm 1)Analog1=V DC; 2=n.c.; 3=GND; 4=SIG80 mm
MAX48N-12A10K4030010 mm / Flat0 mm ... 300 mm 1)Analog——
MAX48A-32V10GC040010 mm / Flat0 mm ... 400 mm 1)Analog1=V DC; 2=n.c.; 3=GND; 4=SIG80 mm
MAX48N-32V10K8035010 mm / Flat0 mm ... 350 mm 1)Analog——
MAX48N-22A10AA072510 mm / Flat0 mm ... 725 mm 1)Analog1=V DC; 2=n.c.; 3=GND; 4=SIG60 mm
MAX48A-32A10HE210010 mm / Flat0 mm ... 2,100 mm 1)Analog1=V DC; 2=SIG; 3=GND; 4=n.c.100 mm
MAX48A-12A10GC025010 mm / Flat0 mm ... 250 mm 1)Analog1=V DC; 2=n.c.; 3=GND; 4=SIG80 mm
MAX48N-12C7FCE015010 mm / Flat0 mm ... 150 mm 1)CANopen1=n.c.; 2=V DC; 3=GND; 4=CAN_H; 5=CAN_L100 mm
MAX48N-22A10BE022010 mm / Flat0 mm ... 220 mm 1)Analog1=V DC; 2=SIG; 3=GND; 4=n.c.100 mm
MAX48N-12C7FCP039010 mm / Flat0 mm ... 390 mm 1)CANopen1=n.c.; 2=V DC; 3=GND; 4=CAN_H; 5=CAN_L240 mm
MAX48N-32A10MC150010 mm / Flat0 mm ... 1,500 mm 1)Analog1=n.c.; 2=V DC; 3=GND; 4=SIG80 mm
MAX48N-12V10BE030010 mm / Flat0 mm ... 300 mm 1)Analog1=V DC; 2=SIG; 3=GND; 4=n.c.100 mm
MAX30N-92V10HA01057 mm / Flat0 mm ... 105 mm 1)Analog1=V DC; 2=SIG; 3=GND; 4=n.c.60 mm
MAX48N-12A10MP025010 mm / Flat0 mm ... 250 mm 1)Analog1=n.c.; 2=V DC; 3=GND; 4=SIG240 mm
MAX30N-72C11CA0200Flat0 mm ... 200 mm 1)CANopen1=n.c.; 2=V DC; 3=GND; 4=CAN_H; 5=CAN_L60 mm
MAX48N-32V20K2015710 mm / Flat0 mm ... 157 mm 1)Analog——
MAX48N-32A10MG050010 mm / Flat0 mm ... 500 mm 1)Analog1=n.c.; 2=V DC; 3=GND; 4=SIG120 mm
MAX48N-12V20K1035010 mm / Flat0 mm ... 350 mm 1)Analog——
MAX30N-72A10K804107 mm / Flat0 mm ... 410 mm 1)Analog——
MAX30N-72PBDBE05007 mm / Flat0 mm ... 500 mm 1)PWM1=V DC; 2=SIG; 3=GND; 4=n.c.100 mm
MAX48N-32JFDCE070010 mm / Flat0 mm ... 700 mm 1)SAE J19391=n.c.; 2=V DC; 3=GND; 4=CAN_H; 5=CAN_L100 mm
MAX48N-12JFDDC015710 mm / Flat0 mm ... 157 mm 1)SAE J19391=V DC; 2=n.c.; 3=GND; 4=CAN_H; 5=CAN_L80 mm
MAX48A-32A10ED006510 mm / Flat0 mm ... 65 mm 1)Analog1=n.c.; 2=V DC; 3=GND; 4=SIG90 mm
MAX48N-12C7FCE025010 mm / Flat0 mm ... 250 mm 1)CANopen1=n.c.; 2=V DC; 3=GND; 4=CAN_H; 5=CAN_L100 mm

Common to all listed parts

Items suppliedAccessories not included with delivery, please order separately.
MTTFD (mean time to dangerous failure)69Â years (ENÂ ISOÂ 13849-1)Â 1)
Fluid temperature–30 °C ... +95 °C 2)
Air humidity90Â % (Condensation not permitted)
Supply voltage24Â VÂ DC (8Â ... 32Â VÂ DC)
Switch-on time<Â 250Â ms
Hysteresis± 0,1 mm
RepeatabilityTyp. ± 0.2 mm