3VA Molded Case Circuit Breakers up to 2000 A, UL / IEC Parts

Showing 241–264 of 1,635 partsPage 11 of 69
Siemens 3VA5180-1MU31-0AA0 – Circuit breaker 3VA5 UL frame 125 3-poleAvailable on requestSiemens 3VA5180-1MU31-0AA0 – Circuit breaker 3VA5 UL frame 125 3-pole
MPN: 3VA5180-1MU31-0AA0 · Siemens
Price on request
Request a quote
Siemens 3VA5180-1MH31-0AA0 – Circuit breaker 3VA5 UL frame 125 3-poleAvailable on requestSiemens 3VA5180-1MH31-0AA0 – Circuit breaker 3VA5 UL frame 125 3-pole
MPN: 3VA5180-1MH31-0AA0 · Siemens
Price on request
Request a quote

Compare 3VA Molded Case Circuit Breakers up to 2000 A, UL / IEC

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNproduct designation / according to UL filepower loss [W] / maximumNet Weightadjustable response value setting current (Ii) / for I-tripping — minimumadjustable response value setting current (Ii) / for I-tripping — maximum
3VA6440-7JT31-0AA0CLAE70 W5.3 kg600 A4 800 A
3VA6440-7JP31-2AA0CLAE70 W5.3 kg600 A4 800 A
3VA6440-7JP31-0AA0CLAE70 W5.3 kg600 A4 800 A
3VA6440-7HN41-2AA0CLAE70 W6.9 kg4 800 A4 800 A
3VA5220-5GF41-0AA0MFAS43 W2.7 kg1 000 A2 000 A
3VA5180-4ED21-1AA0SEAM12.86 W660 g800 A800 A
3VA5180-4ED21-0AA0SEAS12.86 W1.2 g800 A800 A
3VA5180-1MU31-0AA0HEAP14.2 W953 g240 A560 A
3VA5180-1MH31-0AA0HEAP14.2 W953 g400 A960 A
3VA5170-6EF31-0AA0HEAS18.3 W950 g350 A700 A
3VA5320-5EC31-0AA0MJAS38 W4.767 kg1 250 A2 500 A
3VA5295-7ED61-0AA0CFAS3.4 W2 100 g400 A400 A
3VA5295-7ED36-1AA0CFAM5.1 W2 100 g400 A400 A
3VA5290-7ED61-0AA0CFAS16 W1.9 kg900 A900 A
3VA5290-7ED41-2AA0CFAS25 W2 800 g900 A900 A
3VA5290-7ED41-0AA0CFAS25 W2.7 kg900 A900 A
3VA5195-4EF41-0AA0SEAS10.6 W952 g150 A300 A
3VA6225-5KL31-2AA0MFAE42 W2.222 kg375 A2 500 A
3VA6225-5KL31-0AA0MFAE42 W2.5 kg375 A2 500 A
3VA6225-5JT41-2AA0MFAE42 W2.9 kg375 A2 500 A
3VA6225-5JT41-0AA0MFAE42 W3.2 kg375 A2 500 A
3VA6225-7JT31-0AA0CFAE42 W2.5 kg375 A2 500 A
3VA5580-7EC32-2AA0CMAS210 W12.76 kg4 000 A8 000 A
3VA5580-0MH36-0AA0HMAP210 W17.66 kg4 800 A9 600 A

Common to all listed parts

product designationMolded-case circuit breaker
design of the load switch / according to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type)Yes
product component — undervoltage releaseNo
product component — voltage triggerNo
product component — trip indicatorNo
number of CO contacts / for auxiliary contacts0
protection class IP / on the frontIP40
ambient temperature — during operation / minimum-25 °C