MAX Parts

Showing 25–48 of 77 parts

Compare MAX

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNPosition (F.S.)Damping zoneSwitch-on currentCurrent consumptionWire length
MAX48N-32V41K903500 mm ... 350 mm 1)63 mmTyp. 5.0 A / 50 µs≤ 30 mA—
MAX48A-11V10K100510 mm ... 51 mm 1)30 mmTyp. 2.5 A/ 50 µs≤ 60 mA—
MAX48N-12V30K105000 mm ... 500 mm 1)30 mmTyp. 5.0 A / 50 µs≤ 30 mA—
MAX48N-12A10AC01500 mm ... 150 mm 1)30 mmTyp. 5.0 A / 50 µs≤ 50 mA80 mm
MAX48N-32C01CP13750 mm ... 1,375 mm 1)63 mmTyp. 5.0 A / 50 µs≤ 30 mA240 mm
MAX48A-32C7FFE19600 mm ... 1,960 mm 1)63 mmTyp. 5.0 A / 50 µs≤ 30 mA100 mm
MAX30N-72A10AA01050 mm ... 105 mm 1)30 mm2,5 A/ 50 µs≤ 50 mA60 mm
MAX48A-12A10K402200 mm ... 220 mm 1)30 mmTyp. 5.0 A / 50 µs≤ 50 mA—
MAX48N-22A10AF14200 mm ... 1,420 mm 1)36 mmTyp. 5.0 A / 50 µs≤ 50 mA110 mm
MAX48A-22C7FFE06350 mm ... 635 mm 1)36 mmTyp. 5.0 A / 50 µs≤ 30 mA100 mm
MAX30N-72A10BA07000 mm ... 700 mm 1)30 mm2,5 A/ 50 µs≤ 50 mA80 mm
MAX48N-12V20K105000 mm ... 500 mm 1)30 mmTyp. 5.0 A / 50 µs≤ 30 mA—
MAX48N-22A10K510300 mm ... 1,030 mm 1)36 mmTyp. 5.0 A / 50 µs≤ 50 mA—
MAX48N-32A10AG05000 mm ... 500 mm 1)63 mmTyp. 5.0 A / 50 µs≤ 50 mA120 mm
MAX30N-82A10K703100 mm ... 310 mm 1)36 mm2,5 A/ 50 µs≤ 30 mA—
MAX30N-72V30AA03400 mm ... 340 mm 1)30 mmTyp. 5.0 A / 50 µs≤ 30 mA60 mm
MAX48A-32V20GC04000 mm ... 400 mm 1)63 mmTyp. 5.0 A / 50 µs≤ 30 mA80 mm
MAX48A-12A10GP01050 mm ... 105 mm 1)30 mmTyp. 5.0 A / 50 µs≤ 50 mA240 mm
MAX30N-72V30AA03200 mm ... 320 mm 1)30 mmTyp. 5.0 A / 50 µs≤ 30 mA60 mm
MAX48N-12C7FCP04200 mm ... 420 mm 1)30 mmTyp. 5.0 A / 50 µs≤ 30 mA240 mm
MAX48N-32A11BP03500 mm ... 350 mm 1)63 mmTyp. 5.0 A / 50 µs≤ 50 mA240 mm
MAX30N-92V10HA02850 mm ... 285 mm 1)63 mm5,0 A/ 50 µs≤ 30 mA60 mm
MAX48N-12V20AE03000 mm ... 300 mm 1)30 mmTyp. 5.0 A / 50 µs≤ 30 mA100 mm
MAX48N-32V20K607670 mm ... 767 mm 1)63 mmTyp. 5.0 A / 50 µs≤ 30 mA—

Common to all listed parts

Items suppliedAccessories not included with delivery, please order separately.
MTTFD (mean time to dangerous failure)69Â years (ENÂ ISOÂ 13849-1)Â 1)
Fluid temperature–30 °C ... +95 °C 2)
Air humidity90Â % (Condensation not permitted)
Switch-on time<Â 250Â ms
Hysteresis± 0,1 mm
RepeatabilityTyp. ± 0.2 mm
LinearityTyp. ± 0.25 mm (measuring range 50 to 500 mm) 3)