3VA Molded Case Circuit Breakers up to 1600 A, IEC Parts

Showing 505–528 of 3,031 parts
Siemens 3VA2563-6HL32-0AA0 – Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class H Icu=85 kA @ 415 V 3-pole
Siemens
3VA2563-6HL32-0AA0

Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class…

Siemens 3VA2563-6HK42-0AA0 – Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class H Icu=85 kA @ 415 V 4-pole
Siemens
3VA2563-6HK42-0AA0

Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class…

Siemens 3VA2563-6HK32-0AA0 – Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class H Icu=85 kA @ 415 V 3-pole
Siemens
3VA2563-6HK32-0AA0

Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class…

Siemens 3VA2710-3.E35-.... – Draw-out molded case circuit breaker with guide frame and PSS frame 1600
Siemens
3VA2710-3.E35-....

Draw-out molded case circuit breaker with guide frame and…

Siemens 3VA2710-3.E32-.... – Draw-out molded case circuit breaker with guide frame and PSS frame 1600
Siemens
3VA2710-3.E32-....

Draw-out molded case circuit breaker with guide frame and…

Siemens 3VA2710-3.E31-.... – Draw-out molded case circuit breaker with guide frame and PSS frame 1600
Siemens
3VA2710-3.E31-....

Draw-out molded case circuit breaker with guide frame and…

Siemens 3VA2710-3.E30-.... – Draw-out molded case circuit breaker without guide frame frame 1600; with RTC and 4AUX trip alarm switch S24
Siemens
3VA2710-3.E30-....

Draw-out molded case circuit breaker without guide frame…

Siemens 3VA2710-3.E26-.... – Fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24
Siemens
3VA2710-3.E26-....

Fixed-mounted molded case circuit breaker frame 1600

Siemens 3VA2710-3.E25-.... – Fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24
Siemens
3VA2710-3.E25-....

Fixed-mounted molded case circuit breaker frame 1600

Siemens 3VA2710-3.E23-.... – Fixed-mounted molded case circuit breaker frame 1600; with RTC and 4AUX trip alarm switch S24
Siemens
3VA2710-3.E23-....

Fixed-mounted molded case circuit breaker frame 1600

Siemens 3VA2710-1.D57-.... – Draw-out molded case circuit breaker with guide frame and PSS frame 1600
Siemens
3VA2710-1.D57-....

Draw-out molded case circuit breaker with guide frame and…

Siemens 3VA2710-1.D50-.... – Draw-out molded case circuit breaker without guide frame frame 1600; with RTC and 4AUX trip alarm switch S24
Siemens
3VA2710-1.D50-....

Draw-out molded case circuit breaker without guide frame…

Siemens 3VA2710-1.D47-.... – Draw-out molded case circuit breaker with guide frame and PSS frame 1600
Siemens
3VA2710-1.D47-....

Draw-out molded case circuit breaker with guide frame and…

Siemens 3VA2710-1.D46-.... – Draw-out molded case circuit breaker with guide frame and PSS frame 1600
Siemens
3VA2710-1.D46-....

Draw-out molded case circuit breaker with guide frame and…

Siemens 3VA2612-6HL42-0AA0 – Circuit breaker 3VA2 IEC Frame 1250 breaking capacity class H Icu=85 kA @ 415 V 4-pole, line protection ETU320
Siemens
3VA2612-6HL42-0AA0

Circuit breaker 3VA2 IEC Frame 1250 breaking capacity class…

Siemens 3VA2580-7KQ42-0AA0 – Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class C Icu=110 kA @ 415 V 4-pole
Siemens
3VA2580-7KQ42-0AA0

Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class…

Siemens 3VA2580-7KQ32-0AA0 – Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class C Icu=110 kA @ 415 V 3-pole
Siemens
3VA2580-7KQ32-0AA0

Circuit breaker 3VA2 IEC Frame 1000 breaking capacity class…

Compare 3VA Molded Case Circuit Breakers up to 1600 A, IEC

Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.

MPNdesign of the overcurrent releaseNet Weightadjustable response value setting current (Ii) / for I-tripping — minimumadjustable setting current (InN) / for N-tripping — minimumadjustable setting current (InN) / for N-tripping — maximum
3VA2563-6HL32-0AA0ETU32013.068 kg945 A0 A0 A
3VA2563-6HK42-0AA0ETU34015.42 kg7 560 A125 A630 A
3VA2563-6HK32-0AA0ETU34011.34 kg7 560 A——
3VA2612-6HL42-0AA0ETU32028.24 kg1 875 A250 A1 250 A
3VA2580-7KQ42-0AA0ETU86018.16 kg1 200 A160 A800 A
3VA2580-7KQ32-0AA0ETU86013.52 kg1 200 A160 A1 280 A

Common to all listed parts

product designationMolded case circuit breaker
design of the productLine protection
insulation voltage / rated value800 V
operating voltage / at AC / rated value690 V
mechanical service life (operating cycles) / typical10 000
electrical endurance (operating cycles) / at AC-1 / at 380/415 V4 600
electrical endurance (operating cycles) / at AC-1 / at 690 V3 200
maximum short-circuit current breaking capacity (Icu) — at 690 V35 kA